Back to Endress + Hauser Level measurement
Endress+Hauser logo

Datasheet summary

Liquipoint FTW23

Engineering summary from PDF text extraction for Liquipoint FTW23. Verify every value with the OEM datasheet.

Summary

Product identification

  • Product Name: Liquipoint FTW23
  • Product Type: Capacitance point level measurement

Application

The Liquipoint FTW23 is a point level switch designed for water-based liquids, with suitability for alcohol-, oil-based liquids, or powdered products when using IO-Link. It is commonly used in storage tanks, mixing vessels, and pipes. The device meets international hygiene requirements for the food and beverage industry.

Operating limits

  • Process Temperature: Up to 100 °C (212 °F) continuously.
  • Cleaning/Sterilization Temperature: Up to 135 °C (275 °F) for 60 minutes.
  • Process Pressure: –1 to +16 bar (–14.5 to +232 psi).

Feed water

  • Default Medium: Water-based media with a dielectric constant (DC) > 20.
  • With IO-Link: Adjustable for media with DC > 1.5, including water-, alcohol-, and oil-based liquids, or powdered products.

Product water

Not applicable for this product.

Electrical

  • Supply Voltage: 10 to 30 V DC (minimum 18 V DC required for IO-Link).
  • Power Consumption: < 1.2 W (at max. load: 200 mA).
  • Current Consumption: < 40 mA.
  • Switch Output:
    • 3-wire DC-PNP: 2 DC-PNP outputs, XOR switched, 200 mA connectable load (short-circuit proof).
    • Devices with IO-Link: 3- or 4-wire DC-PNP, 2 freely configurable DC-PNP outputs.
      • 1 switch output active: 200 mA connectable load.
      • Both switch outputs active: 105 mA each connectable load.
  • Residual Voltage: < 3 V.
  • Residual Current: < 100 µA.
  • Overvoltage Protection: Category II.
  • Reverse Polarity Protection: Integrated.
  • Short-Circuit Protection: Integrated, with intelligent monitoring and automatic resumption of normal operation.

Mechanical / hydraulic

  • Housing: Robust stainless steel.
  • Connection Options: M12 connector (optional with IP69 protection).
  • Wetted Material: 316L (1.4404), PEEK.
  • Wetted Sensor Surface Roughness: Ra ≤ 0.76 µm (30 µin).
  • Weight: Max. 300 g (10.58 oz).
  • Degree of Protection:
    • IP65/67 (NEMA Type 4X Enclosure for plastic housing cover).
    • IP66/68/69 (NEMA Type 4X/6P Enclosure for metal housing cover).
  • Shock Resistance: In accordance with prEN 60068-2-27: a = 300 m/s², 30 g.
  • Vibration Resistance: In accordance with EN 60068-2-64: a(RMS) = 50 m/s², f = 5 to 2000 Hz.
  • Cleaning: Resistant to typical cleaning agents; passed Ecolab test.

Performance characteristics

  • Switching Accuracy: ±2 mm (0.08 in).
  • Hysteresis: Typically ±1 mm (0.04 in).
  • Non-repeatability: ±1 mm (0.04 in).
  • Switch-on Delay: < 2 s.
  • Switching Delay:
    • 0.5 s (sensor covered).
    • 1.0 s (sensor uncovered).
    • 0.3 to 600 s (IO-Link communication).

Environment

  • Ambient Temperature Range: –20 to +70 °C (–4 to +158 °F).
  • Storage Temperature: –40 to +85 °C (–40 to +185 °F).
  • Climate Class: DIN EN 60068-2-38/IEC 68-2-38: test Z/AD.
  • Altitude: Up to 2000 m (6600 ft) above sea level.

Certificates and approvals

  • CE approval
  • EAC conformity
  • RCM marking
  • CSA C/US General Purpose
  • 3-A and EHEDG certificates
  • Meets requirements of EU 1935/2004, 10/2011, 2023/2006 and FDA 21 CFR 177.2415.

IO-Link

  • Interface: IO-Link communication interface type 2 with second IO function on pin 4.
  • Specification: Version 1.1, Smart Sensor Profile 2nd Edition.
  • Speed: COM2; 38.4 kBaud.
  • Minimum Cycle Time: 6 msec.
  • Process Data Width: 16 bit.

Operability

  • Onsite function check via LED indication.
  • Function testing of switch outputs with a test magnet.
  • IO-Link offers operator-oriented menu structure, quick commissioning, and diagnostic behavior.

Accessories

  • Process adapters (e.g., M24).
  • Weld-in adapters.
  • Slotted nut DIN11851.
  • Test magnet.
  • Special socket wrench.
  • Cables with M12 connectors (IP69 with/without LED, IP67 without LED).