One rod probe 11371

Engineering summary from PDF text extraction for One rod probe 11371. Verify every value with the OEM datasheet.

Summary

Product identification

  • Product: Rod probe 11371
  • Type: Conductive level limit detection, partially insulated probe
  • Application: For use in liquid foodstuffs, such as milk, beer, fruit juice.

Application

  • Conductive level limit detection in process or storage tanks for all kinds of liquids.
  • Suitable for minimum or maximum detection in tanks.
  • Can be used as pump protection in pipes.
  • Capable of two-point control.

Operating limits

  • Process temperature (operating): –10°C to +100°C (10°F to 210°F)
  • Process temperature (cleaning): +150°C (300°F) (max. 30 min)
  • Process pressure (operating): –1 bar to +10 bar (–14.5 psi to +150 psi)
  • Maximum process pressure: 10 bar (150 psi)
  • Conductivity of liquid: min. 0.02 mS/cm

Feed water

  • Conductivity of liquid: min. 0.02 mS/cm

Product water

  • Not applicable

Electrical

  • Output: Probe provides current, supplied by Nivotester FTW325.
  • Electrical connection: Two terminals for wires with spade terminals (M4 screws).
  • Cable gland: M16, suitable for cable diameters from 5.5 mm to 10 mm.

Mechanical / hydraulic

  • Design: Rod probe
  • Probe diameter: 8 mm
  • Probe length: 50 mm to 2000 mm (measured from the lower edge of the process connection)
  • Partial insulation: 20 mm shorter than probe length, max. 180 mm.
  • Process connections:
    • Welded boss
    • Threaded boss G½ A
    • Threaded boss G¾ A
  • Housing: Hex-nut 41AF
  • Materials:
    • Probe rod: Stainless steel 1.4571 (AISI 316 Ti)
    • Welded boss: 316L (1.4435)
    • Threaded bosses (G½", G¾"): 316 Ti
    • Partial insulation: 0.2 mm PFA, sinter-fused
    • Gasket (process connection): Silicone
    • Cable gland: Brass, nickel-plated, with silicone gasket
  • Ingress protection: With M16 x 1.5 cable gland: IP66/ IP68 (1m, 1h) to EN 60529
  • Weight:
    • Weld-in socket: 0.59 kg
    • Thread G½: 0.53 kg
    • Without process connection: 0.41 kg
    • Thread G¾: 0.50 kg
    • Additional weight per 10 cm probe length (316 Ti + PFA): 0.04 kg/dm

Ambient conditions

  • Ambient temperature range: –20°C to +120°C (0°F to 250°F)
  • Storage temperature: –20°C to +120°C (0°F…250°F)