Datasheet summary
Liquiphant FTL63
Engineering summary from PDF text extraction for Liquiphant FTL63. Verify every value with the OEM datasheet.
Summary
Product identification
- Product: Liquiphant FTL63
- Type: Vibronic point level switch
Application
- Point level detection for all pumpable liquids, for minimum or maximum detection.
- Suitable for process tanks, storage tanks, and piping.
- Available in versions suitable for hazardous areas.
- Functions include leakage monitoring, pump dry-running protection, and overfill prevention.
- Not affected by flow, turbulence, air bubbles, foam, vibration, solids content, or buildup.
Operating limits
- Process temperature range: –50 to +150 °C (–58 to +302 °F)
- Process pressure range: up to 64 bar (928 psi)
- Viscosity: up to 10,000 mPa⋅s
Performance characteristics
- Maximum measured error: ± 1 mm at switch point (under reference operating conditions)
- Hysteresis: Typically 2.5 mm
- Non-repeatability: 0.5 mm
- Switch point movement due to process temperature: +1.4 to –2.6 mm over –50 to +150 °C range
- Switch point movement due to process pressure: 0 to 2.6 mm over –1 to +64 bar range
Electronic Inserts
The FTL63 is available with various electronic inserts, each with different electrical characteristics and supply voltage requirements:
- 2-wire AC (FEL61):
- Supply voltage: 19 to 253 VAC, 50 Hz/60 Hz
- Power consumption: ≤ 2 VA
- Current consumption (residual when blocked): ≤ 3.8 mA
- Connectable load: Minimum 0.5 VA at 24 V (20 mA) to Maximum 89 VA at 253 V (350 mA)
- 3-wire DC-PNP (FEL62):
- Supply voltage: 10 to 55 VDC (CLASS 2 or SELV required)
- Power consumption: ≤ 0.5 W
- Current consumption (without load): ≤ 10 mA
- Load current: ≤ 350 mA (with overload and short-circuit protection)
- Universal current connection, relay output (FEL64):
- Supply voltage: 19 to 253 VAC, 50 Hz/60 Hz or 19 to 55 VDC
- Power consumption: < 25 VA, < 1.3 W
- Connectable load (relay contacts): ≤ 6 A at 253 VAC (1500 VA, cos φ = 1); ≤ 6 A at 30 VDC
- DC connection, relay output (FEL64DC):
- Supply voltage: 9 to 20 VDC (CLASS 2 or SELV required)
- Power consumption: < 1.0 W
- Connectable load (relay contacts): ≤ 6 A at 253 VAC (1500 VA, cos φ = 1); ≤ 6 A at 30 VDC
- PFM output (FEL67):
- Supply voltage: 9.5 to 12.5 VDC (CLASS 2 or SELV required)
- Power consumption: ≤ 150 mW
- 2-wire NAMUR > 2.2 mA/< 1.0 mA (FEL68):
- Supply voltage: 8.2 VDC ±20% (CLASS 2 or SELV required)
- Power consumption: < 6 mW to < 38 mW
Output signal characteristics
- Switch output delay: Factory setting is 0.5 s when covered and 1.0 s when uncovered. Other options available (0.25 s, 1.5 s, 5.0 s).
- COM interface: For connecting optional modules VU120 or VU121.
- Bluetooth® wireless technology (optional): Allows data readout via the "SmartBlue" app. Device settings cannot be changed via Bluetooth.
Mechanical construction
- Maximum sensor length: 3 m (10 ft)
Environment
- Ambient temperature range: –40 to +70 °C (–40 to +158 °F). Optional extended ranges down to –60 °C (–76 °F) with restricted operating life and performance.
- Storage temperature: Not specified in extract.
- Humidity: 5 to 80% rF ±5% (under reference operating conditions).
- Degree of protection: Not specified in extract.
- Vibration resistance: Not specified in extract.
- Shock resistance: Not specified in extract.
Certificates and approvals
- Includes CE mark, RCM marking, and Ex approvals.
- Material compliance for contact with food (EC1935/2004, FDA, GB 4806, cGMP).
- Hygienic design certifications (3-A, EHEDG, ASME BPE).
Optional accessories
- LED module VU120
- Bluetooth module VU121
Disclaimer This summary is extracted from a datasheet and may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)