Datasheet summary
iTherm Moduline TM112
Engineering summary from PDF text extraction for iTherm Moduline TM112. Verify every value with the OEM datasheet.
Summary
Product Identification
- Product Name: iTHERM ModuLine TM112
- Type: Industrial modular thermometer
- Document: TI01793T/09/EN/01.24-00
Application
- Universal use
- Measuring range: –200 to +1 100 °C (–328 to +2 012 °F)
- Pressure range: up to 75 bar (1 088 psi)
Key Features
- iTHERM Inserts: Full traceability and high product quality.
- iTHERM QuickSens: Fastest response time of 1.5 s.
- iTHERM StrongSens: Unsurpassed vibration resistance (60g).
- Certifications: International certifications including ATEX, IECEx, CSA, INMETRO for explosion protection, and SIL for functional safety.
- iTEMP Transmitter: Supports common communication protocols and optional Bluetooth® connectivity.
Measuring Principle
Resistance Thermometers (RTD)
- Utilizes Pt100 sensors conforming to IEC 60751.
- Wire-Wound (WW): Suitable for temperatures up to 600 °C (1 112 °F), but more sensitive to vibrations.
- Thin-Film (TF): Smaller size and better vibration resistance. Tolerance Class A as per IEC 60751 up to approx. 300 °C (572 °F).
Thermocouples (TC)
- Based on the Seebeck effect.
- Measure temperature differences; absolute temperature requires knowledge of the cold junction temperature.
- Standardized by IEC 60584 and ASTM E230/ANSI MC96.1.
Input and Measuring Ranges
- Measured Variable: Temperature (temperature-linear transmission).
- Measuring Range (Examples):
- Pt100 thin film (TF), basic: –50 to +200 °C (–58 to +392 °F)
- Pt100 thin film (TF), iTHERM StrongSens: –50 to +500 °C (–58 to +932 °F)
- Pt100 wire wound (WW), extended: –200 to +600 °C (–328 to +1 112 °F)
- Thermocouple TC, type J: –40 to +750 °C (–40 to +1 382 °F)
- Thermocouple TC, type K: –40 to +1 100 °C (–40 to +2 012 °F)
Output and Transmitters
- Output Signal: Via directly-wired sensors or iTEMP transmitters.
- iTEMP Transmitters: Available with various communication protocols:
- 4 to 20 mA
- HART® (optional Bluetooth®)
- PROFIBUS® PA
- FOUNDATION™ Fieldbus™
- PROFINET® and Ethernet-APL™
- IO-Link®
- Field Transmitters: Available with HART®, FOUNDATION™ Fieldbus™, or PROFIBUS® PA communication.
Performance Characteristics
Maximum Measurement Error (RTD)
- Class A: ± (0.15 + 0.002 · |t|) °C
- Class AA: ± (0.1 + 0.0017 · |t|) °C
- Class B: ± (0.3 + 0.005 · |t|) °C (|t| = absolute temperature value in °C)
Response Time (Typical values in water, 0.4 m/s, 10 K change)
- Standard Pt100 (TF, WW): t50 = 5 s, t90 = 11 s
- iTHERM QuickSens: t50 = 0.5 s, t90 = 1.5 s
- Thermocouple (TC) Type J, K, N: t50 = 2.5 s, t90 = 7 s
Insulation Resistance
- RTD: > 100 MΩ at +25 °C (100 V DC)
- TC: > 1 GΩ at +20 °C (500 V DC); > 5 MΩ at +500 °C (500 V DC)
Installation
- Orientation: No restrictions, but self-draining is recommended depending on the application.
- Immersion Length: Influences measurement accuracy; at least half the pipe diameter is recommended for installation in pipes.
Environmental Conditions
- Ambient Temperature Range (Terminal Head):
- Without transmitter: Depends on head/gland.
- With iTEMP head transmitter: –40 to +85 °C (–40 to +185 °F).
- With iTEMP head transmitter and display: –20 to +70 °C (–4 to +158 °F).
- Storage Temperature: –40 to +85 °C (–40 to +185 °F).
- Humidity: Max. 95% relative humidity (non-condensing).
- Degree of Protection: Max. IP 66 (NEMA Type 4x), partly IP 68.
Shock and Vibration Resistance
- Exceeds IEC 60751 requirements (3g, 10-500 Hz).
- iTHERM StrongSens / QuickSens (ø6 mm): 600 m/s² (60g).
- Other types: Generally ≤ 30 m/s² (≤ 3g) or ≤ 40 m/s² (≤ 4g).
Process Conditions
- Process Temperature Range: –200 to +1 100 °C (–328 to +2 012 °F) (depends on sensor/material).
- Process Pressure Range:
- Max. 75 bar (1 088 psi) to +200 °C (+392 °F) for standard TF and QuickSens Pt100.
- Max. 50 bar (725 psi) to +400 °C (+752 °F) for other sensor types.
Mechanical Construction
- Insert Diameter (⌀ID): 3.175 mm (¹⁄₈ in), 6.35 mm (¹⁄₄ in), and others.
- Lagging Diameter (⌀D): 9.525 mm (³⁄₈ in) or 12.7 mm (¹⁄₂ in).
- Materials: Common materials include AISI 316/1.4401 (up to 650 °C) and Alloy 600/2.4816 (up to 1 100 °C).
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.