Memosens CPF82E

Engineering summary from PDF text extraction for Memosens CPF82E. Verify every value with the OEM datasheet.

Summary

Product identification

Product Name: Memosens CPF82E Product Type: ORP sensor Technology: Memosens 2.0

Application

The Memosens CPF82E is designed for various applications in mining operations, industrial water, and wastewater treatment, including:

  • Flotation
  • Leaching
  • Neutralization
  • Outlet monitoring
  • Inlet and outlet monitoring

Key Features and Benefits

  • Electrolyte Bridge: Features a proven KNO₃ electrolyte bridge for enhanced protection against electrode poisons such as S²⁻ or CN⁻ ions.
  • Installation: Equipped with threaded connections (NPT ¾") top and bottom for straightforward user installation.
  • Temperature Range: Suitable for measurements within a temperature range of 0 to 80 °C (32 to 176 °F).
  • Temperature Sensor: Includes an integrated NTC 30K temperature sensor.
  • Protection: Comes with a protection guard to prevent damage.
  • Memosens Technology Benefits:
    • Process Safety: Maximum safety through non-contact, inductive signal transmission.
    • Data Security: Secure digital data transmission.
    • Ease of Use: Sensor data (e.g., calibration data, operating hours) are saved in the sensor for easy handling and quick replacement.
    • Predictive Maintenance: Enables predictive maintenance by recording sensor load data.

Measuring Principle

  • ORP Measurement: Measures the oxidation-reduction potential (ORP), indicating the equilibrium state between oxidizing and reducing components in a medium.
  • Electrodes: Uses a platinum or gold electrode for ORP measurement, with an integrated Ag/AgCl reference system.

Measuring System Components

A complete measuring system comprises:

  • Sensor CPF82E
  • Transmitter (e.g., Liquiline CM44x/R or Liquiline M CM42)
  • Memosens data cable (e.g., CYK10)

Communication and Data Storage

  • Digital sensors with Memosens technology must be connected to a Memosens-compatible transmitter.
  • The sensor can store various data, including:
    • Manufacturing data (serial number, order code, date of manufacture)
    • Calibration data (date, offset, history)
    • Application data (temperature/ORP range, first commissioning date, operational hours)
  • This data can be accessed via transmitters like Liquiline CM42/CM44x or Memobase Plus CYZ71D.

Input

  • Measured Variables:
    • ORP: -1500 mV to +1500 mV
    • Temperature
  • Reference System: Double chamber reference system with 3 M KNO₃ gel and Ag/AgCl reference lead with 3 M KCl gel.

Environmental and Process Limits

  • Ambient Temperature Range: Storage temperature is 0 to 50 °C (32 to 122 °F). (Note: Do not use below 0 °C due to frost risk).
  • Degree of Protection: IP 68 (rated for 10 m water column, 25 °C, 45 days, 1 M KCl).
  • Electromagnetic Compatibility (EMC): Complies with EN 61326-1, EN 61326-2-3, and NAMUR NE21.
  • Process Temperature Range: 0 to 80 °C (32 to 176 °F).
  • Process Pressure Range: 0.8 to 11 bar (11.6 to 159.5 psi) absolute. (Caution: Avoid rapid heating of pressurized sensors under reduced pressure).
  • Minimum Conductivity: 50 μS/cm (at atmospheric pressure, without flow, minimized flow; pressure and temperature must remain constant).

Mechanical Construction

  • Dimensions: See the provided diagram for detailed dimensions. The sensor features an NPT ¾" thread.
  • Weight: 0.12 to 0.15 kg (0.26 to 0.33 lb), excluding cable.
  • Materials:
    • Housing, sensor shaft: PPS
    • ORP sensor: Platinum
    • Double chamber reference system: KNO₃ and KCl/AgCl
    • Plug-in head: Memosens plug-in head (pressure resistance 16 bar relative).
  • Process Connections: NPT ¾".

Certificates and Approvals

  • CE mark
  • TÜV certificate for Memosens plug-in head (pressure resistance 16 bar relative)
  • EAC conformity

Ordering Information

Refer to the product page (www.endress.com/cpf82e) for configuration and to obtain a complete order code.

Scope of Delivery

  • Sensor in the ordered version
  • Operating Instructions

Accessories

  • Assembly: Flexdip CYA112 (Immersion assembly)
  • Measuring Cable: Memosens data cable CYK10, Measuring cable CPK9
  • Buffer Solutions: ORP buffer solution CPY3