Summary

Product Identification

  • Product: Micropilot FMR10
  • Type: Free space radar level sensor
  • Document: TI01266F/00/EN/09.22-00, dated 2022-12-13

Application

  • Level measurement for liquids in storage tanks, open basins, pump shafts, and canal systems.
  • Features Bluetooth® wireless technology for remote access via iOS/Android app "SmartBlue".
  • Full PVDF body for long sensor lifetime.
  • Hermetically sealed electronics to prevent water ingress.

Operating Limits

  • Measuring range: up to 12 m (39.37 ft) (with 40 mm antenna and flooding protection tube accessory)
  • Process temperature: –40 to +60 °C (–40 to +140 °F)
  • Process pressure: –1 to 3 bar gauge (–14 to 43.5 psi gauge); absolute pressure < 4 bar (58 psi)
  • Ambient temperature range (device): –40 to +60 °C (–40 to +140 °F)
  • Storage temperature: –40 to +80 °C (–40 to +176 °F)
  • Operating altitude: Generally up to 2,000 m (6,600 ft) above sea level.

Feed Water / Process Medium

  • Dielectric constant (εr): ≥ 4 for liquids. Contact Endress+Hauser for lower εr values.

Product Water / Measured Variable

  • Measured variable: Distance from reference point to product surface. Level is calculated based on the entered empty distance.
  • Accuracy (typical, under reference conditions):
    • Digital (SmartBlue): ± 5 mm (±0.2 in) sum of non-linearity, non-repeatability, and hysteresis; ± 4 mm (±0.16 in) offset/zero point.
    • Analog (4-20mA): ±0.02 % span (linearity, repeatability, hysteresis); ±0.03 % span offset/zero point.
  • Measured value resolution (dead band): 1 mm (digital), 4 µA (analog).
  • Response time: < 3 s (tank height < 5 m, damping off).

Electrical

  • Supply voltage: 10.5 to 30 VDC
  • Power consumption: Max. 675 mW
  • Current consumption: Max. < 25 mA; Max. start-up current 3.6 mA.
  • Output signal: 4 to 20 mA (analog)
  • Digital output: Bluetooth® wireless technology (for SmartBlue app)
  • Alarm signal: 22.5 mA (current output, in accordance with NAMUR NE 43)
  • Integrated overvoltage protection.

Mechanical / Hydraulic

  • Ingress protection: IP66/68 / NEMA 4X/6P
  • Antenna size: 40 mm (1.5 in)
  • Process connection: G 1 1/2", NPT 1 1/2" (also other sizes available via accessories like flanges)
  • Body material: Full PVDF construction.
  • Weight: Approx. 3.0 kg (6.6 lb) (including 10 m cable).
  • Standard cable length: 10 m (33 ft); extendable up to 300 m (984 ft) total length.

Environment

  • Degree of protection: IP66, NEMA 4X; IP68, NEMA 6P (24 h at 1.83 m water depth).
  • Vibration resistance: DIN EN 60068-2-64/IEC 60068-2-64: 20 to 2,000 Hz, 1 (m/s²)²/Hz.
  • Electromagnetic compatibility (EMC): In accordance with EN 61000 series and NAMUR Recommendation EMC (NE 21).

Certificates and Approvals

  • CE mark
  • RoHS (2011/65/EU and (EU) 2015/863)
  • EAC conformity
  • RCM marking
  • CSA C/US General Purpose (Non-hazardous area)
  • EN 302729-1/2 radio standard compliant.
  • FCC / Industry Canada compliant.
  • Japanese Radio Law and Japanese Telecommunications Business Law Compliance.