Datasheet summary
Liquiline CM442-CM444-CM448
Engineering summary from PDF text extraction for Liquiline CM442-CM444-CM448. Verify every value with the OEM datasheet.
Summary
Product Identification
- Product Line: Liquiline
- Models: CM442, CM444, CM448
- Type: Multiparameter transmitter with up to eight measuring channels based on digital Memosens technology.
- Document: TI00444C/07/EN/27.24-00, Version 2024-08-01
Application
The Liquiline CM442/CM444/CM448 is designed for monitoring and controlling processes in various industrial and environmental sectors, including:
- Water and wastewater
- Power stations
- Chemical industry
- Other industrial applications
Key Features and Benefits
- Flexibility:
- Connects up to 8 Memosens sensors.
- Supports mathematics functions for calculating new measured values.
- Offers digital fieldbuses (HART, PROFIBUS, Modbus, Ethernet/IP, PROFINET) and an integrated web server.
- Provides choice of cleaning function, controller, and alarm relay.
- Optional digital or analog inputs/outputs.
- Process Safety: Standardized operating concept across the Liquiline, sampler, and analyzer platform.
- Commissioning: Fast commissioning due to Memosens technology (lab-calibrated sensors, hot plug-and-play) and preconfigured transmitters.
- Adaptability: Easy extension and adaptation capabilities.
- Inventory Management: Cross-platform, modular concept with identical modules regardless of parameters.
- Asset Management: Integration into FieldCare and W@M.
Measuring System
A complete measuring system typically includes:
- Liquiline transmitter
- Sensors with Memosens technology
- Assemblies suited to the sensors
- Optional post retainer or railing
- Optional weather protection cover
Examples of measuring systems are provided for pH, ORP, conductivity, oxygen, nitrate, SAC, turbidity, interface measurement, and disinfection.
Equipment Architecture & Modules
The transmitter architecture is modular, allowing for flexibility in configuration. Modules are assigned to slots in ascending order.
- Basic Module: Always present, occupies slots 0 and 1.
- Optional Modules: Fieldbus (e.g., 485DP, 485MB), Memosens input (2DS), Digital Input/Output (DIO), Analog Input (2AI), Analog Output (4AO, 2AO), Relay (AOR, 4R, 2R).
- Hardware Upgrades: Specific rules apply for upgrading, with limitations on the number and type of modules.
- Module Assignment: Modules are assigned sequentially. Modules with 4 ports are connected before those with 2 ports of the same type.
Communication Protocols
- HART
- PROFIBUS DP (Profile 3.02)
- Modbus TCP or RS485
- PROFINET
- EtherNet/IP
Only one fieldbus communication type can be active at a time.
Dependability & Reliability
- Memosens Technology: Enhances safety and reliability through non-contact digital signal transmission, watertight design, and lab calibration capability.
- Heartbeat Diagnostics: Provides graphical indicators for device and sensor health, along with maintenance or calibration timers.
- Heartbeat Monitoring: Transmits sensor data (hours of operation, temperature exposure, sterilizations, etc.) for predictive maintenance.
- Heartbeat Verification: Allows for process verification without interruption.
- Sensor Check System (SCS): Monitors pH glass impedance for glass breakage or sensor issues.
- Process Check System (PCS): Checks for stagnation in the measuring signal.
- Self-monitoring: Includes overcurrent detection for current inputs, board voltage monitoring, and board temperature measurement.
- USP and EP Compliance: Implemented limit functions for conductivity measurements in pharmaceutical water (WFI, HPW, PW).
- ChemocleanPlus: Freely programmable sequence control for automatic sensor cleaning.
Ease of Maintenance
- Modular Design: Facilitates easy adaptation, retrofitting of extension modules, and upgrades.
- Data Logger Function: Stores various logbooks (measured values, calibration, hardware, version, operation, diagnostics) with adjustable scan times and large entry capacities.
- SD Card: Enables software updates, data storage, configuration transfer, and screenshot saving.
- External Signals: Digital inputs and outputs can be used for device control, measuring range switching, triggering cleaning, and more.
- FieldCare & Field Data Manager: Software for configuration, asset management, and data visualization.
- Virtual Process Values: Up to 8 calculated "virtual" process values can be created using mathematical functions.
- Concentration Tables: Factory-set and user-defined tables are available for converting inductive conductivity measurements to substance concentrations.
Safety Features
- Real-time Clock: Buffered by a battery for accurate time-stamping.
- Data Security: Settings and logbooks are stored in non-volatile memory.
- Measuring Range Switching: Can be used for CIP processes and phase separation monitoring.
- Measured Value Compensation: For oxygen and conductivity, with options for pressure, temperature, or external sensor inputs.
- Password Protection: For local and remote operation.
- Process Safety: Two independent PID controllers for one- or two-sided control.
- IT Security: Built-in mechanisms to protect against inadvertent setting changes.
Input Specifications
- Measured Variables: Refer to connected sensor documentation.
- Measuring Ranges: Refer to connected sensor documentation.
- Types of Input:
- Digital sensor inputs (Memosens protocol)
- Analog current inputs (optional, 0/4 to 20 mA, passive)
- Digital inputs (optional, 0 to 30 V)
- Intrinsically safe digital sensor inputs (Memosens protocol, Ex approval)
- Input Signal: Max. 8 binary sensor signals (or 6 with 2DS Ex-i module), optional 2 x 0/4 to 20 mA, 0 to 30 V.
- Cable Specification: Memosens data cable CYK10 or sensor fixed cable. Max. 100 m length.
- Digital Inputs (Passive): Span High (11 to 30 V DC), Low (0 to 5 V DC).
- Current Inputs (Passive): Span > 0 to 20 mA, linear characteristic.
Output Specifications
- Output Signal: 2, 4, 6, or 8 x 0/4 to 20 mA (active, galvanically isolated).
- HART Communication: Optional, via current output 1:1.
- PROFIBUS DP/RS485: EIA/TIA-485, multiple data transmission rates.
- Modbus RS485: EIA/TIA-485, multiple baud rates.
- Ethernet and Modbus TCP: IEEE 802.3, 10/100 MBd.
- Ethernet/IP: IEEE 802.3, 10/100 MBd.
- PROFINET: IEEE 802.3, 100 MBd.
- Signal on Alarm: Adjustable as per NAMUR Recommendation NE 43.
- Load (Current Outputs): Max. 500 Ω.
- Digital Outputs (Passive): Open collector, max. 30 V, 15 mA.
- Auxiliary Voltage: Unregulated, 24 V DC, max. 50 mA.
Environmental Conditions
- Ambient Temperature: See official PDF for exact tabulated values.
- Storage Temperature: See official PDF for exact tabulated values.
- Relative Humidity: See official PDF for exact tabulated values.
- Degree of Protection: See official PDF for exact tabulated values.
- Vibration Resistance: See official PDF for exact tabulated values.
- Electromagnetic Compatibility: See official PDF for exact tabulated values.
Mechanical Construction
- Dimensions: See official PDF for exact tabulated values.
- Weight: See official PDF for exact tabulated values.
- Materials: See official PDF for exact tabulated values.
Disclaimer: This summary is based on extracted text and may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.