Back to Endress + Hauser Liquid analysis
Endress+Hauser logo

Datasheet summary

DipFit W CPA530

Engineering summary from PDF text extraction for DipFit W CPA530. Verify every value with the OEM datasheet.

Summary

Product identification

  • Manufacturer: Endress+Hauser
  • Designation: DipFit W CPA 530
  • Type: Suspended assembly with bayonet lock-mounted electrode holder

Areas of application

  • Water and waste water treatment systems
  • In conduits, ducts or tall tanks
  • Wherever clearance precludes long, rigid assemblies
  • Wherever the assembly is not directly accessible

Operating limits

  • Operating pressure and temperature:
    • max. 3 bar (at 20 °C)
    • with oval flange and mounting plate: unpressurized up to +50 °C
  • Maximum immersion depth: 10 m

Feed water

  • Materials in contact with medium:
    • Immersions tube (bayonet with holder): PVC, titanium
    • Electrode holder: PPS
    • Flange, oval plate: PVC, UP-GF
    • Protective hose: PVC
    • O-rings: EPDM, Viton
    • Potential matching pin: Hastelloy C4

Product water

Not specified in the extract.

Electrical

  • Ingress protection: IP 68
  • Cable features:
    • Flange with pressure-water-tight cable gland
    • PVC hose provides additional protection for measuring cable
    • Electrode can be replaced without detaching the pressure-tight cable gland

Mechanical / hydraulic

  • Mounting method: Bayonet lock
  • Electrode holder: Suitable for standard combination electrodes with Pg 13.5 thread
  • Available mounting versions:
    • DN 50 flange, PN 10
    • Union nut and DN 50 flange
    • Oval flange and mounting plate
  • Hose length: Up to 10 m
  • Required installation diameter: DN 50
  • Weight: approx. 2 to 2.5 kg

Accessories

  • Electrodes:
    • pH combination electrode: measuring range pH 1 to pH 12, up to 6 bar, 0 ... +80 °C (order-no.: CPS 11-1 AA 2 GSA)
    • pH combination electrode with integrated Pt 100 temperature sensor (order-no.: CPS 11-2 AA 2 TSA)
    • Redox combination electrode with platinum surface: measuring range up to 6 bar, 0 ... +130 °C (order-no.: CPS 12-0 PA 2 GSA)
  • Measuring cable: CPK 1 (for pH or Redox), CPK 7 (for pH with Pt 100)
  • Mounting devices for basin rim attachment: order-no.: 50066561
  • Support pipe: Minimum DN 50 required for applications with built-in agitator.

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.