Datasheet summary
iTemp TMT85
Engineering summary from PDF text extraction for iTemp TMT85. Verify every value with the OEM datasheet.
Summary
Product identification
- Product Name: iTEMP TMT85
- Product Type: Dual-input temperature transmitter
- Protocol: FOUNDATION Fieldbus™ H1
- Document: TI00134R/09/EN/08.22-00
Application
The iTEMP TMT85 is a temperature transmitter with two universal input channels and FOUNDATION Fieldbus™ protocol. It converts various input signals into digital output signals, offering reliability, long-term stability, high precision, and advanced diagnostic functions. It is suitable for critical processes and the highest levels of safety, reliability, and risk reduction.
Input
- Universal Input:
- Resistance thermometers (RTD)
- Thermocouples (TC)
- Resistance transmitters (Ω)
- Voltage transmitters (mV)
- Number of Channels: 2
- Input Signals: Temperature (temperature-linear transmission behavior), resistance, and voltage.
- Connection Combinations: Multiple combinations are possible between RTD/resistance transmitter (2-, 3-, or 4-wire) and Thermocouple/voltage transmitter inputs.
Measuring Range
- Resistance Thermometers (RTD):
- IEC 60751:2008 Pt100: –200 to +850 °C (–328 to +1 562 °F)
- IEC 60751:2008 Pt1000: –200 to +250 °C (–328 to +482 °F)
- JIS C1604:1984 Pt100: –200 to +649 °C (–328 to +1 200 °F)
- DIN 43760 Ni100: –60 to +250 °C (–76 to +482 °F)
- OIML R84: 2003 Cu50: –200 to +200 °C (–328 to +392 °F)
- Resistance Transmitter (Ω):
- 10 to 400 Ω
- 10 to 2,000 Ω
- Thermocouples (TC) as per IEC 60584, Part 1:
- Type K (NiCr-Ni): –270 to +1,372 °C (–454 to +2,501 °F)
- Type S (PtRh10-Pt): –50 to +1,768 °C (–58 to +3,214 °F)
- Type T (Cu-CuNi): –260 to +400 °C (–436 to +752 °F)
- Voltage Transmitter (mV):
- –20 to 100 mV
Output
- Output Signal: FOUNDATION Fieldbus™ H1, IEC 61158-2
- Data Transmission Rate: 31.25 kBit/s
- Output Data: Temperature (PV), temperature sensor 1 + 2, terminal temperature via AI blocks.
- LAS/LM Function: Supported, device can act as a Link Active Scheduler.
FOUNDATION Fieldbus™ Basic Data
- Device Type: 10CE (hex)
- Device Revision: 02
- ITK Version: 6.0.1
- Link Master Capability (LAS): Yes
Power Supply
- Supply Voltage: 9 to 32 V DC (max. 35 V DC)
Electrical Connection
- Terminals: Choice of screw terminals or push-in terminals.
- Screw terminals: Rigid or flexible cable, ≤ 2.5 mm² (14 AWG)
- Push-in terminals: Rigid or flexible cable, 0.2 to 1.5 mm² (24 to 16 AWG); flexible with wire end ferrules, 0.25 to 1.5 mm² (24 to 16 AWG).
Performance Characteristics
- Response Time: 1 s per channel
- Resolution: A/D converter resolution = 18 bit
- Maximum Measured Error: See the official PDF for exact tabulated values.
- Long-term drift: See the official PDF for exact tabulated values.
Operating Influences
- Ambient Temperature and Supply Voltage: Influences on resistance thermometers, resistance transmitters, thermocouples, and voltage transmitters are detailed in the official PDF.
- Example for Pt100 (IEC 60751:2008):
- Ambient temperature influence: 0.002% * (MV -LRV) per 1 °C change, at least 0.005 °C (0.009 °F).
- Supply voltage influence: 0.002% * (MV -LRV) per V change, at least 0.005 °C (0.009 °F).
- Example for Pt100 (IEC 60751:2008):
Mounting and Installation
- Installation Options:
- Terminal head form B (flat face) per DIN EN 50446.
- Separated in field housing for wall or pipe mounting.
- Clip on DIN rail per IEC 60715 (TH35).
- Orientation: No restrictions.
Environment
- Ambient Temperature Range: –40 to +85 °C (–40 to +185 °F) (for hazardous areas, see Ex documentation).
- Storage Temperature: –40 to +100 °C (–40 to +212 °F).
- Operating Altitude: Up to 4000 m (4374.5 yards) above sea level.
- Relative Humidity: Condensation permitted; max. 95% rel. humidity.
- Climate Class: C as per EN 60654-1.
- Degree of Protection:
- Head transmitter (screw terminals): IP 00; (push-in terminals): IP 30.
- In field housing TA30A, TA30D, TA30H: IP 66/67 (NEMA Type 4x).
- Shock and Vibration Resistance: Vibration resistance as per IEC 60068-2-6: 10 to 2,000 Hz at 5g.
- Electromagnetic Compatibility (EMC): CE conformity; Interference immunity as per IEC/EN 61326 series, industrial requirements; Interference emission as per IEC/EN 61326 series, Class B equipment.
- Overvoltage Category: Measuring category II per IEC 61010-1.
- Pollution Degree: Pollution degree 2 per IEC 61010-1.
Mechanical Construction
- Design: Available as a head transmitter or in field housings (TA30A, TA30D, TA30H).
- Weight:
- Head transmitter: approx. 40 to 50 g (1.4 to 1.8 oz).
- Field housing TA30A: 330 g (11.64 oz).
- Field housing TA30A with display window: 420 g (14.81 oz).
- Field housing TA30H (Aluminum): approx. 640 g (22.6 oz).
- Field housing TA30H (Stainless steel): approx. 2,400 g (84.7 oz).
- Field housing TA30H with display window (Aluminum): approx. 860 g (30.33 oz).
- Field housing TA30H with display window (Stainless steel): approx. 2,900 g (102.3 oz).
- Field housing TA30D: 390 g (13.75 oz).
- Materials: All materials used are RoHS-compliant. Housing: Polycarbonate (PC). See official PDF for detailed material specifications.
Operability
- Local Operation: Head transmitter has no display or operating elements, but an optional attachable measured value display (TID10) can be used.
- Remote Operation: Configuration via FOUNDATION Fieldbus™ communication using special configuration tools.
Certificates and Approvals
- CE Mark: Confirms compliance with EC directives.
- Ex Approval: Information available from Endress+Hauser Sales Center upon request.
- UL Approval: E225237
- CSA GP: General Purpose
- FOUNDATION Fieldbus™ Certification: Certified per FOUNDATION Fieldbus™ specification, H1, ITK revision 6.0.1.
Accessories
- Device-specific: TID10 display unit, field housings (TA30A, TA30D, TA30H), DIN rail mounting adapter, mounting sets, Fieldbus connectors, wall/pipe mounting brackets.
- Communication-specific: Commubox FXA291, Field Xpert SMT70.
- Service-specific: Applicator software, Configurator tool, DeviceCare SFE100, FieldCare SFE500, W@M lifecycle management.
Supplementary Documentation
- Operating Instructions
- Brief Operating Instructions
- Guideline FOUNDATION Fieldbus Function Blocks
- Supplementary ATEX documentation
- Operating Instructions for Display TID10