Back to Endress + Hauser Flow measurement
Endress+Hauser logo

Datasheet summary

Prosonic Flow Clamp On 93TA1

PDF datasheet mirror for Prosonic Flow Clamp On 93TA1 (Endress + Hauser Flow measurement). Verify with OEM before design.

Summary

Product Identification

  • Product Name: Prosonic Flow Clamp On 93TA1
  • Product Type: Portable ultrasonic flowmeter
  • Measuring Principle: Ultrasonic flow
  • Application: Measurement of liquid applications from outside the pipe with "Clamp On" sensors. Designed for temporary monitoring and test measurements, operated independently of mains power using a battery.

Operating Limits

  • Max. measurement error: +/-2.0 %
  • Measuring range: 0....452'389 m³/h
  • Max. process pressure: No limit

Medium Temperature Range

  • DN 15...65: -40...+150°C (-40...+302°F)
  • DN 50...300: -40...+170°C (-40...+338°F)
  • DN 100...4000: -40...+80°C (-40...+176°F)

Mechanical / Hydraulic

  • Nominal diameter range:
    • DN 15...65 (1/2"...2 1/2")
    • DN 50...300 (2"...12")
    • DN 100...4000 (4"...160")
  • Degree of protection: IP 40

Electrical

  • Outputs:
    • Integrated data logger/site manager
    • Easy data transfer via USB stick without additional software
    • Current output
  • Inputs:
    • 4...20mA
    • Digital communication FXA 193
  • Display/Operation: Four line backlit touch control
  • Power: Rechargeable battery

Features

  • Automatic frequency scan for maximum measuring performance
  • Quick and secure installation – specially designed mounting kits
  • No additional leakage paths – external measurement from outside the pipe
  • Process transparency – diagnostic capability
  • Integrated data logger and current input
  • Automatic recovery of data