Datasheet summary
Omnigrad-S TR15, TC15
Engineering summary from PDF text extraction for Omnigrad-S TR15, TC15. Verify every value with the OEM datasheet.
Summary
Product identification
- Product Name: Omnigrad S - TC 15
- Type: Thermocouple thermometer with replaceable insert and bar stock thermowell.
- Electronics Options: PCP (4...20 mA), HART®, or PROFIBUS-PA®.
- Standards: Modular configuration and structure defined in DIN 43772 (form 4/4F).
Areas of application
Designed for heavy industrial processes, particularly in applications involving steam and gases at high pressures and temperatures. Sectors include:
- Chemical industry
- Energy industry
Function and system design
Measuring principle
Utilizes the Seebeck effect where a temperature difference between the "hot" (measurement) junction and the "cold" (reference) junction of two dissimilar homogeneous metal wires generates an electromotive force. Cold junction compensation to 0°C is required. Thermocouple curves comply with DIN EN 60584 and ANSI MC96.1 standards for industrial readings.
Equipment architecture
The sensor comprises a measurement probe (replaceable insert) within a thermowell, and a housing. Construction is based on DIN 43729 (housing), 43772 (thermowell), and 43735 (probe). The insert is spring-loaded for improved heat transfer.
- Thermowell Diameter: 18 mm or 24 mm.
- Thermowell Tip Diameter: 9 mm or 12.5 mm.
- Insert Diameter: 3 mm or 6 mm.
- Process Connection: Weld-in or flanged.
- Housing Materials: Plastic, painted aluminium alloy, or stainless steel, with IP65 minimum.
Material
- Wetted parts: SS 316Ti/1.4571 or 13CrMo4-5/1.7335.
Performance
Operating conditions
- Ambient temperature (housing without transmitter):
- Metal housings: -40 to 130°C
- Plastic housings: -40 to 85°C
- Ambient temperature (housing with transmitter): -40 to 85°C
- Ambient temperature (housing with display): -20 to 70°C
- Process temperature (restricted by thermowell material):
- SS 316 Ti/1.4571: < 800°C
- 13CrMo4-5/1.7335: < 800°C
Maximum process pressure
Pressure values are dependent on temperature and thermowell type, as illustrated in figures and Table 1.
Maximum flow velocity
Diminishes with increasing exposed length of the well/probe. Information available in figure 2.
Shock and vibration resistance
According to DIN EN 60751: 3 g peak / 10–500 Hz.
Accuracy
Thermocouple tolerances
Tolerances are defined by DIN EN 60584 and ANSI MC96.1 standards. See Table 2 for details on Class 1/special accuracy for types J and K.
Transmitter maximum error
See the corresponding documentation for head-mounted transmitters.
Display maximum error
0.1% of the set span + 1 digit.
Measurement range
Defined ranges are shown in Table 3.
Response time
Tests in water at 0.4 m/s (23 to 33°C) according to DIN EN 60751 are detailed in Table 4 for various stem diameters, thermocouple types, and junction configurations.
Insulation
- Insulation resistance between terminals and probe sheath: > 1 GΩ at 25°C, > 5 MΩ at 500°C (according to DIN EN 60584, test voltage 500 V).
Installation
- Can be installed on pipes, tanks, and other plant parts.
- Interface components and gaskets are customer's responsibility.
- Immersion depth: Crucial for accuracy; recommended minimum immersion depth of 100–150 mm. Probe tip should reach or slightly exceed the duct axis in small pipes.
- Corrosion: SS 316Ti/1.4571 tolerates common corrosive media up to high temperatures.
- Electromagnetic noise: Grounded hot junction is not recommended.
- Thermowell testing for specific operating conditions is available upon request.
System components
Housing
Available in plastic, painted aluminium alloy, and stainless steel. Minimum IP65 grade ensured by coupling and cable gland. Complies with DIN 43729 (form B). Connection: M24x1.5. Various housing types (TA20A, TA20B, TA21E, TA20D, TA20J, TA20R, TA20W) offer different features and IP grades.
Head transmitter
Available head-mounted transmitters:
- TMT 181: PCP 4…20 mA
- TMT 182: Smart HART®
- TMT 184: PROFIBUS-PA®
Transmitters are programmable using PC software (ReadWin® 2000, FieldCare, CommuWin II) or a HART® communicator (DXR 275). PROFIBUS-PA® requires dedicated connectors.
Extension neck
Tube of 11 mm in SS 316Ti/1.4571.
- Lower connection: M14x1.5 (for 18 mm thermowells) or M18x1.5 (for 24 mm thermowells).
- Length (E): 155 mm (for L=110 mm thermowell) or 165 mm (for other lengths).
- Upper connection allows head orientation.
Process connection
- Standard types: Weld-in, ANSI B16.5 cl. 150 and 300 RF flange, EN 1092 flange.
- Thermowell marked near connection per DIN 43772.
Probe
Mineral oxide (MgO) insulated insert.
- Insert length (IL): Available in standard DIN 43772 dimensions or can be personalized. Must comply with thermowell immersion length (L).
- Thermowell diameter 18 mm: Maximum length (L) of 200 mm.
Certificates & Approvals
- PED approval: Complies with Pressure Equipment Directive (97/23/CE).
- Material certification: 3.1.B (EN 10204) available for wetted parts. "Short form" certificate also available.
- Test on thermowell: Hydrostatic internal/external pressure tests and dye penetrant tests can be performed.
Maintenance
No specific maintenance required for Omnigrad S thermometers.
Delivery time
For small quantities (10–15 units) and standard options: 10 to 15 days.