Summary

Product identification

  • Product Name: Memosens CPS96E
  • Description: pH/ORP sensor for heavily polluted media and suspended solids
  • Technology: Memosens 2.0

Application

  • Chemical processes
  • Pulp and paper industry
  • Flue gas cleaning
  • Contaminated media including solids, precipitation reactions, and emulsions.
  • Suitable for hazardous areas (Zone 0, Zone 1, and Zone 2) with ATEX, IECEx, CSA C/US, NEPSI, Japan Ex, and INMETRO approvals.

Operating limits

  • Process Temperature Range: 0 to 110 °C (32 to 230 °F)
  • Process Pressure Range: 0.8 to 14 bar (11.6 to 203 psi) absolute
  • Conductivity: > 500 μS/cm (with minimized flow, constant pressure and temperature)

Feed water

  • Minimum Conductivity: > 500 μS/cm

Product water

  • Not applicable.

Measuring principle

The CPS96E sensor measures:

  • pH: Utilizes a membrane glass electrode that generates a potential dependent on the medium's pH value, with an integrated Ag/AgCl reference system. The voltage is converted to pH using the Nernst equation.
  • ORP (Oxidation-Reduction Potential): Measured using a platinum electrode, with an integrated Ag/AgCl reference system.
  • rH: Calculated by simultaneously measuring pH and ORP. The rH value indicates the oxidizing or reducing power of a solution on a scale from 0 to 42.

Electrical

  • Temperature Sensor: Integrated NTC 30K for temperature compensation.
  • Communication: Digital sensors with Memosens technology require a Memosens transmitter for data transmission. Analog transmitters are not compatible.

Mechanical / hydraulic

  • Reference System: Ag/AgCl reference lead with a stabilized bridging electrolyte gel containing an ion trap.
  • Electrode Design: Features an open aperture for use in processes with solids.
  • Glass Breakage and Blockage Detection: Monitors the resistance of the glass membrane and reference impedance.
  • Installation Orientation: Must be installed at an angle of at least 15° from the horizontal to prevent air bubbles.
  • Weight: Varies by installed length, from 40 g to 100 g.
  • Materials:
    • Sensor Shaft: Glass
    • pH Membrane Glass: Type B
    • Metal Lead: Ag/AgCl
    • O-ring: FKM
    • ORP Measuring Element: Platinum
    • Process Coupling: PPS fiber-glass reinforced
    • Nameplate: Ceramic metal oxide
    • Temperature Sensor: NTC 30K
    • Plug-in Head: Memosens plug-in head (Pressure resistance: 16 bar (232 psi) relative)
  • Process Connections: Pg 13.5
  • Degree of Protection: IP 68 (rated for 10 m (33 ft) water column, 25 °C (77 °F), 45 days, 1 M KCl)
  • Electromagnetic Compatibility (EMC): Complies with EN 61326-1, EN 61326-2-3, and NAMUR NE21.

Certificates and approvals

  • CE mark
  • Ex approvals: ATEX, IECEx, NEPSI, CSA C/US, Japan Ex, INMETRO (specific classifications provided in the extract).
  • TÜV certificate for Memosens plug-in head.
  • EAC conformity mark.

Disclaimer