Datasheet summary
Memosens CPS72E
Engineering summary from PDF text extraction for Memosens CPS72E. Verify every value with the OEM datasheet.
Summary
Product Identification
- Product Name: Memosens CPS72E
- Product Type: ORP sensor for chemical process applications
- Technology: Digital with Memosens 2.0 technology
Application
Process technology and monitoring of processes with:
- Rapidly changing ORP values
- High proportion of electrode poisons, such as H₂S
Approvals for use in hazardous areas (Zone 0, 1, and 2):
- ATEX
- IECEx
- CSA C/US
- NEPSI
- Japan Ex
- INMETRO
Key Features and Benefits
- Poison-resistant reference with improved ion trap for long service life.
- Bridging electrolyte free of silver ions and acrylamide-free.
- Integrated NTC 30K temperature sensor for effective temperature compensation.
- Suitable for CIP/SIP cleaning and autoclavable.
- Maximum process safety via non-contact, inductive signal transmission.
- Data security through digital data transmission.
- Easy to use with sensor data saved in the sensor.
- Predictive maintenance possible by recording sensor load data.
Measuring Principle
- Measured Variable: ORP (Oxidation-Reduction Potential)
- ORP Measurement: Measures the state of equilibria between oxidizing and reducing components. Uses a platinum or gold electrode with an integrated Ag/AgCl reference system.
- Temperature Measurement: Integrated NTC 30K temperature sensor.
Measuring System Components
A complete measuring system comprises:
- ORP sensor CPS72E
- Memosens data cable (CYK10 or CYK20)
- Transmitter (e.g., Liquiline CM42, CM44x)
- Assembly (e.g., immersion, flow, retractable)
- Optional: Automatic cleaning and calibration system (e.g., Liquiline Control CDC90)
Communication and Data Processing
- Memosens sensors must be connected to a Memosens transmitter.
- Digital sensors store data including: Manufacturer data, serial number, order code, date of manufacture, calibration data, operating data, and sensor load data.
- Stored data can be displayed with Liquiline CM42, CM44x, and Memobase Plus CYZ71D.
- Calibration can be performed independently of the measuring point.
Performance Characteristics
- Reference System: Ag/AgCl reference lead, bridging electrolyte: gel KCl, 3M, AgCl-free, with ion trap.
- Measuring Range:
- ORP: –1500 to 1500 mV
- Temperature: See Process temperature range below.
Installation
- Orientation:
- Must be installed at an angle of at least 15° from the horizontal.
- Upside-down installation is not permitted.
- Installation Instructions:
- Ensure assembly thread, O-rings, and sealing surface are clean and undamaged.
- Tighten sensor by hand to a torque of 3 Nm (2.21 lbf ft) when installing in Endress+Hauser assemblies.
Environmental and Process Limits
- Ambient Temperature Range:
- Storage: 0 to 50 °C (32 to 122 °F)
- Operating: Not specified in extract, but frost risk below 0 °C.
- Degree of Protection: IP 68 (10 m (33 ft) water column, 25 °C (77 °F), 45 days, 1 M KCl)
- Electromagnetic Compatibility (EMC): EN 61326-1:2013, EN 61326-2-3:2013, NAMUR NE21:2017.
- Process Temperature Range: 0 to 140 °C (32 to 284 °F)
- Process Pressure Range: 0.8 to 14 bar (11.6 to 203 psi) (absolute)
- Conductivity: ≥ 10 μS/cm (at atmospheric pressure, without flow)
Mechanical Construction
- Sensor Shaft Material: Glass
- ORP Measuring Element: Platinum
- Reference Lead Material: Ag/AgCl
- Junction Material: Ceramic, zirconium dioxide
- O-ring Material: FKM
- Process Coupling Material: PPS fiber-glass reinforced
- Plug-in Head: Memosens plug-in head, pressure resistance 16 bar (232 psi) (relative)
- Process Connections: Pg 13.5
- Installed Lengths: 120 mm (4.72 in), 225 mm (8.86 in), 360 mm (14.17 in), 425 mm (16.73 in)
- Weights: Corresponding to installed lengths: 40 g (1.4 oz), 60 g (2.1 oz), 90 g (3.2 oz), 100 g (3.5 oz).
Certificates and Approvals
- CE Marking: Complies with EU directives.
- Ex Approvals:
- ATEX: II 1G Ex ia IIC T3/T4/T6 Ga
- IECEx: Ex ia IIC T3/T4/T6 Ga
- NEPSI: Ex ia IIC T3/T4/T6 Ga
- CSA C/US: IS Cl. I Div 1, GP A-D Ex ia IIC T3/T4/T6; IS Cl. I Zone 0, AEx ia IIC T3/T4/T6
- Japan Ex: Ex ia IIC T3/T4/T6 Ga
- INMETRO: Ex ia IIC T3/T4/T6 Ga
- Other: EAC
Accessories
A variety of assemblies (Unifit, Cleanfit, Dipfit, Flowfit), buffer solutions (ORP buffer solution CPY3), and Memosens data cables (CYK10, CYK20) are available.
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.