Datasheet summary
CleanFit CUA451
Engineering summary from PDF text extraction for CleanFit CUA451. Verify every value with the OEM datasheet.
Summary
Product identification
- Product Name: Cleanfit CUA451
- Type: Manually operated retractable assembly for water, wastewater and process media.
- Document: TI00369C/07/EN/15.21
Application
This assembly is designed for use in:
- Drinking water and process water: Filter monitoring and backflushing, phase separation monitoring, raw water monitoring, and sludge treatment in water works.
- Wastewater treatment plants: Sludge monitoring in recirculation lines, sludge centrifuge monitoring, primary sludge, and sludge treatment.
- Process media from all kinds of industry: Raw water and process water monitoring, cooling water monitoring, recirculation lines, and sludge treatment.
Operating limits
- Maximum process pressure: 10 bar (145 psi)
- Manual insertion/retraction pressure: Maximum 2 bar (29 psi)
- Ambient temperature: 0 to 50 °C (32 to 122 °F)
- Medium temperature: 0 to 85 °C (32 to 185 °F)
Mechanical / hydraulic
- Process connection:
- G2" female thread
- G2" female thread with weld-in adapter
- Flange DN 50 / PN 16 (as per EN 1092-1) and flange ANSI 2" / 150 lbs
- Rinse connection and vent cock:
- Options include ball valves with hose connections (OD 9mm), customer-provided G1/8 external thread connections, or G1/8 internal threads.
- Weight: 8 to 11 kg (17.6 to 24.3 lbs), depending on version.
- Wetted materials: Viton (seals), Stainless steel 1.4404 (AISI 316 L), Nickel-plated brass (vent cock or rinse connection).
- Not wetted materials: Stainless steel 1.4404 (AISI 316 L).
Installation
- Orientation: Ideally mounted in an ascending pipe; horizontal installation is also possible. Avoid installation in down pipes, areas prone to air collection, foaming, or settling of suspended particles.
- Minimum pipe diameter: DN 80.
- Uniform flow conditions: Installation in areas with uniform flow is recommended.
Certifications
- CE/PED: The assembly is manufactured according to good engineering practice as per Article 4, Paragraph 3 of the Pressure Equipment Directive 2014/68/EU and does not require a CE label.
Disclaimer
This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.