Summary
Product identification
- Product Name: iTEMP TMT182B
- Product Type: Temperature transmitter
- Protocol: HART®
Application
The iTEMP TMT182B is a universal temperature transmitter featuring HART® communication. It converts various input signals into a scalable, analog 4-20 mA output signal. Key characteristics include reliability, long-term stability, high precision, and advanced diagnostic functions suitable for critical processes. It is designed for enhanced safety, reliability, and risk reduction.
The device offers universal input for:
- Resistance thermometers (RTD)
- Thermocouples (TC)
- Resistance transmitters (Ω)
- Voltage transmitters (mV)
It is designed for installation in a terminal head, form B (flat face).
Input
Measured variable
- Temperature (with temperature-linear transmission behavior)
- Resistance
- Voltage
Measuring range
Resistance Thermometers (RTD):
- IEC 60751:2022:
- Pt100: –200 to +850 °C
- Pt200: –200 to +850 °C
- Pt500: –200 to +500 °C
- Pt1000: –200 to +250 °C
- Min. span: 10 K
- JIS C1604:1984:
- Pt100: –200 to +510 °C
- Min. span: 10 K
- DIN 43760 IPTS-68:
- Ni100: –60 to +250 °C
- Ni120: –60 to +250 °C
- Min. span: 10 K
- GOST 6651-94:
- Pt50: –185 to +1100 °C
- Pt100: –200 to +850 °C
- Min. span: 10 K
- OIML R84:2003, GOST 6651-2009:
- Cu50: –180 to +200 °C
- Cu100: –180 to +200 °C
- Ni100: –60 to +180 °C
- Ni120: –60 to +180 °C
- Cu50: –50 to +200 °C
- Min. span: 10 K
Resistance Transmitter:
- 10 to 400 Ω
- 10 to 2 000 Ω
- Min. span: 10 Ω
Thermocouples (TC):
- IEC 60584, Part 1 / ASTM E230-3:
- Type A: 0 to +2 500 °C
- Type B: +40 to +1 820 °C
- Type E: –250 to +1 000 °C
- Type J: –210 to +1 200 °C
- Type K: –270 to +1 372 °C
- Type N: –270 to +1 300 °C
- Type R: –50 to +1 768 °C
- Type S: –50 to +1 768 °C
- Type T: –200 to +400 °C
- Min. span: 50 K
- IEC 60584, Part 1 / ASTM E988-96:
- Type C: 0 to +2 315 °C
- Type D: 0 to +2 315 °C
- Min. span: 50 K
- DIN 43710:
- Type L: –200 to +900 °C
- Type U: –200 to +600 °C
- Min. span: 50 K
- GOST R8.585-2001:
- Type L: –200 to +800 °C
- Min. span: 50 K
Voltage Transmitter (mV):
- –20 to 100 mV
- Min. span: 5 mV
Sensor connections
- RTD/Ω: 2-wire, 3-wire, or 4-wire connection. Sensor current: ≤ 0.3 mA.
- 2-wire: Compensation of wire resistance up to 30 Ω possible.
- 3-wire and 4-wire: Sensor wire resistance up to max. 50 Ω per wire.
- TC/mV: Maximum sensor wire resistance 10 kΩ.
Output
- Analog Output: 4 to 20 mA, 20 to 4 mA (invertible)
- Signal Encoding: FSK ±0.5 mA via current signal
- Data Transmission Rate: 1200 baud
- Galvanic Isolation: U = 2 kV AC for 1 minute (input/output)
- Failure Information: As per NAMUR NE43. Configurable underranging (≤ 3.6 mA) or overranging (≥ 21 mA) for sensor failures.
- Load: Rb max.= (Ub max. - 10 V) / 0.023 A (current output)
- Linearization/Transmission Behavior: Temperature-linear, resistance-linear, voltage-linear
- Filter: 1st order digital filter, 0 to 120 s
Protocol-specific data (HART®)
- Manufacturer ID: 17 (0x11)
- Device Type ID: 0x11D2
- HART® Specification: 7
- Device Address: Software setting addresses 0 to 63 (multi-drop mode)
- HART Load: Minimum 250 Ω
- HART Device Variables: Primary value (PV), Sensor (measured value), SV, TV, QV (device temperature, sensor value)
- Minimum Starting Voltage: 10 VDC
- Start-up Current: 3.58 mA
- Start-up Time: 7 s
- Minimum Operating Voltage: 10 VDC
- Multidrop Current: 4.0 mA
- Time for Connection Setup: 9 s
Power supply
- Non-hazardous areas: 10 to 36 VDC (protected against polarity reversal)
- Hazardous areas: See Ex documentation.
- Current Consumption: 3.6 to 23 mA (minimum 3.5 mA, current limit ≤ 23 mA)
Electrical connection
- Terminals: Screw terminals
- Cable Cross-section: ≤ 1.5 mm² (16 AWG)
Performance characteristics
- Response Time: ≤ 1 s (for RTD, Ω, TC, mV)
- Refresh Time: Approx. 100 ms
- Reference Operating Conditions: Calibration temperature +25 °C ±3 K, Supply voltage 24 V DC, 4-wire circuit for resistance adjustment.
- Maximum Measured Error: Data provided for various RTD types, thermocouples, and resistance transmitters based on digital and analog output, with typical and standard values. See the official PDF for exact tabulated values.
Installation
- Mounting Location: Terminal head, form B (flat face) as per DIN EN 50446, or on DIN rail using an adapter clip.
- Orientation: No restrictions.
Environment
- Ambient Temperature: –40 to +85 °C (for hazardous areas, see Ex documentation)
- Storage Temperature: –50 to +100 °C
- Operating Altitude: Up to 4 000 m above sea level
- Humidity: Max. 95% relative humidity (non-condensing), permitted.
- Climate Class: C1 as per IEC 60654-1
- Degree of Protection: IP 20 with screw terminals (installed state depends on terminal head/housing).
Mechanical construction
- Weight: 40 to 50 g
- Materials: All materials are RoHS-compliant.
- Housing: Polycarbonate (PC)
- Terminals: Screw terminals, nickel-plated brass and gold-plated or tin-plated contacts
- Potting: QSIL 553
Operability
- Remote Operation: Configuration via HART® communication or CDI interface using dedicated configuration tools.
Certificates and approvals
- HART® Certification: Registered by the FieldComm Group™, meets HART® Communication Protocol Specifications, Revision 7.
- MTTF: 168 years
Accessories
Various accessories are available, including:
- Device-specific: Field housing TA30x, DIN rail mounting adapter, DIN mounting set, US M4 securing screws.
- Communication-specific: Commubox FXA195, Commubox FXA291, WirelessHART adapter, Field Xpert SMT70 tablet PC.
- Service-specific: Applicator software, Product Configurator software, DeviceCare SFE100, FieldCare SFE500.
- System Components: RN22 active barrier, RN42 active barrier, RIA15 process display.