Datasheet summary
Solimotion FTR20
Engineering summary from PDF text extraction for Solimotion FTR20. Verify every value with the OEM datasheet.
Summary
Product identification
Solimotion FTR20 Flow indicator for bulk solids
Application
- Flow indicator for monitoring pneumatic and mechanical transport processes of bulk solids.
- Non-contact detection: use in containers, pipelines, shafts or free-fall shafts (detection from the outside is possible for non-metallic container materials).
Operating limits
- Process temperature range: -40 to +450 °C (-40 to +842 °F) with optional high temperature adapter.
- Process pressure range:
- 0.5 to 6.8 bar (7 to 99 psi) absolute (direct process mounting only).
- 0.8 to 5.1 bar (12 to 74 psi) absolute (with optional high temperature adapter).
- 0.5 to 21 bar (7 to 305 psi) absolute (with optional high pressure adapter).
Input
- Measured variable: Doppler frequency.
- Measuring range (Detection range): Maximum range is 20 m depending on bulk solids, with an unobstructed radiation path to the surface. The range also depends on the container walls to be penetrated.
- Operating frequency: 24 GHz ISM.
- Transmitting power: Maximum 100 mW e.i.r.p. (equivalent isotrope radiation performance).
- Power density directly in front of the device: Approx. 1 mW/cm².
- Power density at a distance of 1 m: Approx. 0.3 µW/cm².
- Switching frequency: Max. 2 Hz.
- Antenna opening angle (3 dB): Approx. ±11°.
- Detectable speed: 0.09 to 62 m/s (3.54 to 2441 in/s).
Output
- Output signal:
- Potential-free relay changeover contact (A).
- Switching contact semiconductor relay (B).
- Current 4-20 mA (C).
- Switching output:
- Relay: Max. switching capacity 250 V AC / 4 A, 125 V DC / 0.4 A or 30 V DC / 4 A. (Harting connector: 30 V AC / 60 V DC).
- Solid-state relay: Max. switching capacity 30 V AC / 0.4 A or 40 V DC / 0.4 A.
- Switching delay: Parameterizable from 100 ms to 20 s.
- Switching hysteresis: Adjustable.
- Current output: 4-20 mA, active. Load max. 600 Ω. The value of the current output corresponds to the signal strength.
Power supply
- Supply voltage:
- 85 to 253 V AC, 50/60 Hz.
- 20 to 60 V DC or 20 to 30 V AC, 50/60 Hz.
- The electrical connection with a connector is only available for the power supply with 20 to 60 V DC or 20 to 30 V AC, 50/60 Hz (ordering option "E").
- Power consumption:
- 9 VA (85 to 253 V AC, 50/60 Hz).
- 2.4 W (20 to 60 V DC) / 4 VA (20 to 30 V AC, 50/60 Hz).
Mechanical construction
- Dimensions: L1, L2, L3 dimensions vary based on housing and electrical connection type.
- Weight: Maximum 1.7 kg (3.75 lb), depending on housing and process connection. Variants with encapsulated electronics weigh an additional 0.2 kg (0.44 lbs).
- Materials: Stainless steel (316Ti, 316L), Aluminum, Plastic, Die-cast zinc, Brass (nickel-plated). Specific material usage depends on housing and component.
- Process connection:
- R 1½ in accordance with EN 10226.
- 1½ NPT in accordance with ANSI/ASME.
- G 1½ in accordance with ISO 228-1.
Environment
- Ambient temperature: -40 to +70 °C (-40 to +158 °F).
- Storage temperature: See ambient temperature.
- Humidity: Operation up to 100%. Do not open in a condensing atmosphere.
- Operating height: Up to 2000 m (6600 ft) above sea level.
- Degree of protection: IP66 (with closed housing), IP20 (with open housing).
- Pollution degree: Pollution degree 2.
- Electromagnetic compatibility:
- Interference emission to EN 61326, Electrical Equipment Class B.
- Interference immunity to EN 61326, Appendix A (Industrial).
Certificates and approvals
- CE mark.
- Ex approval (data in separate documentation).
- RoHS compliant (2011/65/EU and 2015/863/EU).
- Telecommunications: EN 300440.
- Food suitability: Meets requirements of EU Regulation 1935/2004 and 2023/2006 for some device variants.
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.