Datasheet summary
Micropilot M FMR60B
Engineering summary from PDF text extraction for Micropilot M FMR60B. Verify every value with the OEM datasheet.
Summary
Product Identification
- Product Name: Micropilot FMR60B
- Protocol: PROFIBUS PA
- Measuring Technology: Free-space radar
- Document Revision: TI01693F/00/EN/02.24-00
- Document Date: 2024-12-04
Application
- Continuous, non-contact level measurement of liquids, pastes, and sludges.
- Process connections: Thread or mounting bracket.
Operating Limits
- Maximum measuring range: 50 m (164 ft)
- Temperature range (process): –40 to +200 °C (–40 to +392 °F)
- Pressure range (process): –1 to +20 bar (–14.5 to +290 psi)
- Accuracy: ±1 mm (±0.04 in)
Input
- Measured variable: Distance between reference point and product surface.
- Operating frequency: Approx. 80 GHz.
- Transmission power:
- Peak power: <1.5 mW
- Average output power: <70 µW
Output
- Protocol: PROFIBUS PA (according to EN 50170 Volume 2, IEC 61158-2)
- Signal coding: Manchester Bus Powered (MBP) type 1
- Data transmission rate: 31.25 kBit/s, voltage mode
- Galvanic isolation: Yes
- Signal on alarm: Diagnostics in accordance with PROFIBUS PA Profile 3.02. Status signal (in accordance with NAMUR Recommendation NE 107) with plain text display.
- Linearization: Converts measured value into any unit of length, weight, flow, or volume. Pre-programmed curves for various vessel types and manual entry of up to 32 value pairs.
- Protocol-specific data:
- Manufacturer ID: 17 (0x11)
- Ident number: 0x1568 or 0x9700
- Profile version: 3.02
- Output values (Analog Input): Level linearized, Distance, Volume, Terminal voltage, Electronic temperature, Sensor temperature, Absolute echo amplitude, Relative echo amplitude, Area of incoupling, Build-up index (optional), Foam index (optional).
- Output values (Digital Input, with specific application package): Build-up detected (optional), Foam detected (optional).
Power Supply
- Supply voltage:
- Non-hazardous, Ex d, Ex e: 9 to 32 VDC
- Ex i: 9 to 30 VDC
- Nominal current: 14 mA
- Error current FDE: 0 mA
- Use suitable and certified Profibus PA components for power supply.
- FISCO/FNICO-compliant in accordance with IEC 6079-27.
- Supply is not polarity dependent.
Mechanical / Hydraulic
- Process connections: Thread or mounting bracket.
- Antenna types and maximum measuring ranges:
- Encapsulated, PVDF, 40 mm (1.5 in): 40 m (131 ft)
- Drip-off, PTFE, 50 mm (2 in): 50 m (164 ft)
- Integrated, PEEK, 20 mm (0.75 in): 10 m (32.8 ft)
- Integrated, PEEK, 40 mm (1.5 in): 22 m (72 ft)
- Materials: See official PDF for detailed material specifications.
Environment
- Ambient temperature range:
- Without LCD display: –40 to +85 °C (–40 to +185 °F)
- With LCD display: –40 to +85 °C (–40 to +185 °F) with limitations at extreme temperatures. Usable without limitations from –20 to +60 °C (–4 to +140 °F).
- Process temperature limits: Vary significantly based on housing material and specific approval (e.g., CSA C/US). Consult the official PDF for detailed charts and conditions.
- Degree of protection: See official PDF.
- Vibration resistance: See official PDF.
- Electromagnetic compatibility (EMC): Satisfies IEC/DIN EN 61326-1 (Industrial environment).
Performance Characteristics
- Reference operating conditions:
- Temperature: +24 °C (±5 °C)
- Pressure: 960 mbar abs. (±100 mbar)
- Humidity: 60 % (±15 %)
- Maximum measured error:
- Measuring distance up to 0.8 m (2.62 ft): max. ±4 mm (±0.16 in)
- Measuring distance > 0.8 m (2.62 ft): ±1 mm (±0.04 in)
- Non-repeatability: ≤ 1 mm (0.04 in)
- Measured value resolution: Digital: 1 mm
- Response time: < 1 s (with damping switched off). Configurable.
- Influence of ambient temperature: Average TC = 2 mm/10 K.
- Influence of gas phase: High pressure can cause systematic measured error, dependent on gas type and temperature. See official PDF for detailed error percentages for various gases.
Installation
- Mounting location: Avoid installation above filling curtain; maintain recommended distance from tank wall.
- Orientation: Vertical alignment of antenna axis perpendicular to the product surface is recommended.
- Installation instructions: Specific maximum nozzle lengths (Hmax) provided for different antenna types and nozzle diameters.
- Beam angle: Varies by antenna type (e.g., Encapsulated PVDF 40 mm: 8°, PTFE 50 mm: 6°, PEEK 20 mm: 14°). Beamwidth diameter (W) calculation provided.
- Special mounting instructions: Measurement through open ball valves, external measurement through plastic covers or dielectric windows (requires specific dielectric constant and thickness considerations).
Certificates and Approvals
- CE mark
- RoHS
- RCM marking
- Ex approvals (refer to official PDF for details)
- Radio approval (EN 302729, EN 302372, FCC, Industry Canada)
Disclaimer