Datasheet summary
Soliwave FDR16
Engineering summary from PDF text extraction for Soliwave FDR16. Verify every value with the OEM datasheet.
Summary
Product identification
- Product Name: Soliwave FDR16/FQR16
- Type: Ultra-compact microwave barrier for non-contact point level detection
Application
- Point level switch for bulk solids, liquids, and piece goods.
- Suitable for use in explosive areas.
- Detection from the outside is possible for non-metallic container materials.
Operating limits
- Process temperature range: -20 to +450 °C (-4 to +842 °F) with optional high temperature adapter.
- Process pressure range: 0.5 to 21 bar (7 to 305 psi) absolute with optional high pressure adapter.
Input
- Measured variable: Absorption of radiated electromagnetic waves.
- Measuring range (Detection range): Up to 20 m (787.4 in) with free path between FQR16 and FDR16. Range is also dependent on container walls.
- Operating frequency: 24.15 to 24.25 GHz.
- Transmitting power: Maximum 100 mW e.i.r.p.
Output
- Switching output:
- 3-wire DC-PNP (positive voltage signal).
- 2 DC-PNP outputs, antivalent switched.
- Max. 200 mA per output, short-circuit proof.
- Switching delay parameterizable from off to 10 seconds.
- Safety-related circuit: MIN or MAX point level detection with electric switch opening on reaching point level, or in case of malfunctions or power failure.
Power supply
- Supply voltage: 18 to 30 V DC.
- Power consumption: ≤ 2.4 W.
- Current consumption: ≤ 120 mA (without load).
- The power supply of the FDR16 is provided by the FQR16.
Electrical connection
- Via M12 connectors.
Performance characteristics
- Ambient temperature: -20 to +60 °C (-4 to +140 °F).
- Storage temperature: See ambient temperature.
- Degree of protection: IP69, IP67.
- Vibration resistance: Vibration according to EN 60068-2-6; Shock resistance according to EN 60068-2-27.
- Electromagnetic compatibility: Interference emission to EN 61326 Class B; Interference immunity to EN 61326, Appendix A (Industrial).
- Reverse polarity protection: Integrated.
Process
- Process temperature: -20 to +60 °C (-4 to +140 °F); up to +450 °C (+842 °F) with optional high temperature adapter.
- Process pressure:
- 0.5 to 6.8 bar (7 to 99 psi) absolute (direct process mounting).
- 0.8 to 5.1 bar (12 to 74 psi) absolute (with optional high temperature adapter).
- 0.5 to 21 bar (7 to 305 psi) absolute (with optional high pressure adapter).
Mechanical construction
- Materials: Stainless steel 316L (1.4404) housing and process connection, PTFE transmission windows.
- Process connection: G 1 and G 1½ (ISO 228-1), 1½ NPT (ANSI/ASME).
- Weight: Maximum 1.7 kg (3.75 lb), depending on housing and process connection.
Operability
- Adjustable sensitivity.
- Switching delay: off, 500 ms to 10 s.
- LED signal strength indicator for adjustment and positioning.
Certificates and approvals
- CE mark: Meets applicable EU directives.
- Ex approval: Refer to separate Ex documentation.
- RoHS: Complies with EU Directives 2011/65/EU and 2015/863/EU.
- Food suitability: Materials in contact with the process meet EU Regulations 1935/2004 and 2023/2006.
Accessories
A range of accessories are available, including:
- Prefabricated cables (various lengths, IP67/IP69).
- Operating magnet.
- Counternut.
- Mounting bracket.
- Welding sleeve.
- Weld-in adapter.
- Mounting flange.
- High pressure adapter.
- High temperature adapter and extensions.
- Plugs.
- Sight glass fittings.
- Insertion adapters.
- Weld-in nozzles.
Disclaimer: Extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.