Liquiline System CA80HA

Engineering summary from PDF text extraction for Liquiline System CA80HA. Verify every value with the OEM datasheet.

Summary

Product identification

The Liquiline System CA80HA is a wet-chemical analyzer designed for the near-continuous determination of total hardness concentration in liquid media. It utilizes a colorimetric measuring principle.

Application

The analyzer is suitable for:

  • Optimization of reverse osmosis systems and ion exchangers.
  • Classification of drinking water hardness levels.
  • Ensuring process water quality in production plants.

Measuring principle

The Liquiline System CA80HA employs a colorimetric method. A reagent is added to the sample, causing a color change proportional to the total hardness. A multispectral photometer measures the light absorption at a specific wavelength (568 nm) to determine the concentration. A reference measurement is performed to compensate for interference.

Key Features and Benefits

  • Dual-channel capability: Supports up to two measuring channels.
  • Memosens Technology: Digital, non-contact signal transmission for enhanced safety and reliability. Allows for sensor calibration in a lab.
  • Expandable: Can be upgraded to a measuring station by connecting up to 4 Memosens sensors.
  • Cooled Version: Available for extended reagent life.
  • Digital Fieldbuses: Supports PROFINET, PROFIBUS DP, Modbus TCP, Modbus RS485, and Ethernet/IP.
  • Web Server: For remote configuration and access.
  • Tool-free Maintenance: Designed for simple and efficient upkeep.
  • Data Logging: Integrated ring or stack memories for recording measured values, events, and analyzer data.
  • Mathematical Functions: Ability to calculate up to 6 virtual process values.

Measuring System Components

A complete measuring system typically includes:

  • Liquiline System CA80HA Analyzer.
  • Integrated cooling module (optional).
  • Reagents, cleaner, and standard solutions (ordered separately).
  • Optional sample conditioning units (e.g., Liquiline System CAT810, CAT820, CAT860).

Sample Conditioning Options

  • Liquiline System CAT810 (Microfiltration): Pressure pipe sampling, 50 µm sieve filter, backflushing.
  • Liquiline System CAT820 (Membrane Filtration): Ceramic membrane filter (0.1 µm or 0.4 µm pore size), Memosens communication, backflushing.
  • Liquiline System CAT860 (Membrane Filtration): Ceramic membrane filter candle (0.1 µm or 0.4 µm pore size), automatic backflush with cleaning solution and compressed air.

Performance Characteristics

  • Measuring Range: 0 to 80 mg/l (ppm) CaCO₃.
    • With optional dilution function, ranges up to 1600 mg/l (ppm) CaCO₃ are configurable.
  • Maximum Measured Error:
    • 0 to 15 mg/l (ppm): ± 0.5 mg/l (ppm) CaCO₃.
    • 15 mg/l (ppm): ± 2.4 mg/l (ppm) CaCO₃.

    • With dilution factor 5: an additional ± 2.0 % of end of measuring range.
  • Repeatability: ± 0.3 mg/l (ppm).
    • With dilution factor 5: an additional ± 1.5 % of end of measuring range.
  • Measuring Interval: Continuous (approx. 7 min), adjustable from 10 min to 24 h.

Input and Output

  • Measuring Channels: 1 or 2 (analyzer main parameter).
  • Sensor Inputs: Up to 4 digital sensor inputs for Memosens protocol (optional).
  • Analog Inputs: 2 x 0/4 to 20 mA (optional), passive.
  • Analog Outputs: 2, 4, or 6 x 0/4 to 20 mA, active (depending on version).
  • Relay Outputs: 1 alarm relay standard, optional 2 or 4 additional relays.
  • Digital Inputs/Outputs: Optional module available.
  • Communication: PROFIBUS DP, Modbus TCP/RS485, PROFINET, EtherNet/IP.

Electrical Specifications

  • Supply Voltage: 100 to 120 V AC / 200 to 240 V AC or 24 V DC (not for "Outdoor" version). Frequency: 50 or 60 Hz.
  • Power Consumption: 130 VA (standard), up to 1450 VA (with cooling system and hose heater), max. 105 W (24-V version).

Mechanical Construction

  • Dimensions: Vary depending on the version (closed, open, or with base). See figures in the datasheet.
  • Weight: Cabinet version: 42 kg; Open installation: 34 kg; Analyzer stand: 75 kg.
  • Materials: Parts in contact with the medium include PP, TPE, FKM, EPDM, and FFKM. Exterior parts are typically ASA + PC or PP.
  • Process Connection: Sample inlet: Plug-in connector (OD 4 mm) or hose barb (ID 1.6 mm). Dilution water: Hose barb (ID 3.2 mm). Outlet: Hose barb (ID 13 mm).

Environmental Conditions

  • Ambient Temperature Range: +5 to +40 °C (41 to 104 °F).
  • Storage Temperature: –20 to 60 °C (–4 to 140 °F).
  • Relative Humidity: 10 to 95 %, non-condensing.
  • Degree of Protection: IP55 (cabinet, analyzer stand).
  • Electromagnetic Compatibility: As per EN 61326-1, class A.
  • Electrical Safety: According to EN/IEC 61010-1, Class I equipment, overvoltage category II.
  • Pollution Degree: 2.

Process Conditions

  • Sample Temperature: 4 to 40 °C (39 to 104 °F).
  • Consistency of the Sample: Low solids content (turbidity < 50 NTU), aqueous, homogenized.
  • Sample Supply: Unpressurized.