Datasheet summary
Chemoclean CYR10B
Engineering summary from PDF text extraction for Chemoclean CYR10B. Verify every value with the OEM datasheet.
Summary
Product identification
Chemoclean CYR10B Cleaning injector for universal use with dosing function for cleaning sensors.
Application
- Operation of cleaning systems with separate cleaning nozzle.
- Execution of automatic cleaning cycles in retractable assemblies.
Features & Benefits
- Easy handling of rinsing medium via concentrate dosing with motive water (water jet pump).
- Cleaning and rinsing cycles without an additional dosing pump.
- Adjustable dosing ratio of motive water to cleaning concentrate.
- Excellent chemical resistance due to plastic rinsing block.
- Easily fastened on wall or mounting plate.
- Designed for automatic sensor cleaning systems with Liquiline CM442/444/448.
Operating principle
The cleaning injector uses the Venturi principle to mix motive water and cleaner. Motive water flows through a water jet pump, creating negative pressure that draws in and mixes the cleaner. Two solenoid valves, controlled by the Liquiline CM44x, regulate the flow rate of motive water and cleaner. A metering screw allows for adjustment of the mixture ratio.
Measuring System
A complete measuring system includes:
- 1 cleaning injector CYR10B
- Transmitter Liquiline CM44x (with sensor, at least 2 relays and Chemoclean function)
- Assembly with mounted spray cleaning (e.g., CYA112 with spray cleaning 71158245 / 71158246)
For systems with Cleanfit Control CYC25:
- 1 cleaning injector CYR10B
- Cleanfit Control CYC25 (with pneumatic pilot valve)
- Liquiline CM44x (with sensor, at least 4 relays and Chemoclean Plus; optional 2 digital inputs for feedback)
- Pneumatically controlled retractable assembly (e.g., Cleanfit CPA875 or CPA871)
Electrical
- Supply voltage versions: 24 VDC, 115 VAC, 230 VAC.
- Power consumption:
- 24 V version: 16 W total (2 x 8 W for solenoid valves).
- 115 V version: 16 VA total (2 x 8 VA for solenoid valves).
- 230 V version: 16 VA total (2 x 8 VA for solenoid valves).
- Cable specification:
- Cable diameter: 6.0 to 8.0 mm.
- Cable cross-section: 0.25 to 1.5 mm².
- Maximum cable length (CYR10B to CYC25 or CM44x): 30 m.
Mechanical / Hydraulic
- Dimensions: See diagram in extracted text.
- Weight: 2 kg.
- Materials:
- Housing block: PVC.
- Hose nozzles: PVC.
- Valve head 6213: EPDM, stainless steel.
- Valve head 0331: EPDM, PP.
- Seals: EPDM, PTFE.
- Check valve: Glass.
- Hose specifications:
- Hose for cleaning mixture: Diameter 16 (G 3/8).
- Hose for cleaner: Diameter 12 (G 1/4).
- Hose for motive water: Diameter 16 (G 3/8).
- Maximum hose length (CYR10B to cleaner vessel): 3 m.
- Maximum delivery head (CYR10B to cleaner vessel): 3 m.
Operating Limits
- Ambient temperature range: –5 to +40 °C.
- Storage temperature range: –40 to +60 °C.
- Humidity: 0 to 95 %, non-condensating.
- Operating altitude: < 2000 m.
- Degree of protection: IP65.
- Medium temperature (process): max. 60 °C.
- Motive water pressure: 2 to 10 bar.
- Medium counterpressure: max. 3 bar.
- Suction height of cleaner: max. 3 m.
- Mixture ratio (cleaner : motive water): 1 : 4 to 1 : 17.
- Motive water flow range: 2 to 10 l/min.
- Motive water particle size: > 100 µm. A water filter is recommended.
Installation
- Mounting location: Can be wall-mounted using suitable fastening equipment (max. screw diameter 9 mm).
- Hose lines: Hose clips are required for attaching hoses to the device nozzles.
- Process connections: Requires connection of hose for cleaning mixture, cleaner vessel, motive water supply, and backflow valve. Customer must provide hoses, backflow valve, and dirt trap.
Accessories
- Cleanfit CPA472D
- Cleanfit CPA473
- Cleanfit CPA474
- Cleanfit CPA871
- Cleanfit CPA875
- Flexdip CYA112
- Flexdip CYH112
Disclaimer This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.