Back to Endress + Hauser Level measurement
Endress+Hauser logo

Datasheet summary

Micropilot M FMR66B

Engineering summary from PDF text extraction for Micropilot M FMR66B. Verify every value with the OEM datasheet.

Summary

Product identification

  • Product: Micropilot FMR66B HART
  • Type: Free-space radar level sensor for bulk solids.
  • Document: TI01686F/00/EN/05.24-00

Application

  • Continuous, non-contact level measurement of powdered to granular bulk solids.
  • Process connections: thread or mounting bracket.

Operating limits

  • Maximum measuring range: 50 m (164 ft)
  • Process temperature range: –40 to +130 °C (–40 to +266 °F)
  • Process pressure range: –1 to +16 bar (–14.5 to +232 psi)
  • Accuracy: ±3 mm (±0.12 in)

Feed water

  • Dielectric constant: εr ≥ 10 for external measurement through plastic cover or dielectric windows.

Product water

  • Not applicable for this product type.

Electrical

  • Output signal: HART, 4 to 20 mA passive (2-wire).
  • Optional outputs: 4 to 20 mA passive (current output 2), Switching output (open collector).
  • Supply voltage:
    • Non-hazardous, Ex d, Ex e: 10.5 to 35 VDC
    • Ex i: 10.5 to 30 VDC
  • Nominal current: 4 to 20 mA
  • Power consumption: 0.9 W max.
  • HART load: Min. 250 Ω
  • Wireless HART:
    • Minimum start-up voltage: 10.5 V
    • Start-up current: < 3.6 mA
    • Starting time: < 15 s
    • Minimum operating voltage: 10.5 V
    • Multidrop current: 4 mA
    • Time to establish connection: < 30 s

Mechanical / hydraulic

  • Antenna options:
    • Encapsulated, PVDF, 40 mm (1.5 in) - Max measuring range: 30 m (98 ft)
    • Drip-off, PTFE, 50 mm (2 in) - Max measuring range: 50 m (164 ft)
  • Materials: Options include PVDF, PTFE, 316L, coated aluminum, plastic.
  • Dimensions: See official PDF for detailed dimensional drawings.
  • Weight: See official PDF for specific weight information.
  • Degree of protection:
    • Housing: IP66/68, NEMA Type 4X/6P
    • M12 plug: IP66/67 (housing closed, cable plugged in), IP20 (housing open or cable not plugged in)
    • HAN7D plug: IP65, NEMA Type 4X

Environment

  • Ambient temperature range:
    • Without LCD: Standard –40 to +85 °C (–40 to +185 °F); Optionally –50 to +85 °C or –60 to +85 °C with restricted performance.
    • With LCD: –40 to +85 °C (–40 to +185 °F) with limitations in optical properties; usable without limitations up to –20 to +60 °C.
  • Storage temperature:
    • Without LCD: –40 to +90 °C (–40 to +194 °F)
    • With LCD: –40 to +85 °C (–40 to +185 °F)
  • Climate class: DIN EN 60068-2-38 (test Z/AD)
  • Installation height: Generally up to 2,000 m (6,600 ft) above sea level.

Performance characteristics

  • Reference operating conditions: Temperature +24 °C (±5 °C), Pressure 960 mbar abs. (±100 mbar), Humidity 60% (±15%).
  • Measured value resolution:
    • Digital: 1 mm
    • Analog: 1 µA
  • Maximum measured error:
    • Up to 1.5 m: max. ±20 mm (±0.79 in)
    • 1.5 m: ±3 mm (±0.12 in)

  • Non-repeatability: ≤ 1 mm (0.04 in) (included in accuracy)
  • Response time: < 1 s (when damping is switched off, pulse frequency ≥ 5/s)
  • Influence of ambient temperature: Specific coefficients (TC) provided for digital and analog outputs.

Certifications and approvals

  • CE mark
  • RoHS
  • RCM marking
  • Ex approvals (specific details not listed here, refer to PDF)
  • SIL2 as per IEC 61508, SIL3 for homogeneous redundancy
  • Radio approval (EN 302729, EN 302372, FCC, Industry Canada)

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.