Datasheet summary
Liquiport CSP44
Engineering summary from PDF text extraction for Liquiport CSP44. Verify every value with the OEM datasheet.
Summary
Product identification
The Liquiport 2010 CSP44 is an automatic sampler for liquid media with an integrated multi-parameter controller. It features two measuring channels and optional digital Memosens technology.
Applications
- Communal and industrial wastewater treatment plants
- Self-monitoring
- Process monitoring
- Monitoring of indirect dischargers
- Monitoring of canal networks
- Authorities and water management offices (water pollution control, water quality, monitoring of dischargers)
- Laboratories and hydrological institutes
Function and system design
A complete sampling unit comprises:
- Controller with display, soft keys, and navigator
- Vacuum or peristaltic pump for sampling
- PE or glass sample bottles for sample preservation
- Optional sampling chamber temperature regulator
- Suction line with suction head
The device utilizes a peristaltic pump for sampling, which operates in three steps: Rinse, Intake, and Drain. This system allows for multiple rinses of the suction line before taking a sample. The peristaltic pump uses rollers to deform a hose, creating suction. A patented medium detection system based on a pressure sensor identifies when the sample is drawn. The self-learning software automatically calculates the sample volume and adjusts for suction height and line length. An optional safety switch can immediately shut off the pump when opened.
Sample distribution
The Liquiport 2010 CSP44 offers flexible sample distribution. Users can configure individual bottles and bottle groups for main, switchover, and event programs. A distribution arm transfers the sample liquid into bottles. Options include a 20-liter composite container made of PE and various other bottle distributions that can be easily replaced.
Sample preservation
Sample bottles are stored in a sample compartment with a seamless plastic dish for easy cleaning. Removable parts that contact the medium can be cleaned easily without tools.
Sampling control
The sampler supports various sampling control methods:
- Time-proportional sampling (CTCV): A constant sample volume is taken at regular intervals.
- Volume-proportional sampling (VTCV): A constant sample volume is taken at variable intervals based on inflow volume. An optional time override can interrupt long, flow-controlled intervals with a time-controlled sample if flow is low.
- Flow-proportional sampling (CTVV): A variable sample volume (dependent on flow rate) is taken at regular intervals. This is only available with the peristaltic pump version.
- Event-controlled sampling: Sampling is triggered by an event, such as a pH limit value. Sampling can be time-paced, volume-paced, flow-paced, or single samples can be taken.
Single and multiple samples can be grouped within a program. The software allows for interval sampling, switchover, and event functions, with up to 24 subprograms active simultaneously. A sampling table enables programming of bottle assignment, time intervals, and sample volumes. External control signals can be connected via 2 analog inputs and 2 binary inputs in the standard version.
Intake speed with different suction lines
Intake speed varies with suction line diameter. For a 10 mm (3/8") ID peristaltic pump:
- Intake speed as per Ö 5893, US EPA: approx. 0.6 m/s to 1.0 m/s for suction heights of 3.3 m to 6.6 m.
- Intake speed as per EN 25667, ISO 5667: approx. 0.5 m/s to 1.2 m/s for suction heights of 2.0 m to 9.9 m.
Sampler housing
The housing material should be considered for outdoor installations. Plastic polystyrene VO may discolor in direct sunlight. Plastic ASA+PC V0 is recommended for outdoor installations without a sun guard. Discoloration does not affect functionality.
Dependability
Reliability
Memosens technology:
- Non-contact, digital signal transmission for galvanic isolation.
- No contact corrosion.
- Watertight design.
- Allows for laboratory sensor calibration, increasing measured value availability.
- Enables predictive maintenance through recording of sensor data (total hours of operation, hours at extreme values, hours at high temperatures, number of steam sterilizations, sensor condition).
Sensor check system (SCS): Monitors the high impedance of pH glass, triggering an alarm if minimum or maximum impedance values are exceeded (e.g., due to glass breakage, dry sensor, or worn membrane).
Process check system (PCS): Checks for stagnation in the measuring signal, triggering an alarm if the signal does not change over a period. Causes can include a fouled sensor, sensor outside the medium, or a process error.
Sensor condition check (SCC): Monitors electrode condition and aging, indicating "SCC electrode condition bad" or "SCC electrode condition OK."
Maintainability
The sampler features a modular design for easy adaptation and retrofitting of extension modules.
Memory:
- Integrated ring or stack memories for recording analog values, events (e.g., power failure), and sample statistics.
- Program memory: Max. 100 programs.
- Data logbooks: Up to 8 logbooks, each with up to 150,000 entries. Scan time adjustable from 1 to 3600 s. Can display graphic load curves or numerical lists.
- Calibration logbook: Max. 75 entries.
- Hardware logbook: Records hardware configuration and modifications, max. 125 entries.
- Version logbook: Records software updates, max. 50 entries.
- Operations logbook: Max. 250 entries.
- Diagnostic logbook: Max. 250 entries.
Mathematical functions (virtual process values): Up to 6 virtual process values can be calculated using mathematical functions (e.g., pH from conductivity, difference between values, differential conductivity, degassed conductivity, redundancy monitoring, rH calculation). These virtual values can be output, used as control variables, assigned to limit contactors, trigger cleaning, or displayed.
FieldCare and Field Data Manager: Software for configuration, asset management, and data visualization. Logbooks can be downloaded in CSV or binary format. Field Data Manager uses an SQL database for storing and analyzing measuring, calibration, and configuration data.
Safety
- Real-time clock: Backed up by a button cell to maintain correct time and date for logbook timestamps.
- Data security: Settings and logbooks are stored in non-volatile memory.
Input
- Up to two analog inputs.
- Up to two binary inputs.
- 1 to 2 digital inputs for sensors with Memosens protocol (optional).
Temperature inputs
- Measuring range: -30 to 70 °C (-20 to 160 °F)
- Type of input: Pt1000
- Accuracy: ± 0.5 K
Binary input, passive
- Span: 12 to 30 V, galvanically isolated
- Minimum pulse width: 100 ms
- Accuracy: ± 0.5 K
Analog input, passive/active
- Span: 0/4 to 20 mA, galvanically isolated
- Accuracy: ±0.5 % of measuring range
Output optional
Communication
- 1 service interface, accessible via front panel connection (optional).
- Commubox FXA291 (accessory) required for PC communication.
Power supply
Electrical connection
- Supply voltage: Internal 24 V DC, 7.2 Ah lead-acid battery.
- Field-suitable: IP 67.
- Indoor use: 100 to 240 V AC charger (charge current 2.0 A), also suitable for mains operation.
- Charger specification: Max. output current 2 A, Max. output voltage 29.5 V, Double/reinforced insulation, Constant current, CSA or UL recognized.
Power consumption
- Max. 60 W (only when using manufacturer-indicated battery chargers).
Capacity of battery
- 42 hours for 168 samples (at 15 min interval, 100 ml volume, 4 m suction height).
- Standby capacity: 144 hours (data applicable if analog input is switched off and for devices without Memosens input).
Fuses
- Input fuse: T3.15A
- Electronics fuse: T4.0A
Performance characteristics
Sampling methods
- Vacuum pump/peristaltic pump/sampling assembly: Event sampling, single and multiple samples, sampling table.
- Peristaltic pump: Time-paced, in proportion to volume, flow proportional sampling/time override (CTVV).
Dosing volume
- Peristaltic pump: 10 to 10000 ml (0.3 to 340 fl.oz.).
- Dosing accuracy and repeatability for sample volumes < 20 ml may vary.
Dosing accuracy
- Peristaltic pump: ± 5 ml (0.17 fl.oz.) or 5 % of the set volume.
Repeatability
- 5 %
Intake speed
-
0.5 m/s (> 1.6 ft/s) for ≤ 13 mm (1/2") ID, as per EN 25667, ISO 5667, CEN 16479-1.
-
0.6 m/s (> 1.9 ft/s) for 10 mm (3/8") ID, in accordance with Ö 5893; US EPA.
Suction height
- Peristaltic pump: Max. 8 m (26 ft).
Hose length
- Max. 30 m (98 ft).
Installation
Mounting conditions
The suction line should be routed with a downward slope. Avoid siphon formation. The device should be erected on a level surface, securely fastened, and protected against additional heating, mechanical vibrations, and strong magnetic fields.
Environment
- Ambient temperature range: 0 to 40 °C (32 to 104 °F). Do not install in high temperatures or direct sunlight.
- Storage temperature: -20 to 60 °C (-4 to 140 °F).
- Degree of protection: Sample compartment: IP 54, Sampler with cover closed: IP 54, Controller: IP 65.
- Electromagnetic compatibility: Interference emission and immunity as per EN 61326-1:2006, class A for industry.
- Electrical safety: In accordance with EN 61010-1, protection class I, environment ≤ 2000 m (6500 ft) above MSL. Pollution degree 2.
- Relative humidity: 10 to 95%, not condensing.
Process
- Process temperature: 2 to 50 °C (36 to 122 °F).
- Process characteristics: Sample media must be free of abrasive substances. Ensure material compatibility of wetted parts.
- Process pressure: Unpressurized, open channel.
- Process connection:
- Vacuum pump: Suction line ID 10 mm (3/8"), 13 mm (1/2"), 16 mm (5/8") or 19 mm (3/4").
- Peristaltic pump: Intake hose ID 10 mm (3/8").
Mechanical construction
Dimensions
See accompanying diagram for dimensions.
Weight
- Empty weight: 15 kg (33 lbs).
- Overall weight with battery and 24 x 1 l bottles: 19 kg (42 lbs).
- Upper compartment with battery: 10 kg (22 lbs).
- Lower compartment with 24 x 1 l bottles: 9 kg (20 lbs).
- With full bottles, the sampler weighs over 25 kg (55 lbs). Transport with a second person is recommended to comply with ISO 11228-1.
Materials
- Plastic polystyrene VO can discolor in direct sunlight; Plastic ASA+PC V0 is recommended for outdoor use without a cover. Discoloration does not affect functionality.
Wetted parts:
- Peristaltic pump: Pump tubing (Silicone), Distribution arm (Plastic PP), Distribution arm cover (Plastic PE), Distribution plate (Plastic PS), Composite container/bottles (Plastic PE, glass), Intake hose (Plastic PVC, EPDM).
- Process seal: Viton recommended for standard applications with watery samples.
- Housing: Plastic PE.
- Bottles: Plastic PE, glass (depending on version).
- Sensor housing: Plastic PP.
Operability
Operating concept
Intuitive operation using a navigator and soft keys for fast configuration and diagnosis. Plain-text display available in all ordered languages.
Display
- Graphic display: 240 x 160 pixel resolution, backlight with switch-off function, red background for alarms, transflective display for contrast. User-definable measuring menus.
- Local operation: LCD, illuminated (red background for errors), 160 x 240 pixels, 4 operating keys and navigator.
Communication
- 1 service interface.
- Commubox FXA291 (accessory) required for PC communication.
Software
- Field Data Manager: Windows-based software for reading out internal memory data and analyzing reports.
- FieldCare: For device settings saved in a database and configuration.
Certificates and approvals
- CE mark: Complies with EU directives.
- MCERTS: Complies with MCERTS Performance Standards for Water Monitoring Equipment Part 1, Version 2.1. Certificate no.: Sira MC100176/02.
- cCSAus General purpose: Meets requirements for laboratory equipment, electrical, certified to US standards for indoor use. Certificate no.: 2318018.
Ordering information
Detailed ordering information and product configuration are available via the product page: www.endress.com/CSP44.
Scope of delivery
Includes the Liquiport 2010 CSP44 with ordered bottle configuration and optional hardware, a print version of Brief Operating Instructions, and optional accessories.
Disclaimer: Extraction may miss figures, footnotes, or revisions; contractual data must match the OEM PDF revision used on the project.