Datasheet summary
Liquiline Compact CM82
Engineering summary from PDF text extraction for Liquiline Compact CM82. Verify every value with the OEM datasheet.
Summary
Product identification
- Product Name: Liquiline Compact CM82
- Product Type: Configurable multi-parameter transmitter for Memosens sensors
- Document: TI01397C/07/EN/03.22-00
Application
The CM82 transmitter is designed for monitoring and controlling industrial and environmental processes. It supports Memosens sensors for:
- pH
- ORP
- pH/ORP combined sensors
- Contacting conductivity
- Oxygen
Key Features and Benefits
- Space-saving: Two-wire device that fits into an assembly, requiring no separate power supply.
- Memosens Technology: Ensures safe, reliable, and digital signal transmission with features like galvanic isolation, watertight connections, and lab calibration capability.
- Communication:
- 4 to 20 mA output
- HART
- Bluetooth® LE interface (optional) for commissioning, maintenance, and remote operation via tablet/smartphone using the SmartBlue app.
- Operation: Standardized concept across the Liquiline platform.
- Reliability: Predictive maintenance through recording of sensor data (operating hours, temperature, sterilizations, sensor condition).
- Durability: Suitable for various environmental conditions including dust, steam, rain, snow, heat, and cold.
- USP/EP Compliance: Supports measurements for "Water for Injection" (WFI), "Highly Purified Water" (HPW), and "Purified Water" (PW) with alarm functions.
Communication and Data Processing
- Protocols:
- 4 to 20 mA
- Fieldbus HART
- Bluetooth® LE wireless technology (optional)
- Full device configuration is possible via Fieldbus and Bluetooth.
Input
- Measured Variable: Digital Memosens sensors for pH, ORP, pH/ORP combined, Conductive conductivity, Dissolved oxygen.
- Input Type: Digital sensor inputs for Memosens-sensors.
- Measuring Range: Refer to the documentation of the connected sensor.
Output
- Output Signal: 4 to 20 mA / HART, galvanically isolated from sensor circuits.
- Linearization: Linear.
- Transmission Behavior: Linear.
Power Supply
- Supply Voltage:
- 12.6 to 30 VDC (when failure current setting > 20 mA)
- 14 to 30 VDC (when failure current setting < 4 mA)
Performance Characteristics
- Resolution (Current output): < 5 µA
- Repeatability: Refer to the documentation of the connected sensor.
- Response Time (Current output): t90 = max. 500 ms for an increase from 0 to 20 mA.
- Tolerance (Current output at 25 °C):
- < ±20 µA (if current value = 4 mA)
- < ±50 µA (for current values 4 to 20 mA)
- Additional tolerance: < 1.5 µA/K
Environment
- Ambient Temperature Range: –20 to 85 °C (–4 to 185 °F)
- Storage Temperature: -40 to +85 °C (-40 to 185 °F)
- Relative Humidity: 5 to 95 %
- Degree of Protection: IP 67, IP 68, NEMA Type 6
- Electromagnetic Compatibility (EMC): EN 61326-1, EN 61326-2-3, EN 301489-1, EN 301489-17, NAMUR NE 21
- Electrical Safety: EN 61010-1
- Operating Height: < 2000 m (< 6562 ft) above MSL
- Pollution Degree: Complete device: Level 4; Internal: Level 2
Mechanical Construction
- Dimensions: See drawing in PDF.
- Materials:
- Housing, cover: Peek 151
- Strain relief: EPDM (peroxide crosslinked)
- Axial ring: Peek 450 G
- Optical waveguide: PC transparent
- Impact Loads: 1 J (IK06) as per EN 61010-1.
- Weight:
- Approx. 42 g (1.5 oz) without cable
- Approx. 190 g (7 oz) with 3 m cable
- Approx. 380 g (13 oz) with 7 m cable
- Approx. 760 g (27 oz) with 15 m cable
- Approx. 48 g (2 oz) per additional 1 m cable
Operability
- Operating Concept: Bluetooth® LE wireless technology and HART.
- Software: SmartBlue app (Android and iOS) for operation and commissioning.
System Design
A complete measuring system includes:
- Liquiline compact transmitter
- Sensors with Memosens technology
- Assemblies suited to the sensors
Accessories
A variety of Memosens sensors for pH, ORP, pH/ORP combined, conductivity, and oxygen are available. Software like Memobase Plus and DeviceCare, along with accessories like activation codes and junction boxes, are also listed.
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.