Micropilot Wireless FWR30
Engineering summary from PDF text extraction for Micropilot Wireless FWR30. Verify every value with the OEM datasheet.
Summary
Product identification
- Product Name: Micropilot FWR30
- Type: Free-space radar level sensor
- Document Number: TI01499F/00/EN/10.25-00
- Serial Number Example: 71699833
Application
Battery-operated level sensor for monitoring remote and mobile applications.
Operating limits
- Maximum measuring range: 30 m (98 ft)
- Ambient temperature: –20 to +60 °C (–4 to +140 °F)
- Storage temperature: –20 to +60 °C (–4 to +140 °F)
- Operating altitude: Up to 2,000 m (6,600 ft) above sea level.
Feed water
- Measured Variable: Level, Ambient temperature, Position, GPS
- Level Accuracy: ±2 mm (0.08 in)
- Ambient Temperature Accuracy: ±2 °C (4 °F)
- Measurement of Media with Absorbing Gas Phase: Special consideration or contact with Endress+Hauser is required for media like Ammonia, Acetone, Methylene chloride, Methyl ethyl ketone, Propylene oxide, VCM.
Product water
- Degree of protection: IP66/IP68, NEMA Type 4X/6P
Operating frequency
- Frequency: 80 GHz (for measurement purposes only)
Input
- Measured variables include:
- Level: 0 to 30 m (0 to 98 ft) ±2 mm (0.08 in)
- Ambient temperature: –20 to +60 °C (–4 to +140 °F) with an accuracy of ± 2 °C (4 °F)
- Position: Angle of device to the horizontal (Range: 0 to 180°, measurable if sensor does not move)
- GPS: ±20 m (66 ft) in free field conditions
Output
- Output signal: Cellular radio LTE-M, NB-IoT, GPRS, EDGE
- Available options depending on order code (030 options A, B, C), supporting various frequency bands for different regions (EU, US, Global).
- Transmission interval: Configurable between 15 minutes and 24 hours. Battery life depends on this setting.
- Protocol: TCP/IP, TLS (v1.2), HTTPS
Power supply
- Type: Replaceable battery, standard size, lithium (D)
- Voltage: 3.6 V
- Capacity: 19 Ah (included in delivery)
- Designation: ER34615 (primary battery lithium thionyl chloride)
- Recommended batteries: Tadiran SL-2880 (Europe), Tadiran TL-4930 (outside Europe). Tadiran SL-2870 (Europe) or Tadiran TL-5930 (outside Europe) are also usable but may affect indicated battery lives.
- Battery Status Indication: Full, medium, low, or critical. LED flashes red every 10 seconds if charge is low or critical.
- Battery Life: Varies significantly based on transmission interval, measuring interval, and GPS usage. Can exceed 8-10 years under specific conditions, or approximately 140-500 days with shorter transmission intervals. GPS operation halves battery life.
- Safety Notice: Do not charge, open, expose to fire or heat above 100 °C (212 °F). Only use ER34615 battery. Dispose of used batteries properly.
Performance characteristics
- Reference operating conditions:
- Temperature: +24 °C (+75 °F) ±5 °C (±9 °F)
- Pressure: 960 mbar abs. (14 psia) ±100 mbar (±1.45 psi)
- Humidity: 60 % ±15 %
- Reflector: Metal plate ≥ 1 m (40 in) diameter.
- Measurement accuracy: ±2 mm (0.08 in) within the entire measuring range.
- Influence of ambient temperature: Temperature coefficient ≤ 4 mm (0.16 in) per 10 K.
Mechanical / hydraulic
- Dimensions: Refer to the Product Configurator on www.endress.com for exact dimensions. Rounded values for housing and accessories are provided.
- Housing Dimensions (approximate): 120 mm (4.72 in) x 120 mm (4.72 in)
- Weight (Housing with original battery): 0.5 kg (1.1 lb)
- Weight (Housing without battery): 0.4 kg (0.88 lb)
- Materials:
- Housing: Plastic PBT/PC, Seal: TPE
- Radar antenna: Plastic PBT/PC
- Accessories (Mounting brackets, Adapters): AISI316 L (1.4404)
- Process Connection Adapters:
- G 1½" (Max. process pressure: 4 bar abs. (58 psi))
- MNPT 1½" (Max. process pressure: 4 bar abs. (58 psi))
Installation
- Mounting: Can be mounted indoors or outdoors. Suitable for metal vessels, silos, vertical pipes, and non-conductive plastic IBC tanks.
- Mounting Instructions:
- Mount parallel to the tank ceiling to avoid interference.
- Radar antenna should not be covered by metal objects.
- Avoid mounting interference-causing objects (e.g., tank fittings, agitators) below or near the radar.
- When mounting outdoors on IBC tanks, ensure the device is not in a depression where water can collect.
- Nozzle Height and Distance to Wall: Tables provide guidance for maximum nozzle height (Hmax) and distance to wall based on tank diameter.
- Beam Angle: 8°
Environment
- Relative humidity: 0 to 95%
- Climate class: DIN EN 60068-2-38/IEC 68-2-38: test Z/AD
- Vibration and shock resistance: In accordance with DIN EN 60068-2-27 / IEC 60068-2-27 / DIN EN 60068-2-64: 18 ms, 30g, half-sine.
- Electromagnetic compatibility: In accordance with IEC/EN 61326-1.
Certificates and approvals
- CE mark: Meets applicable EU directives.
- RoHS: Complies with Directive 2011/65/EU (RoHS 2) and Delegated Directive (EU) 2015/863 (RoHS 3).
- EN 302729-1/2 radio standard: Approved for unrestricted use inside and outside of closed vessels in EU and EFTA countries that have implemented this standard. Specific restrictions apply for operation outside closed vessels, including distance from astronomy stations.
- FCC: Compliant with Part 15 of FCC rules. FCC IDs provided for relevant options. Specific installation requirements (downward operating position, distance from RAS stations) apply.
- Industry Canada: Compliant with licence-exempt RSS standard(s). IC IDs provided for relevant options. Specific installation requirements (distance from DRAO) apply.
- Japanese Radio Law and Telecommunication Business Law: Approved.
- Radiofrequency radiation exposure information: Compliant with FCC and IC limits. Minimum distance of 20 cm between radiator and body required.
Accessories
- Mounting bracket pipe/IBC
- Mounting bracket wall/ceiling
- G 1½" adapter
- MNPT 1½" adapter
Supplementary documentation
- Available via Device Viewer (www.endress.com/deviceviewer) or Endress+Hauser Operations app using the serial number.