Datasheet summary
iTemp TMT82
Engineering summary from PDF text extraction for iTemp TMT82. Verify every value with the OEM datasheet.
Summary
Product identification
- Product Name: iTEMP TMT82 HART® 7 temperature transmitter
- Description: Dual channel, SIL compliant temperature transmitter for use in hazardous areas.
Features and specifications
- Robust temperature transmitter delivering precise, long-term stable measurements for high plant availability.
- SIL certification up to SIL2, SC3 according to IEC 61508:2010.
- Versatile mounting and housing options: terminal head form B, DIN rail, field housing with separate terminal compartment, integrated display (TID10).
- Transmitter-sensor matching for highest measurement accuracy.
- Sensor and hardware failure detection; diagnostic status information according to NAMUR NE 107.
- Time-saving installation: Tool-free wiring with push-in terminal technology.
Operating limits
- Auxiliary power supply (head transmitter): 11 to 42 V DC
- Auxiliary power supply (DIN rail device): 12 to 42 V DC
- Auxiliary power supply (Ex ia): 11/12 to 30 V DC
Feed water
- Input: 2 x RTD, TC, Ohm, mV
Product water
- Output: 1 x analog 4 to 20 mA / HART
Electrical
- Communication: HART-protocol
- Galvanic isolation: Yes
Mechanical / hydraulic
- Installation: Terminal head form B, DIN-Rail housing or field mount housing.
Accuracy
- Pt100, -50 to 200 °C: ≤ 0.1 K
- Pt100, -58 to 392 °F: ≤ 0.18 °F
Certification
- ATEX II1G Ex ia IIC T4/T5/T6
- ATEX II3G Ex ic IIC T6
- ATEX II2D Ex tb IIIC Db
- ATEX II3D Ex tc IIIC Dc
- ATEX II3G Ex nA IIC T6
- ATEX II1G Ex ia IIC T6, II3D
- ATEX II3G Ex nA IIC T6, II3D
- ATEX II2G Ex d T6, II2D Ex tb IIIC
- CSA C/US General Purpose
- CSA IS, NI I / 1+2/A-D
- CSA XP, NI, DIP I, II, III/1+2/A-G
- FM IS, NI I / 1+2/A-D
- FM XP, NI, DIP I, II, III/1+2/A-G
- EAC Ex ia IIC T6 Ga
- EAC Ex d IIC T6 Gb
- EAC Ex ia IIC T6, II3D
- IECEx Ex ia IIC T4/T5/T6
- IECEx Ex tb IIIC Db
- IECEx Ex nA II T4/T5/T6
- IECEx Ex d T6 Gb, Ex tb IIIC Db
- INMETRO Ex ia [ia Ga] IIC T6 Gb
- INMETRO Ex d T6 Gb, Ex tb IIIC Db
- NEPSI Ex ia IIC T6 Ga
- NEPSI Ex d IIC T6 Gb
- NEPSI Ex nA IIC T6 Gc
- TIIS Ex ia IIC T6
- TIIS Ex nA II T6
- UK II1G Ex ia IIC T6 Ga
- UK II2D Ex tb IIIC Db
- UK II3D Ex tc IIIC Dc
- UK II1G Ex ia IIC T6 Ga, II3D Ex ia IIIC Dc
- UK II3G Ex nA IIC Gc, II3D Ex tc IIIC Dc
- UK II2G Ex db IIC T6 Gb, II2D Ex tb IIIC Db
- ATEX IECEx II1G Ex ia IIC T6 Ga
- FM+CSA IS, NI I/1+2/A-D
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.