Back to Endress + Hauser Level measurement
Endress+Hauser logo

Datasheet summary

Prosonic FMU40

Engineering summary from PDF text extraction for Prosonic FMU40. Verify every value with the OEM datasheet.

Summary

Product Identification

  • Product Name: Prosonic M FMU41
  • Technology: Ultrasonic measuring technology
  • Type: Compact transmitter for non-contact level and flow measurement
  • Communication: HART protocol

Application

  • Two-wire version for non-contact level and flow measurement.
  • Process connection: Thread.
  • Suitable for liquids and bulk solids.
  • Features international explosion protection certificates.

Operating Limits

  • Temperature Range:
    • Process: -40 to +80 °C (-40 to +176 °F)
    • Ambient: -40 to +80 °C (-40 to +176 °F)
    • Storage: -40 to +80 °C (-40 to +176 °F)
  • Pressure Range: 0.7 to 3 bar abs. (10.15 to 43.5 psi abs.)
  • Blocking Distance: 0.35 m (1.1 ft) for liquids and bulk solids.

Measurement Capabilities

  • Maximum Measuring Range:
    • Liquids: 8 m (26 ft)
    • Bulk solids: 3.5 m (11 ft)
  • Measured Variable: Distance (D) between sensor membrane and product surface. Can be converted to Level (L), Volume (V), or Flow (Q) with linearization.
  • Operating Frequency: Approximately 50 kHz.
  • Maximum Sound Pressure Level: 143 dB directly in front of the sensor.

Performance Characteristics

  • Measured Value Resolution: 1 mm (0.04 in).
  • Maximum Measured Error: ±0.2 % of the maximum sensor span under reference operating conditions.
  • Measuring Error: ±2 mm (±0.08 in) or 0.2 % of the measured distance (empty calibration), whichever is larger.
  • Response Time: Minimum ≥ 2 s (two-wire version).
  • Pulse Frequency: ≤ 0.5 Hz (two-wire version).

Electrical

  • Output Signal: 4 to 20 mA with HART protocol.
  • Supply Voltage (Two-wire version, HART):
    • Standard: 14 to 36 V (at 4 mA), 8 to 36 V (at 20 mA).
    • Ex ia: 14 to 30 V (at 4 mA), 8 to 30 V (at 20 mA).
    • Ex d: 14 to 30 V (at 4 mA), 11 to 30 V (at 20 mA).
  • Power Consumption (Two-wire version): 51 to 800 mW.
  • Current Consumption (Two-wire version): 3.6 to 22 mA.
  • Load: Minimum load for HART communication: 250 Ω.
  • Output Damping: User-defined, 0 to 255 s.

Mechanical / Hydraulic

  • Process Connections: Thread 2", Thread NPT 2" - 11.5.
  • Sensor Material: PVDF.
  • Seal Material: EPDM.
  • Housing Materials: T12 and F12 housing: AlSi10Mg powder-coated.
  • Weight: Approximately 2.6 kg (5.73 lb).
  • Degree of Protection: IP68 / NEMA 6P (housing closed, 24 h at 1.83 m water), IP66 / NEMA 4X (housing closed), IP20 / NEMA 1 (housing open, display).

Operability

  • Languages: 7 languages supported (de, en, es, fr, ja, it, nl).
  • Local Operation: Via display and operating module (VU331).
  • Remote Operation: Via personal computer (FieldCare, Commubox, etc.) or industrial handheld terminal (Field Xpert).

Environment

  • Ambient Temperature Range: -40 to +80 °C (-40 to +176 °F). LCD display functionality limited below -20 °C and above +60 °C.
  • Storage Temperature: -40 to +80 °C (-40 to +176 °F).
  • Thermal Shock Resistance: According to DIN EN 60068-2-14; test Nb: +80 to –40 °C, 1 K/min, 100 cycles.
  • Climate Class: DIN EN 60068-2-38 (Test Z/AD); DIN/IEC 68 T2-30Db.
  • Vibration Resistance: DIN EN 60068-2-64/IEC 68-2-64: 20 to 2000 Hz, 1 (m/s²)²/Hz; 3 x 100 min.
  • Electromagnetic Compatibility: According to EN 61326 series and NAMUR Recommendation EMC (NE 21).

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.