Back to Endress + Hauser Level measurement
Endress+Hauser logo

Datasheet summary

Soliwave FDR56

Engineering summary from PDF text extraction for Soliwave FDR56. Verify every value with the OEM datasheet.

Summary

Product identification

Soliwave FDR56/FQR56: Compact microwave barrier for non-contact limit detection for bulk solids and liquids.

Application

  • Point level switch for bulk solids and liquids, also for counting piece goods and in explosive areas.
  • Detection can be made from the outside for non-metallic container materials.

Operating limits

  • Process temperature range: -40 to +450 °C (-40 to +842 °F) with optional high temperature adapter.
  • Process pressure range:
    • 0.5 to 6.8 bar (7 to 99 psi) absolute (direct process mounting).
    • 0.8 to 5.1 bar (12 to 74 psi) absolute (with optional high temperature adapter).
    • 0.5 to 21 bar (7 to 305 psi) absolute (with optional high pressure adapter).

Input

  • Measured variable: Absorption of electromagnetic waves.
  • Measuring range (Detection range): Maximum 100 m (3937 in) with free path between FQR56 and FDR56. Range depends on container walls to be penetrated.
  • Operating frequency: 24 GHz ISM.
  • Transmitting power: Maximum 100 mW e.i.r.p.
  • Switching frequency: Max. 4 Hz.
  • Antenna opening angle (3 dB): Approx. ±11°.

Output

  • Output signal:
    • Potential-free relay changeover contact.
    • Switching contact semiconductor relay.
    • 4-20 mA current output.
  • Switching output:
    • Relay: Max. 250 V AC / 4 A, 125 V DC / 0.4 A or 30 V DC / 4 A.
    • Solid-state relay: Max. 30 V AC / 0.4 A or 40 V DC / 0.4 A.
    • Switching delay: Parameterizable from 100 ms to 20 s.
    • Switching hysteresis: Adjustable.
  • Current output:
    • 4-20 mA, active.
    • Load: Max. 600 Ω.

Power supply

  • Supply voltage:
    • 85 to 253 V AC, 50/60 Hz.
    • 20 to 60 V DC or 20 to 30 V AC, 50/60 Hz.
  • Power consumption:
    • FQR56: 7 VA (AC) or 1 W (DC) / 1.5 VA (AC).
    • FDR56: 9 VA (AC) or 2.4 W (DC) / 4 VA (AC).

Mechanical / hydraulic

  • Process connection:
    • R 1½ (EN 10226).
    • 1½ NPT (ANSI/ASME).
    • G 1½ (ISO 228-1).
  • Dimensions: See diagram. Length dimensions (L1-L3) depend on housing and electrical connection.
  • Weight: Max. 1.7 kg (3.75 lb).
  • Materials: Stainless steel (316Ti, 316L), Aluminum, Plastic, Die-cast zinc, Brass.

Environment

  • Ambient temperature: -40 to +70 °C (-40 to +158 °F).
  • Storage temperature: See ambient temperature.
  • Humidity: Operation up to 100%.
  • Operating height: Up to 2000 m (6600 ft).
  • Degree of protection: IP66 (closed housing), IP20 (open housing).
  • Pollution degree: 2.

Performance characteristics

  • Vibration resistance: Sine excitation, 5 to 500 Hz, 5.5 mm peak / 5 g.
  • Shock resistance: Half sine, 18 ms, 30 g.

Certificates and approvals

  • CE mark.
  • Ex approval (data in separate documentation).
  • RoHS compliant.

Disclaimer: This summary is based on extracted text which may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.