Datasheet summary
Silopilot M FMM50
Engineering summary from PDF text extraction for Silopilot M FMM50. Verify every value with the OEM datasheet.
Summary
Product identification
Product: Silopilot FMM50 Type: Electromechanical level system
Application
The Silopilot FMM50 is a level meter for bulk solids and fluids, offering a measuring principle independent of physical properties like mass density. It is suitable for:
- Measuring level in bunkers and silos with powdered, fine, or coarse grain bulk solids.
- Measuring level in vessels containing liquids.
- Level measurements up to 90 m.
- Applications with process temperatures up to +230 °C (+446 °F).
- Applications with process pressures up to 3 bar (43.5 psi) absolute.
- Use in aggressive atmospheres, such as acidic or caustic vapors.
- Separation layer detection in fluids with suitable sensing weights.
Benefits
- Suitable for process conditions where ultrasonic or radar level meters may fail.
- Precise level detection with an accuracy of ±5 cm or ±1 pulse.
- Compact transmitter with 0/4 - 20 mA current output and programmable signal outputs (e.g., counter pulse).
- Local operation via a 4-line text display with menu guidance.
- Digital minimum fail-safe control prevents sensor weight from damaging conveying systems.
Operating limits
- Process Temperature:
- -20 to +70 °C (-4 to +158 °F) (Option 1)
- -20 to +150 °C (-4 to +302 °F) (Option 2)
- -20 to +230 °C (-4 to +446 °F) (Option 3)
- Maximum process temperature at the unit from the bottom of the adaptor flange upwards is +70 °C (+158 °F).
- Process Pressure:
- 0.8 to 1.1 bar (12 to 16 psi) absolute (Option 1)
- 0.8 to 3.0 bar (12 to 43 psi) absolute (Option 2)
- Ambient Temperature:
- -20 to +70 °C (-4 to +158 °F)
- -40 to +70 °C (-40 to +158 °F) with self-regulating device heater.
- Storage Temperature: -40 to +80 °C (-40 to +176 °F).
- Maximum Measuring Range: 90 m.
Measuring principle
The FMM50 operates by lowering a sensing weight. When the weight contacts the medium, a motor tilts, signaling the electronics to stop the motor. The weight is then pulled up, and the distance is measured by counting pulses from the measuring tape.
Input
- Measured Variable: Distance from the flange to the product surface.
- Calculated Process Values: Filling level, residual volume, volume, or mass (with linearization).
- Safety Variables: Security distance, safety distance.
- Input Signal: Remote operation via two inputs (active or passive).
- Active Inputs: 12 to 24 V DC, normally open or normally closed.
- Passive Inputs: Max. 0.3 W / 30 V DC, normally open or normally closed.
- Start pulse length: min. 200 ms.
Performance characteristics
- Measured Value Resolution: ±5 cm or ±1 pulse.
- Maximum Measured Error: Corresponds to the measured value resolution.
- Measurement Cycle Time: Minimum 1 minute, with recommended minimum of 5 minutes for periodic measurements. Time depends on ambient temperature and measuring range.
- Tape Running Speed: 0.21 to 0.35 m/s.
Output
- Output Signal:
- Current Output: 0/4 to 20 mA (programmable, active). Max. 22 mA.
- Relay Outputs: 2 (optional 6). Contact load: max. 250 V AC / 6 A.
- Programmable Relay Functions: Measurement cycle, counter pulse, reset pulse, band return, running up, top position, measuring, alarm, service interval, threshold.
- Signal on Alarm: Local display (error symbol, code, text), current output (minimum, maximum, programmable, or hold), or relay output (alarm function).
- Load (Current Output): Max. 600 Ω.
Electrical
- Supply Voltage:
- 180 to 253 V AC, 50/60 Hz (Option 1)
- 90 to 127 V AC, 50/60 Hz (Option 2)
- Power Consumption: Max. 230 VA (Option A or C) or 250 VA (Option B or D).
- Terminals: Max. 2.5 mm² (Supply voltage), Max. 1.5 mm² (Signal inputs, relay outputs, current output).
Mechanical / Hydraulic
- Dimensions: See figures 10, 11, 12, 13, 14.
- Weight: 22 to 28 kg (device only, without sensing weight).
- Materials:
- Housing: Aluminum (optional coated).
- Wiper: Aluminum/steel or stainless steel.
- Measuring tape: Stainless steel or plastic.
- Sensing weights: Various materials including steel, stainless steel, Polyester, PVC.
- Process Connection: Flange, hole dimensions DN100 PN16 according to EN 1092-1.
- Cable Entries: M25x1.5, clamping range 10 to 17 mm.
- Degree of Protection: IP67 (closed housing), IP65 (closed housing with external start button), IP20 (open housing).
Mounting
- Mounting Location: Select location to prevent product covering or damaging the sensing weight or tape. Consider inflow/outflow cones and avoid fixtures.
- Mounting Position: Typically mounted on a counter flange DN100 PN16. Device can be mounted horizontally (max. 2° inclination).
Environment
- Electromagnetic Compatibility: Interference emission and immunity to EN 61326.
- Vibration: Device should not be exposed to vibration to prevent measurement errors.
Operability
- Operation Concept: Operator-oriented menu structure with commissioning, operation, diagnostics, and expert levels.
- On-site Operation: Local operation via 3 push buttons for configuration and 1 push button for starting measurements. Optional external start button.
- Display: 4-line, 20 characters per line, contrast adjustable. Numeric and graphic display of measurand. Permitted ambient temperature for display: -20 to +60 °C.
- Languages: English, German, French, Japanese. Other languages available optionally.
Certificates and approvals
- CE Mark: Conforms to applicable EU Directives.
- Ex Approval: Data listed in separate documentation.
- RoHS: Complies with substance restrictions of Directive 2011/65/EU and Delegated Directive 2015/863/EU.
Ordering information
Detailed ordering information is available via the Endress+Hauser website Product Configurator or sales center.
Accessories
Various accessories are available, including:
- Weather protection cover.
- Process adapter extensions for higher temperatures.
- Adapter flanges for different pressure ratings and nominal diameters.
- Sensing weights for interface measurement.
- Chain to increase block distance.
- Removal tool and tape stopper.
Disclaimer: This extraction may miss figures, footnotes, or revisions; contractual data must match the OEM PDF revision used on the project.