Back to Endress + Hauser Liquid analysis
Endress+Hauser logo

Datasheet summary

FlowFit W CUA250

Engineering summary from PDF text extraction for FlowFit W CUA250. Verify every value with the OEM datasheet.

Summary

Product Identification

  • Product Designation: CUA 120 or FlowFit W CUA 250
  • Description: Process and Flow Assemblies for Turbidity Measurement

Areas of Application

  • Discharge monitoring in communal and industrial wastewater
  • Sedimentation monitoring in wastewater treatment (coagulation and flocculation)
  • Recycling of industrial service water
  • Filter effluent and filter rupture monitoring
  • Clear rinse cycle monitoring
  • Flotation process monitoring
  • Monitoring of closed circuits (e.g., cooling water, product pipelines)

Operating Limits

  • Nominal Operating Range: 10 ... +55 °C
  • Limit Operating Range: 10 ... +60 °C
  • Storage Temperature Range: 20 ... +65 °C
  • Pressure Specification:
    • 25 °C / 6 bar
    • 50 °C / 3 bar
    • 60 °C / 1 bar

Mechanical / Hydraulic

  • CUA 120 Materials: PVC, stainless steel 1.4571
  • CUA 250 Materials: PVC
  • O-ring Seals: EPDM
  • Flange Adapter (CUA 120):
    • A: Adapter for welding flange (flange height h=47 mm)
    • B: Installation adapter (adapter height=93 mm)
  • Flow Assembly (CUA 250):
    • A: Installation with screw connections DN 25
    • B: Installation in pipe sections DN 63
  • Welding Socket Materials:
    • Stainless steel 1.4571 (Order no. 50080249)
    • Polyvinyl chloride (PVC) (Order no. 50080250)
    • Polypropylene (PP) (Order no. 50080251)

Installation Notes

  • Pipe Diameter: Must be at least DN 100 when using bright materials (VA or similar).
  • Sensor Placement: Install in areas with constant flow, avoiding air collection, foam formation, or suspended solids settling.
  • Sensor Orientation:
    • Generally, orient the sensor surface against the medium flow for increased self-cleaning effects, especially in heavily soiled media with turbidities > 15 FNU.
    • Orient the sensor parallel to the medium flow to minimize wall reflection effects for turbidities < 5 FNU, or in conjunction with the spray head CUR 3.
  • Horizontal Installation: If installed horizontally, orient the sensor at the 3 o'clock or 9 o'clock position to prevent air pockets.
  • Mounting: Ensure the O-ring seals properly. Align the sensor's acute-angled edge opposite the marking hole and pointing away from it.

Accessories

  • Chemoclean CUR 3: Spray head for CUA 250.
    • Materials/seals: EPDM / PVC, PVDF.
  • Spare Part Kit (CUY 2): For turbidity assemblies (connection to tubing or hose).
  • Cleaning Injector (CYR 10): With valves for drive water and cleaning agent.