Datasheet summary
Micropilot M FMR60
Engineering summary from PDF text extraction for Micropilot M FMR60. Verify every value with the OEM datasheet.
Summary
Product identification
The Micropilot FMR60 is a free space radar level measurement instrument.
Application
- Continuous, non-contact level measurement of liquids, pastes, and sludges.
- Features a PTFE drip-off antenna.
Operating limits
- Maximum measuring range: 50 m (164 ft)
- Process temperature: –40 to +130 °C (–40 to +266 °F)
- Process pressure: –1 to +16 bar (–14.5 to +232 psi)
- Ambient temperature range (Measuring device): –40 to +80 °C (–40 to +176 °F)
- Ambient temperature range (Local display): –20 to +70 °C (–4 to +158 °F)
- Storage temperature: –40 to +80 °C (–40 to +176 °F)
Performance characteristics
- Accuracy:
- Measuring distance up to 0.8 m (2.62 ft): ± 4 mm (±0.16 in) or ±0.03 % (analog)
- Measuring distance > 0.8 m (2.62 ft): ± 1 mm (±0.04 in) or ±0.02 % (analog)
- Non-repeatability: ≤ 1 mm (0.04 in)
- Measured value resolution (Analog): 1 µA
- Response time: < 3.6 s (with damping switched off, measuring rate ≥ 1.3 s⁻¹ at U ≥ 24 V)
- Influence of ambient temperature:
- Digital (HART): average TC = 2 mm/10 K
- Analog (current output): Zero point (4 mA) TC = 0.02 %/10 K, Span (20 mA) TC = 0.05 %/10 K
Feed water
- Dielectric constant (εr): ≥ 1.9 for liquids.
- Minimum level for low dielectric constants (εr ≤ 4): 80 mm (3.15 in) above the bottom of the tank.
Product water
- Not specified in the provided text.
Electrical
- Output signal: HART (FSK ±0.5 mA over current signal, 1200 Bit/s, Galvanic isolation: Yes)
- Switch output (optional for HART devices): Open collector, switches when programmable switch-on/off point is reached.
- Electrical connection data: U = 16 to 35 VDC, I = 0 to 40 mA
- Supply voltage:
- 2-wire, 4-20 mA HART, passive: 14 to 35 V (minimum supply voltage increases by 2 V if Bluetooth module is used).
- 2-wire, 4-20 mA HART, switch output: 16 to 35 V (minimum supply voltage increases by 2 V if Bluetooth module is used).
- 2-wire, 4-20 mA HART, 4-20 mA: 16 to 30 V (minimum supply voltage increases by 2 V if Bluetooth module is used).
- Power consumption:
- 2-wire; 4-20mA HART: < 0.9 W
- 2-wire; 4-20mA HART, switch output: < 0.9 W
- 2-wire; 4-20mA HART, 4-20mA: < 2 x 0.7 W
- Current consumption: 3.6 to 22 mA (Nominal current).
- Signal on alarm (Current output): Adjustable: 3.59 to 22.5 mA (Minimum alarm: 3.6 mA, Maximum alarm: 22 mA).
Mechanical / hydraulic
- Antenna: Drip-off, PTFE, 50 mm / 2"
- Dimensions:
- GT19 housing (plastic PBT): ø106 mm (4.17 in) diameter
- GT20 housing (aluminum coated): ø112 mm (4.41 in) diameter
- Weight: Not specified in the provided text.
- Materials: Various options for housing, antenna, process connection, and weather protection cover are described.
- Process connection: Threaded (G1-1/2", MNPT1-1/2") or Flange (3"/DN80, 4"/DN100, 6"/DN150).
- Degree of protection:
- Housing closed: IP68, NEMA6P (24 h at 1.83 m under water); IP66, NEMA4X
- Housing open: IP20, NEMA1
- Display module: IP22, NEMA2
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.