Back to Endress + Hauser Level measurement
Endress+Hauser logo

Datasheet summary

Soliphant T FTM20

Engineering summary from PDF text extraction for Soliphant T FTM20. Verify every value with the OEM datasheet.

Summary

Product identification

  • Product Name: Soliphant T FTM20, FTM21
  • Type: Vibronic point level switch for bulk solids.
  • Application: Suitable for fine-grained or coarse-grained, non-fluidised bulk solids. Available with certificates for use in dust incendive hazard areas.
  • FTM20: Compact design, 250 mm vibrating rod, installation in any direction.
  • FTM21: Vibrating rod with extension pipe in lengths of 500 mm, 1000 mm, 1500 mm, installation in any direction.
  • Typical applications: Cereals, coffee beans, sugar, animal feed, rice, detergents, dye powder, chalk, gypsum, cement, sand, plastic granules.

Benefits

  • No calibration required ("plug and play")
  • Insensitive to build-up, maintenance-free
  • No mechanically moving parts, wear-free, long operating life
  • Sensor material 316L offers resistance to abrasion
  • F16 plastic housing with sight glass (F18 aluminium housing also available)
  • Insensitive to external vibration and flow noises
  • Available with explosion protection (ATEX II 1/3 D, FM, or CSA approval)

Measuring Principle

The device uses a piezoelectric drive to excite a vibrating rod to its resonance frequency. If the medium covers the rod, its vibration amplitude changes (damps). The electronics compare this amplitude to a set value to indicate if the rod is vibrating freely or is covered by medium.

Measuring System

The Soliphant T is a compact electronic switch consisting of the Soliphant T unit (FTM20 or FTM21 with FEM22 or FEM24 electronic insert) and connection to a supply point and control systems.

Cable Specifications

  • Temperature Resistance: Connecting cables must withstand an ambient temperature of +20 K.
  • Cable Entries: M20x1.5 (cable gland), NPT ½, G ½.

Input

  • Measured Variable: Level (dependent on mounting location and extension pipe length).
  • Measuring Range: Dependent on mounting location and selected pipe extension length (500 mm, 1000 mm, 1500 mm).
  • Measuring Frequency: 700...800 Hz.

Output

  • Galvanic Isolation:
    • FEM22: Between sensor and power supply.
    • FEM24: Between sensor, power supply, and load.
  • Switch Behaviour: Binary.
  • Power-on Behaviour: Output initially set to "signal on alarm" for max. 3 s, then switches to the correct output signal.
  • Fail-safe Mode:
    • MAX: Output switches to "signal on alarm" when the vibrating rod is covered (for overfill protection).
    • MIN: Output switches to "signal on alarm" when the vibrating rod becomes exposed (for empty running protection).
    • Switchable at the electronic insert.
  • Switching Delay: 0.5 s (sensor covered), 1 s (sensor exposed).
  • Ex Specifications: FEM22, FEM24 support explosion protection for dust-air mixtures (Dust-Ex, DIP).

FEM22 electronic insert (DC PNP)

  • Power Supply: 10…45 V DC, Ripple max. 5 V (0…400 Hz).
  • Current Consumption: Max. 18 mA.
  • Power Consumption: Max. 0.81 W.
  • Separation Voltage: 2.2 kV.
  • Overvoltage Protection: Category II.
  • Electrical Connection: Three-wire DC connection with cable entry / M12 plug.
  • Output Signal: Positive signal at output (PNP), output blocked at point level.
  • Signal on Alarm (Device Failure/Power Failure): < 100 μA.
  • Connectable Load:
    • Load current: Max. 350 mA (cyclical overload and short-circuit protection).
    • Max. load voltage: 45 V.
    • Residual current: < 100 μA (transistor blocked).
    • Capacitive load: Max. 0.5 μF (at 45 V), Max. 1.0 μF (at 24 V).
    • Residual voltage: < 3 V (transistor switched through).

FEM24 electronic insert (AC/DC with relay output)

  • Power Supply: 19…253 V AC (50/60 Hz) or 19…55 V DC.
  • Power Consumption: Max. 1.3 W.
  • Separation Voltage: 2.2 kV.
  • Overvoltage Protection: Category II.
  • Electrical Connection: Universal current connection with relay output (DPDT).
  • Output Signal: Relay output.
  • Signal on Alarm (Power Failure): Relay de-energised.
  • Connectable Load:
    • AC: Max. 6 A, Max. 253 V; Max. 1500 VA (cos φ = 1), Max. 750 VA (cos φ > 0.7).
    • DC: Max. 6 A to 30 V, Max. 0.2 A to 125 V.
    • For functional extra-low voltage circuits (double insulation): Sum of relay output and power supply voltages max. 300 V.

Operating Conditions

  • Ambient Temperature Range: –40 to +70 °C (–40 to +158 °F).
  • Storage Temperature: –40 to +85 °C (–40 to +185 °F).
  • Climate Class: As per DIN IEC 68 Part 2-38, Fig. 2a.
  • Degree of Protection: IP66/IP67, NEMA4X.
  • Vibration Resistance: DIN 60068-2-27 / IEC 68-2-27: shock 30 g; vibration 0.01 g²/Hz.
  • Electrical Safety: IEC 61010, CSA 1010.1-92, FM3600.
  • Electromagnetic Compatibility:
    • Interference emission: EN 61326, Class B.
    • Interference immunity: EN 61326, Annex A (Industrial).
  • Installation Height: Up to 2000 m (6600 ft) above sea level.
  • Thermal Shock Resistance: Maximum 120 K.
  • Limiting Medium Pressure Range: –1 to 25 bar (–14.5 to 362.5 psi).
  • Maximum Working Pressure (MWP): 25 bar (362.5 psi).
  • Burst Pressure: 100 bar (1450 psi).
  • Grain Size: ≤ 25 mm.
  • Bulk Density: ≥ 200 g/l, not fluidised.

Mechanical Construction

  • Design, Dimensions: Available in compact (FTM20) and pipe extension versions (FTM21) with lengths of 500 mm, 1000 mm, 1500 mm.
  • Weight:
    • FTM20/FTM21 with F16 housing, FEM24 and R 1 thread: Approx. 1.0 kg (2.21 lbs).
    • 500 mm extension: Approx. 1.3 kg (2.87 lbs).
    • 1000 mm extension: Approx. 2.0 kg (4.41 lbs).
    • 1500 mm extension: Approx. 2.6 kg (5.73 lbs).
  • Material:
    • F16 Housing: Polyester.
    • F18 Housing: Aluminium EN-AC-AlSi10Mg.
    • Process connections: R1, R1½ (316L), NPT 1¼, NPT 1½ (316L).
    • Sensor: 316L.

Operability

  • Display Elements:
    • FEM22: One green LED (operation), one yellow LED (electronic switch closed).
    • FEM24: One green LED (operation), one yellow LED (contact closed/relay energised).
  • Operating Elements: Switches for safety mode (MAX/MIN) and bulk density/density setting (200 g/l or 400 g/l).

Certificates and Approvals

  • CE Mark: Declaration of Conformity available.
  • Ex Approval: Information on Ex versions available from sales centers; separate documentation provided. Approvals include ATEX II 1/3 D, CSA, FM, IEC Ex, NEPSI, EAC Ex.
  • Other Standards and Guidelines: Low Voltage Directive (73/23/EEC), DIN EN 61010 Part 1, EN 61326.
  • Pressure Equipment Directive (PED) 2014/68/EU: Applicable for pressure instruments with permitted pressure ≤ 200 bar. Devices without a pressure-bearing housing are outside the scope.
  • RCM Tick Mark: Complies with Australian Communications and Media Authority regulations.
  • EAC Conformity: Meets legal requirements of applicable EAC Directives.
  • RoHS: Complies with EU Directive 2011/65/EU.

Accessories

  • Sliding Sleeve: Available for pressurized and unpressurized containers.

Spare Parts

  • FEM22 electronic insert: 52025688
  • FEM24 electronic insert: 52025691
  • Covers for F16 and F18 housings.

Supplementary Documentation

  • Operating Instructions: KA00227F
  • Certificates: ATEX, IECEx, NEPSI.

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.