Datasheet summary
Liquiphant FTL62
Engineering summary from PDF text extraction for Liquiphant FTL62. Verify every value with the OEM datasheet.
Summary
Product identification
- Product Name: Liquiphant FTL62
- Product Type: Point level switch with highly corrosion-resistant coating for liquids.
Application
- Point level switch for all liquids, for minimum or maximum detection in tanks, vessels, and piping, even in hazardous areas.
- Suitable for aggressive media due to various corrosion-resistant coatings, plastics, or enamel.
- Functions reliably regardless of flow, turbulence, air bubbles, foam, vibration, solids content, or buildup.
- Approved for safety systems with functional safety requirements up to SIL2/SIL3 in accordance with IEC 61508.
- No calibration needed.
Operating limits
- Process Temperature Range: –50 to +150 °C (–58 to +302 °F)
- Process Pressure Range: Up to 40 bar (580 psi)
- Viscosity: Up to 10,000 mPa⋅s
Feed water
- Measured Variable: Level (point level), MAX or MIN safety.
- Sensor Length:
- With plastic coating: maximum 3 m (9.8 ft)
- With enamel coating: maximum 1.2 m (3.9 ft)
Output and Input Variants
The Liquiphant FTL62 is available with several electronic inserts:
- 2-wire AC (FEL61): Switches load directly into the power supply circuit.
- Supply Voltage: 19 to 253 VAC, 50 Hz/60 Hz
- 3-wire DC-PNP (FEL62): Switches load via transistor (PNP), suitable for PLCs.
- Supply Voltage: 10 to 55 VDC
- Low-temperature option: –60 °C (–76 °F)
- Universal current connection, relay output (FEL64): Switches loads via 2 potential-free change-over contacts.
- Supply Voltage: 19 to 253 VAC / 19 to 55 VDC
- Low-temperature option: –60 °C (–76 °F)
- DC connection, relay output (FEL64DC): Switches loads via 2 potential-free change-over contacts.
- Supply Voltage: 9 to 20 VDC
- Low-temperature option: –60 °C (–76 °F)
- PFM output (FEL67): For connection to Nivotester switching units.
- Supply Voltage: 9.5 to 12.5 VDC
- Low-temperature option: –50 °C (–58 °F)
- 2-wire NAMUR > 2.2 mA/ < 1.0 mA (FEL68): For connection to isolating amplifiers according to NAMUR.
- Supply Voltage: 8.2 VDC ±20%
- Low-temperature option: –50 °C (–58 °F)
Output signal
- Switching Delay Times: Configurable (0.5s/1.0s, 0.25s/0.25s, 1.5s/1.5s, 5.0s/5.0s) for covering/uncovering.
- COM Interface: For connecting optional modules VU120 or VU121.
- Bluetooth® wireless technology (optional): For reading device and diagnostic data via the "SmartBlue" app.
Performance characteristics
- Reference Operating Conditions: Defined ambient and process temperature, density, viscosity, pressure, and installation.
- Maximum Measured Error:
- Plastic coating: –0.2 to –1.2 mm
- Enamel coating: 0 to 0.9 mm
- Hysteresis:
- Plastic coating: 2.5 mm
- Enamel coating: 3.5 mm
- Non-repeatability: 0.5 mm
- Influence of Process Temperature: Switch point shift varies with temperature and coating type (ECTFE, PFA, Enamel).
- Influence of Process Pressure: Switch point shift varies with pressure and coating type (ECTFE, PFA, Enamel).
- Influence of Process Medium Density: Switch point deviation is specified for different density settings and coating types.
Mounting
- Mounting Location/Orientation: Any orientation for pipes up to 500 mm; vertical from above for long pipes. Minimum distance of 10 mm from tank/pipe wall to tuning fork.
- Viscosity Considerations:
- Low viscosity (< 2,000 mPa⋅s): Tuning fork can be positioned within installation socket.
- High viscosity (≤ 10,000 mPa⋅s): Tuning fork must be located outside the installation socket.
- Installation in Piping: Flow velocity up to 5 m/s possible under certain conditions.
- Cable Entry Alignment: Housing can be rotated.
- Special Instructions: Vessel insulation may be required for high process temperatures; support may be needed for pipes/sensors longer than 1,600 mm or under severe dynamic load.
Environment
- Ambient Temperature Range: –40 to +70 °C (–40 to +158 °F).
- Optional: –50 °C (–58 °F) or –60 °C (–76 °F) with restricted operating life/performance.
- Plastic housing minimum: –20 °C (–4 °F).
- Storage Temperature: Not explicitly stated in extract.
- Humidity: Not explicitly stated in extract.
- Operating Altitude: Not explicitly stated in extract.
- Climate Class: Not explicitly stated in extract.
- Degree of Protection: Not explicitly stated in extract.
- Vibration Resistance: Not explicitly stated in extract.
- Shock Resistance: Not explicitly stated in extract.
- Mechanical Load: Not explicitly stated in extract.
- Pollution Degree: Not explicitly stated in extract.
- Electromagnetic Compatibility (EMC): Not explicitly stated in extract.
Mechanical Construction
- Dimensions: Refer to specific product diagrams in the datasheet.
- Coating Material and Layer Thickness: Specific details are available in the datasheet.
- Weight: Not explicitly stated in extract.
- Materials: Various materials are used; specific details are available in the datasheet.
User Interface
- Operation Concept: Onsite and remote operation supported.
- Onsite Operation: Local display may be available.
- Remote Operation: Possible via interfaces.
Certificates and Approvals
- CE mark
- RCM marking
- Ex approval (details in separate Ex documentation)
- Overfill protection
- Functional safety (SIL2/SIL3)
- Marine approvals
- Radio approval
- CRN approval
- Test, certificate, declaration
- Pressure Equipment Directive
- Process seal as per ANSI/ISA 12.27.01
- China RoHS symbol
- RoHS
- EAC conformity
- ASME B 31.3/31.1
Accessories
- Test magnet
- Protective covers
- M12 socket
- Bluetooth module VU121 (optional)
- LED module VU120 (optional)
Documentation
- Standard documentation
- Supplementary device-dependent documentation