Datasheet summary
DipFit CPA140
Engineering summary from PDF text extraction for DipFit CPA140. Verify every value with the OEM datasheet.
Summary
Product identification
Immersion assembly with flange connection for demanding processes for the installation of 12 mm sensors.
- Product Name: Dipfit CPA140
- Document ID: TI00178C/07/EN/13.18
Application
- Chemical industry (e.g., synthetic materials, dyes, pesticides, fertilizers, oil/wastewater separation, condensate treatment)
- Power stations and incinerator plants (e.g., cooling water monitoring, flue gas cleaning)
- Metal extraction and metal processing
Your benefits
- Simple installation and removal with bayonet lock.
- Reliable sealing, even in media with solids.
- Suitable for high pressures and temperatures.
- Immersion depth from 500 to 2500 mm.
- Integrated potential matching pin (Alloy C4 or tantalum).
- Reduced condensation via breathable GORE-TEX® filter.
- 3 slots for 12 mm sensors and cleaning head.
- Chemical and ultrasonic cleaning can be retrofitted.
- Variety of flange connections (DIN, ANSI, JIS).
Function and system design
A complete measuring system comprises:
- Immersion assembly Dipfit CPA140
- 1-3 pH, ORP, pH/ORP combined, or temperature sensors (12 mm) (e.g., CPS11D, CPS12D)
- 1-3 measuring cables (e.g., CYK10, CPK9)
- Transmitter (e.g., Liquiline CM442)
- Optional: Extension cable (e.g., CYK11)
Environment
- Ambient temperature range: -10 to +70 °C (+10 to +160 °F)
- Storage temperature: -10 to +70 °C (+10 to +160 °F)
- Degree of protection: IP65
Process
Process temperature
- PVDF version: 0 to 120 °C (32 to 250 °F)
- Stainless steel version: -15 to 150 °C (5 to 300 °F) (for all seals except EPDM)
- Stainless steel version: -15 to 140 °C (5 to 280 °F) (for EPDM seal)
Process pressure
- PVDF version: Max. 6 bar (87 psi), absolute
- Stainless steel version: Max. 10 bar (145 psi), absolute
Pressure-temperature ratings
See the official PDF for exact tabulated values.
Mechanical construction
Materials
In contact with medium (depending on version):
- Immersion tube: PVDF / stainless steel 1.4404 (AISI 316L)
- O-rings: EPDM / VITON / Chemraz / Fluoraz
- Sensor holder: PVDF / stainless steel 1.4404 (AISI 316L)
- Potential matching pin: Alloy C4 / tantalum / stainless steel 1.4401 (AISI 316)
- Shock-protection stud: PVDF / stainless steel 1.4401 (AISI 316)
- Dummy plug: PEEK
Not in contact with medium (depending on version):
- Assembly head: PP-GF 20
- Lap joint flange: UP-GF / stainless steel 1.4404 (AISI 316L)
- Installation aids (stainless steel version only): Stainless steel 1.4301 (AISI 304)
Process connections
- Flange DN 80 / PN 16
- Flange ANSI 3" / 150 lbs
- Flange JIS 10K 80A
Cable glands
- 1 x Pg 13.5 and 2 x dummy plug Pg 16
Sensor mounting slots
- 3 x for 12 mm sensors
Immersion depth
- 500 mm (19.7 in)
- 1000 mm (39.4 in)
- 1500 mm (59.1 in)
- 2000 mm (78.7 in)
- 2500 mm (98.4 in)
Dimensions
See the official PDF for exact tabulated values for flange dimensions (DN80 PN16, ANSI 3" 150 lbs, JIS 10K 80A).
- Immersion depth (y): See Configurator on product page.
Weight
- PVDF version: 2.5 to 3.0 kg (5.5 to 6.6 lbs)
- Stainless steel version: 8.0 to 12.0 kg (17.6 to 26.5 lbs)
Certificates and approvals
- Pressure Equipment Directive: 2014/68/EU (manufactured according to good engineering practice, not CE-labeled).
- Inspection certificate: Test certificate 3.1 in accordance with EN 10204 available depending on version.
Accessories
Sensors (selection)
- Orbisint CPS11D / CPS11 (pH sensor)
- Ceraliquid CPS41D / CPS41 (pH electrode)
- Orbipore CPS91D (pH electrode)
- Orbisint CPS12D / CPS12 (ORP sensor)
- Ceraliquid CPS42D / CPS42 (ORP electrode)
- Memosens CPS16D (Combined pH/ORP sensor)
- Memosens CPS96D (Combined pH/ORP sensor)
- Oxymax COS22D / COS22 (Dissolved oxygen sensor)
- Memosens COS81D (Optical dissolved oxygen sensor)
Measuring cable
- Memosens data cable CYK10
- Memosens data cable CYK11 (Extension cable)
- Measuring cable CPK9
- Measuring cable CPK12
Electrolyte vessel
- CPY7B (200 ml)
Cleaning system
- Chemoclean CPR31 (Spray system)
- Cleaner up to 6 bar (87 psi) absolute, max. 30 °C (86 °F)