Product identification

  • Product name: Memosens CPL51E
  • Product type: pH sensor for laboratory measurements and random sampling in the field
  • Technology: Digital with Memosens 2.0 technology
  • Document revision: TI01672C/07/EN/01.20-00, 2022-01-03

Application

Measurements in drinking water, wastewater and process water.

Your benefits

  • Simple to use, extremely versatile
  • Physical protection of glass membrane
  • Minimum risk of contamination thanks to open aperture diaphragm
  • Fast response time even in cold, ion-weak water
  • Integrated temperature sensor for automatic temperature compensation
  • Suitable for use with Liquiline Mobile, Liquiline To Go and Memobase Plus

Other advantages of Memosens technology

  • Maximum analysis safety with non-contact, inductive signal transmission
  • Data security thanks to digital data transmission
  • Very easy to use as sensor data saved in the sensor

Function and system design

Measuring principle: pH measurement

The pH value is used as a unit of measurement for the acidity or alkalinity of a medium. The membrane glass of the electrode delivers an electrochemical potential that depends on the pH value of the medium. This potential is generated by the selective accumulation of H⁺ ions on the outer layer of the membrane. As a result, an electrochemical boundary layer with an electrical potential difference forms at this point. An integrated Ag/AgCl reference system serves as the required reference electrode. The measured voltage is converted to the corresponding pH value using the Nernst equation.

Measuring system

  • Transmitter CML18
  • Smartphone with Smartblue app (optional)
  • Memosens CPL51E

Communication and data processing

  • Always connect digital laboratory sensors with Memosens technology to a handheld device with Memosens technology, e.g. CML18.

Digital laboratory sensors can store measuring system data in the sensor, including:

  • Manufacturer data
  • Serial number
  • Order code
  • Date of manufacture
  • Calibration data
  • Calibration date
  • Number of calibrations
  • Serial number of the handheld device used to perform the last calibration or adjustment
  • Application data
  • Temperature application range
  • pH application range
  • Date of initial commissioning

Input

  • Measured variable: pH value, Temperature

Measuring range

  • pH value: 0 to 14 pH
  • Temperature: 0 to 80 °C (32 to 176 °F)

Performance characteristics

  • Reference system: Ag/AgCl lead, bridging electrolyte: gel KCl, 3M, AgCl-free

Environment

  • Ambient temperature range: Do not use the sensor at temperatures below 0 °C (32 °F) (Risk of damage from frost).
  • Storage temperature: 0 to 50 °C (32 to 122 °F), non-freezing
  • Degree of protection: IP 68 (10 m (33 ft) water column, 25 °C (77 °F), 45 days, 1 M KCl)
  • Electromagnetic compatibility (EMC): Interference emission and interference immunity as per EN 61326-1: 2013

Process

  • Process temperature range: 0 to 80 °C (32 to 176 °F)

Mechanical construction

  • Dimensions: Ø 11.9 (0.47) x 120 (4.7) mm (in)
  • Weight: 33 g (1.2 oz)
  • Materials:
    • Sensor shaft: PEEK
    • Metal lead: Ag/AgCl
    • Nameplate: Ceramic metal oxide
    • Junction: Open junction
    • Temperature sensor: NTC 30K
    • Plug-in head: Memosens laboratory plug-in head for digital, non-contact data transmission
  • Process connections: Pg 13.5

Accessories

  • Memosens data cable CYK10
  • Memosens laboratory cable CYK20
  • Liquiline Mobile CML18
  • Memobase Plus CYZ71D
  • Buffer solutions from Endress+Hauser - CPY20

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.