Datasheet summary
Liquisys M COM223-253
Engineering summary from PDF text extraction for Liquisys M COM223-253. Verify every value with the OEM datasheet.
Summary
Product identification
Product: Liquisys M COM223/253 Transmitter for oxygen sensors
Applications:
- Wastewater treatment plants and wastewater treatment
- Water treatment and drinking water monitoring
- Surface water: rivers, lakes, sea
- Fish farming
- Boiler feedwater (trace measurement)
Benefits:
- Field or panel-mounted housing
- Universal application
- Easy to use with simple menu structure and calibration options
- Manual contact control and user-defined alarm configuration
Optional Extensions:
- 2 or 4 contacts for limit contacts, P(ID) controller, or timer functions (e.g., rinse processes, Chemoclean).
- Plus package: Configurable current output characteristic, automatic cleaning start, process monitoring, sensor signal live check.
- HART or PROFIBUS-PA/-DP communication.
- Second current output for temperature, main measured value, or actuating variable.
- Current input for flow monitoring or feedforward control.
Measuring System Components
A complete measuring system includes:
- Transmitter: Liquisys M COM223 or COM253
- Oxygen sensor:
- COS41 for COM2x3-DS/DX
- COS61 for COM2x3-WS/WX
- Optional: Extension cable, junction box, weather protection cover.
Input
Measured Values:
- Oxygen
- Temperature
Measuring Ranges:
- Oxygen Concentration: 0 to 20 mg/l
- Saturation Index: 0 to 200 % SAT
- Partial Pressure: 0 to 400 hPa (0 to 6 psi)
- Temperature: -10 to 60 °C (can also be displayed in °F)
Signal Input:
- DS/DX version: 0 to 3000 nA
- WS/WX version: Digital communication or 0 to -7500 mV
Binary Inputs:
- Voltage: 10 to 50 V
- Current consumption: Max. 10 mA
Current Input:
- 4 to 20 mA, galvanically isolated
- Load: 260 Ω for 20 mA (voltage drop 5.2 V)
Output
Output Signal:
- 0/4 to 20 mA, galvanically isolated, active
- HART: Signal encoding FSK + 0.5 mA via current output, 1200 baud, galvanically isolated.
- PROFIBUS PA: Manchester Bus Powered (MBP), 31.25 kBit/s (voltage mode), galvanically isolated (IO modules).
- PROFIBUS DP: RS485, data rates up to 1.5 MBd, galvanically isolated (IO modules).
- Signal on alarm: 2.4 or 22 mA in event of error.
- Load: Max. 500 Ω
- Transmission range:
- Concentration: Δ 0.2 to Δ 20 mg/l
- Saturation index: Δ 2 to Δ 200 % SAT
- Partial pressure: Δ 4 to Δ 400 hPa
- Signal resolution: Max. 700 digits/mA
- Separation voltage: Max. 350 VRMS / 500 V DC
Auxiliary Voltage Output:
- Output voltage: 15 V ± 0.6 V
- Output current: Max. 10 mA
Contact Outputs:
- Switching current (ohmic load, cos φ = 1): Max. 2 A
- Switching current (inductive load, cos φ = 0.4): Max. 2 A
- Switching voltage: Max. 250 V AC, 30 V DC
- Switching power (ohmic load, cos φ = 1): Max. 500 VA AC, 60 W DC
- Switching power (inductive load, cos φ = 0.4): Max. 500 VA AC, 60 W DC
- Limit contactors: Pickup/dropout delay 0 to 2000 s
Controller
- Function: Pulse length/pulse frequency controller, continuous controller.
- Behavior: P, PI, PD, PID, basic load dosing.
- Control gain Kp: 0.01 to 20.00
- Integral action time Tn: 0.0 to 999.9 min
- Derivative action time Tv: 0.0 to 999.9 min
- Period length (pulse length controller): 0.5 to 999.9 s
- Frequency (pulse frequency controller): 60 to 180 min⁻¹
- Basic load: 0 to 40 % of max. actuating variable
Alarm
- Function: Latching/momentary contact.
- Alarm threshold adjustment range: O₂ / temperature: entire measuring range.
- Alarm delay: 0 to 2000 s
- Monitoring time for lower limit violation: 0 to 2000 min
- Monitoring time for upper limit violation: 0 to 2000 min
Protocol-Specific Data
HART:
- Manufacturer ID: 11h
- Device type: 0094h
- Transmitter-specific revision: 0001h
- HART version: 5.0
- HART load (communication resistor): 250 Ω
PROFIBUS PA:
- Manufacturer ID: 11h
- Device type: 1518h
- Device revision: 0001h
- Profile version: 2.0
PROFIBUS DP:
- Manufacturer ID: 11h
- Device type: 151Eh
- Profile version: 2.0
Power Supply
- Supply voltage:
- 100/115/230 V AC +10/-15 %, 48 to 62 Hz
- 24 V AC/DC +20/-15 %
- Power supply via fieldbus:
- HART: Not applicable (active current outputs).
- PROFIBUS PA: 9 V to 32 V, max. 35 V.
- PROFIBUS DP: 9 V to 32 V, max. 35 V.
- Power consumption: Max. 7.5 VA
- Mains fuse: Fine-wire fuse, semi-delay 250 V/3.15 A
Electrical
Cable Specifications:
- COS61 cable length: Max. 100 m (330 ft)
- COS41 cable length: Max. 50 m (160 ft)
Performance Characteristics
- Reference conditions: Temperature 25 °C (77 °F), Pressure 1013 hPa (15 psi), Air-saturated water.
- Measured value resolution:
- Oxygen: 0.01 mg/l / 0.1 % SAT / 1 hPa
- Temperature: 0.1 °C
- Maximum measured error:
- Display (Oxygen): Max. 0.5 % of measuring range
- Display (Temperature): Max. 1.0 % of measuring range
- Signal output (Oxygen): Max. 0.75 % of measuring range
- Signal output (Temperature): Max. 1.25 % of measuring range
- Repeatability: Max. 0.2 % of measuring range
- Slope adjustment:
- COS41: 75 to 140 %
- COS61: 75 to 140 %
Mechanical / Hydraulic
Dimensions:
- Panel-mounted device: Max. 0.7 kg (1.54 lbs.)
- Field device: Max. 2.3 kg (5.07 lbs.)
Materials:
- Panel-mounted device housing: Polycarbonate
- Field housing: ABS PC FR
- Front membrane: Polyester, UV-resistant
- Terminals: Max. 2.5 mm² (14 AWG) cable cross-section.
Environmental Limits:
- Ambient temperature range: -10 to +55 °C (+10 to +130 °F)
- Storage temperature: –25 to +65 °C (-10 to +150 °F)
- Degree of protection:
- Field device: IP 65 / NEMA 4X
- Panel-mounted device: IP 54 (front), IP 30 (housing)
- Relative humidity: 10 to 95%, non-condensing
- Degree of contamination: Suitable for pollution degree 2.
Dependability
Calibration:
- Amperometric sensors (COS41): One-point calibration in air, air-saturated water, or medium.
- Optical sensor (COS61): Calibrated on delivery, recalibration in air and at zero point if necessary.
Sensor Live Check (Plus package):
- Checks measuring signal for stagnation, triggering an alarm if no change occurs over a specified period.
Current Output Configuration (Plus package):
- Configurable via table for wide measuring ranges and high resolution (e.g., bilinear, quasi-logarithmic curves).
Automatic Pressure Compensation (DS/WS/WX versions):
- Accounts for atmospheric pressure variations affecting oxygen concentration.
Safety:
- Process Safety: Independently configurable fault-signaling contact and error current. Up to four contacts can be used as limit contacts, P(ID) controller, or cleaning functions. Direct manual operation of contacts is possible.
- Electrical Safety: As per EN/IEC 61010-1:2010, overvoltage category II for installations up to 2000 m (6500 ft) above MSL.
- Overvoltage protection: According to EN 61010-1.
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.