Back to Endress + Hauser temperature measurement
Endress+Hauser logo

Datasheet summary

Omnigrad TA556

Engineering summary from PDF text extraction for Omnigrad TA556. Verify every value with the OEM datasheet.

Summary

Product identification

  • Product Name: Omnigrad TA556
  • Product Type: Industrial protecting tube / Thermowell
  • Description: Heavy duty - General purpose thermowell manufactured from round bar stock (drilled).
  • Standard Reference: ENI BAR 3 & BAR 4

Application

Designed for use with resistance and thermocouple thermometers, mainly in heavy duty applications.

Technical data

  • Round bar O.D.: 35 mm
  • Extension O.D.: 35 mm
  • Immersion O.D.: < 28 mm
  • Standard extension length: 100 mm
  • Standard bore diameter: 10 or 14 mm
  • Standard material: AISI316/W.1.4401, AISI316L/W.1.4404

Process connection

  • Type: Threaded or flanged weld
  • Thread: 1" NPT
  • Flange type: ANSI slip-on
  • Flange material: AISI 316 or A 105
  • Flange mounting: threaded and back welded - 3x3 mm wide

Tip

  • Bottom shape: Straight or tapered
  • Standard bottom thickness: 5 mm

Surface Finishing

Refer to the order key.

Order Key

The order key allows for customization of the thermowell. Key parameters include:

  • Extension, thermowell shape and type: Options for nominal length (A) and details like ENI BAR specifications.
  • Immersion Length (U): Configurable from 60-900 mm.
  • Thermowell type, price per mm (A): Material options include SS316 / 1.4401 and SS316L / 1.4404. Special versions are available.
  • Finishing of immersion length: Options for surface roughness (e.g., 1.6 micron, 0.8 micron).
  • Process connection type: Various ANSI flanged slip-on options (1", 1 1/2", 2" in different pressure classes and types) and a 'none' option for 1" NPT. Special versions are available.
  • Flange finishing: Options include not required, standard for ASME/ANSI, or as specified.
  • Thermowell bore diameter (F): Options for ENI BAR 4 (10mm bore) or ENI BAR 3 (14mm bore). Special versions are available.
  • Plug and chain: Options for no safety plug or a safety plug with a chain.
  • Markings: Options for no markings or punched markings.

Notes:

  • Minimum wall thickness 3 mm: (Q2 - F) / 2 ≥ 3 mm
  • Nominal length (A): 160 ÷ 1000 mm

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.