Back to Endress + Hauser temperature measurement
Endress+Hauser logo

Datasheet summary

iTherm-Moduline-TM402

Engineering summary from PDF text extraction for iTherm-Moduline-TM402. Verify every value with the OEM datasheet.

Summary

Product identification

The iTHERM Moduline TM402 is a resistance thermometer designed for hygienic and aseptic applications. It is part of a product line of modular thermometers for these specific environments. This model is the imperial version utilizing basic technology, characterized by a fixed, non-replaceable insert, and intended for use in non-hazardous areas.

Applications

  • Specially designed for hygienic and aseptic applications in the Food & Beverages and Life Sciences industries.
  • Can be used in non-hazardous areas.

Operating limits

  • Measuring range: –50 to +200 °C (–58 to +392 °F)
  • Pressure range: up to 40 bar (580 psi)
  • Protection class: up to IP69K

Feed water

The document does not specify feed water requirements.

Product water

The document does not specify product water quality parameters.

Electrical

  • Transmitter Outputs:
    • Analog output 4 to 20 mA, HART®
    • Bluetooth® connectivity (optional)
    • IO-Link®
  • Reference Conditions for Performance: Data relevant for determining the measurement accuracy of iTEMP transmitters.
  • Maximum Measured Error (RTD resistance thermometer as per IEC 60751):
    • Pt100 (TF) Basic:
      • Class B: –50 to +200 °C (–58 to +392 °F)
      • Class A: –50 to +200 °C (–58 to +392 °F)
      • Class AA: –30 to +200 °C (–22 to +392 °F)
    • Pt100 (TF) Standard:
      • Class B: –50 to +400 °C (–58 to +752 °F)
      • Class A: –50 to +400 °C (–58 to +752 °F)
      • Class AA: –30 to +250 °C (–22 to +482 °F)
    • Pt100 (TF) iTHERM QuickSens:
      • Class B: –50 to +200 °C (–58 to +392 °F)
      • Class A: –50 to +200 °C (–58 to +392 °F)
      • Class AA: –30 to +200 °C (–22 to +392 °F)
    • Pt100 (TF) iTHERM StrongSens:
      • Class B: –50 to +500 °C (–58 to +932 °F)
      • Class A: –50 to +500 °C (–58 to +932 °F)
      • Class AA: –30 to +300 °C (–22 to +572 °F)
    • Pt100 (WW):
      • Class B: –200 to +600 °C (–328 to +1112 °F)
      • Class A: –200 to +600 °C (–328 to +1112 °F)
      • Class AA: –100 to +450 °C (–148 to +842 °F)
  • Self-heating: Negligible when an Endress+Hauser iTEMP temperature transmitter is connected.
  • Response time (t₅₀ / t₉₀) in water at 0.4 m/s (1.3 ft/s) for 1x Pt100 thin-film sensor:
    • ⌀6.35 mm (¹⁄₄ in) Straight tip: 5 s / 11 s
    • Reduced 4.76 mm (³⁄₁₆ in) x 19.05 mm (0.75 in) tip: 3.5 s / 9 s
    • ⌀9.53 mm (³⁄₈ in) Reduced tip: 5 s / 10.5 s
  • Insulation resistance: ≥ 100 MΩ at ambient temperature.

Mechanical / hydraulic

  • Process temperature range: –50 to +200 °C (–58 to +392 °F)
  • Thermal shock resistance: +5 to +130 °C (+41 to +266 °F) within 2 seconds (CIP/SIP).
  • Process pressure range: Maximum pressure depends on design, process connection, and temperature. For example, with specific weld-in adapters, 40 bar (580 PSI) is possible at max. 100 °C (212 °F).
  • Materials:
    • Wetted parts typically AISI 316L.
  • Surface roughness (wetted surfaces):
    • Standard surface, mechanically polished: Ra ≤ 0.76 µm (30 µin)
    • Mechanically polished, buffed: Ra ≤ 0.38 µm (15 µin) (Not compliant with ASME BPE)
  • Terminal heads:
    • TA30A: IP66/68, temperature –50 to +150 °C (–58 to +302 °F), aluminum.
    • TA30R: IP69K (standard), IP66/68 (display window), temperature –50 to +130 °C (–58 to +266 °F), stainless steel 316L.
    • TA30S: IP65, temperature –40 to +85 °C (–40 to +185 °F), polypropylene (PP), FDA-compliant.
  • Process connections:
    • Clamp according to ISO 2852 (Form A/B)
    • Tri-clamp ¾" (DN18) Form A: Pmax. = 16 bar (232 psi)
    • Clamp ISO 2852 ½" to 2" (Form B): Pmax. = 16 bar (232 psi)
    • L1 thread (ISO 228): Pmax. = 25 bar (362 psi) at 150 °C (302 °F) or 40 bar (580 psi) at 100 °C (212 °F).
    • Varivent® Type F: Pmax. = 10 bar (145 psi).
    • Varivent® Type N (DIN 11866): Pmax. = 16 bar (232 psi) or 10 bar (145 psi) depending on size.
  • Tip shape: Straight, Reduced tip with ⌀4.76 mm (³⁄₁₆ in), Reduced tip for Tee and Elbow with ⌀4.5 mm (0.18 in).
  • Thermowell diameters: ⌀6.35 mm (¹⁄₄ in), ⌀9.53 mm (³⁄₈ in), ⌀12.7 mm (¹⁄₂ in).

Certificates and approvals

  • ASME BPE
  • 3-A (Authorization number 1144)
  • EHEDG (Type EL CLASS I)
  • FDA-compliant