Back to Endress + Hauser Flow measurement
Endress+Hauser logo

Datasheet summary

Prosonic Flow Inline 92F

PDF datasheet mirror for Prosonic Flow Inline 92F (Endress + Hauser Flow measurement). Verify with OEM before design.

Summary

Product identification

  • Product: Prosonic Flow Inline 92F
  • Type: Ultrasonic flowmeter
  • Measuring principle: Ultrasonic flow
  • Product headline: Highly accurate, loop-powered flowmeter with innovative parallel path design for minimum inlet runs.
  • Field of application: Inline device for homogeneous conductive and non-conductive liquids in the chemical and petrochemical industry.

Operating limits

  • Max. process pressure: PN 40 / ASME Cl. 300 / JIS 20K
  • Medium temperature range: -40 to +150 °C (-40 to +302 °F)
  • Medium temperature range (optional): -40 to +200 °C (-40 to +392 °F)
  • Ambient temperature range (compact): -40 to +60 °C (-40 to +140 °F)
  • Ambient temperature range (remote sensor): -40 to +80 °C (-40 to +176 °F)
  • Ambient temperature range (remote transmitter): -40 to +60 °C (-40 to +140 °F)
  • Max. measurement error (standard): ±0.5 % o.r. for 0.5 to 10 m/s (1.6 to 33 ft/s)
  • Max. measurement error (optional): ±0.3 % o.r. for 0.5 to 10 m/s (1.6 to 33 ft/s)
  • Measuring range: 0.5 to 10 m/s (1.6 to 33 ft/s)

Feed water

  • Liquids: Suitable for homogeneous conductive and non-conductive liquids.

Product water

  • Measured variables: Volume flow, calculated mass flow, sound velocity, flow velocity, signal strength.

Electrical

  • Power supply: 2 wire loop powered
  • Outputs:
    • 1x 4-20 mA HART
    • 1x Pulse/frequency/switch output (passive)
  • Digital communication: HART
  • Transmitter housing material: AlSi10Mg, coated
  • Degree of protection: IP67, type 4X enclosure
  • Degree of protection (remote option): IP68 type 6P enclosure

Mechanical / hydraulic

  • Nominal diameter range (2 path version): DN80 to 300 (3 to 12")
  • Nominal diameter range (3 path version): DN25 to 50 (1 to 2")
  • Nominal diameter range (4 path version): DN80 to 300 (3 to 12")
  • Wetted materials (Sensor):
    • A351-CF3M (DN25 to 100)
    • 1.4404/TP316/TP316L or A106 GrB (DN150 to 300)
  • Wetted materials (Transducer): 1.4404/316/316L
  • Wetted materials (Flanges): 1.4404/316/316L or A105/1.0432
  • Hazardous area approvals: ATEX, FM, CSA, JPNm, UK Ex
  • Other approvals and certificates: 3.1 material (wetted parts), calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), CRN, AD2000 PED, EAC marking.
  • Metrological approvals and certificates: Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025).
  • Pressure approvals and certificates: CRN, PED, AD2000.
  • Material certificates: 3.1 material (wetted parts).

Display / Operation

  • 2-line backlit display with 3 push buttons.

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.