Datasheet summary
Omnigrad TA550
Engineering summary from PDF text extraction for Omnigrad TA550. Verify every value with the OEM datasheet.
Summary
Product identification
- Product: Omnigrad TA550
- Type: Heavy duty - General purpose thermowell
- Construction: From round bar stock
- Standard Reference: ME U 819.02 - type 2
Description
The TA550 is an industrial standard thermowell manufactured from drilled round bar stock with a diameter of Ø 30 mm. It is designed for use with resistance and thermocouple thermometers, particularly in heavy-duty applications. The process connection can be threaded or flanged weld, and the stem can be straight or conical. Various extension and immersion lengths, bar dimensions, materials, and surface finishes are available.
Technical data
- Extension O.D.: 30 mm
- Immersion O.D.: < 22 mm
- Standard extension length: 70 mm
- Standard bore diameter: 7 mm or 8 mm
- Standard material: AISI316 / W.1.4401, AISI316L / W.1.4404
Connection to thermometer
- Threaded: 1/2" NPT - female
Process connection
- Type: Threaded or flanged weld
- Thread: 3/4" NPT
- Flange type: ANSI slip-on
- Flange material: AISI 316 or A 105
- Flange mounting: Threaded and back welded - 3x3 mm wide
Tip
- Bottom shape: Straight or conical
- Standard bottom thickness: 6 mm
Surface Finishing
- Refer to the order key for available options (e.g., 1.6 micron, 0.8 micron).
Order key structure
The order key specifies configuration details such as:
- Extension: Length (A), tapered options (T, Q1, Q2)
- Immersion Length: (U) range from 60-930 mm
- Thermowell Type: Price per mm (A)
- Material: SS316 / 1.4401 (C), SS316L / 1.4404 (D)
- Finishing of immersion length: (e.g., 1.6 micron, 0.8 micron)
- Process connection type: Threaded (AA - 3/4" NPT), various ANSI flange options (CD, CH, CK, CP, CV, CX)
- Flange finishing: Standard for ASME/ANSI (2), as specified (9)
- Thermowell bore diameter (F): 7 mm (1), 8 mm (2)
- Plug and chain: Safety plug options (B)
- Markings: None (0), Punched as specified (1)
Notes on Order Key:
- Minimum wall thickness (Q2 - F) / 2 ≥ 3 mm.
- Nominal length (A) range: 130 ÷ 1000 mm.
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.