Back to Endress + Hauser Level measurement
Endress+Hauser logo

Datasheet summary

Micropilot M FMR67B

Engineering summary from PDF text extraction for Micropilot M FMR67B. Verify every value with the OEM datasheet.

Summary

Product Identification

  • Product Name: Micropilot FMR67B
  • Communication Protocol: PROFIBUS PA
  • Measurement Type: Free-space radar for non-contact level measurement
  • Application: Continuous level measurement of powdered to granular bulk solids.

Operating Limits

  • Maximum Measuring Range: 125 m (410 ft)
  • Process Temperature Range: –40 to +450 °C (–40 to +842 °F) - Note: Ambient temperature limits vary based on housing material and process temperature. See Environment section for details.
  • Process Pressure Range: –1 to +160 bar (–14.5 to +2 321 psi)
  • Operating Frequency: Approx. 80 GHz

Input

  • Measured Variable: Distance between reference point and product surface. Level is calculated based on the entered empty distance.

Performance Characteristics

  • Accuracy:
    • Up to 1.5 m measuring distance: max. ±20 mm (±0.79 in)
    • Greater than 1.5 m measuring distance: ±3 mm (±0.12 in)
  • Non-repeatability: ≤ 1 mm (0.04 in)
  • Measured Value Resolution (Digital): 1 mm
  • Response Time: Less than 1 s (with damping switched off, pulse frequency ≥ 5/s)
  • Influence of Ambient Temperature: Average TC = 3 mm/10 K

Electrical

  • Supply Voltage:
    • Non-hazardous, Ex d, Ex e: 9 to 32 VDC
    • Ex i: 9 to 30 VDC
  • Nominal Current: 14 mA
  • Error Current (FDE): 0 mA
  • Communication: PROFIBUS PA (Manchester Bus Powered (MBP) type 1, 31.25 kBit/s, voltage mode)
  • Galvanic Isolation: Yes

Mechanical / Hydraulic

  • Antenna Types:
    • PTFE lens antenna
    • Ceramic sealed high-temperature horn antenna
  • Process Connections: Flanges with purge air and alignment unit
  • Materials: See the official PDF for exact tabulated values.
  • Dimensions: See the official PDF for exact tabulated values.
  • Weight: See the official PDF for exact tabulated values.
  • Degree of Protection: IP66/68, NEMA TYPE 4X/6P (Housing)
  • Cable Entries: Various options including M20, G ½, NPT ½ threads, and M12 plug. Degree of protection varies based on installation.

Environment

  • Ambient Temperature Range (Standard, without LCD): –40 to +85 °C (–40 to +185 °F)
  • Storage Temperature:
    • Without LCD display: –40 to +90 °C (–40 to +194 °F)
    • With LCD display: –40 to +85 °C (–40 to +185 °F)
  • Climate Class: DIN EN 60068-2-38 (test Z/AD)
  • Installation Height: Generally up to 5000 m (16,404 ft) above sea level.

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.