Datasheet summary
Thermophant TTR31
Engineering summary from PDF text extraction for Thermophant TTR31. Verify every value with the OEM datasheet.
Summary
Product Identification
The Thermophant T TTR31 is a temperature switch with threaded connections or compression fitting. The Thermophant T TTR35 is designed for hygienic applications.
Applications
These devices monitor, display, and control process temperatures in the range of –50 to 200 °C (–58 to 392 °F). Specific applications include:
- Hygienic applications (TTR35)
- Electronic versions with:
- One PNP switch output
- Two PNP switch outputs
- Two PNP switch outputs or one PNP switch output and a 4 to 20 mA active output
Key Features and Benefits
- Compact design with integrated switching electronics for decentralized monitoring.
- High reproducibility and long-term stability.
- On-site function check and information via LEDs and digital display.
- Platinum temperature sensor (Pt100, Cl. A as per IEC 60751) with long-term stability.
- High accuracy across the ambient temperature range and short response time.
- Operable and visualizable with PC and FieldCare configuration software.
- Top housing section can be rotated 310°.
- DESINA-compliant.
- 3-A mark and EHEDG certification for TTR35.
Measuring Principle
The devices use a platinum sensor (Pt100) whose resistance changes with temperature. This resistance is converted electronically. The resistance-temperature relationship follows IEC 60751.
Measuring System
- Sensor: Pt100
- Field of application: Measurement, monitoring, and control of process temperatures. For hygienic processes with the TTR35.
- Process Connection:
- TTR31: Compression fitting or threaded connections (G½", G¼", NPT¼", NPT½").
- TTR35 (Hygienic): Conical metal-metal G½", Clamp 1" - 1½", 2", Varivent F/N, DIN 11851, APV Inline.
Measuring Range
- Standard: –50 to 150 °C (–58 to 302 °F)
- With extension neck: –50 to 200 °C (–58 to 392 °F)
- Hygienic applications (TTR35): –50 to 150 °C (–58 to 302 °F), or up to 200 °C (392 °F) with extension neck.
- Minimum Span: 20 K (36 °F)
Output
- Signal Type: DC voltage version
- 1x PNP switch output
- 2x PNP switch outputs
- 1x PNP switch output and 4 to 20 mA output (active)
- Signal on Alarm:
- Analog output: ≤ 3.6 mA or ≥ 21.0 mA
- Switch outputs: Safe state (switch open)
- Switching Capacity:
- Switch ON: Ia ≤ 250 mA
- Switch OFF: Ia ≤ 1 mA
- Voltage drop PNP: ≤ 2 V
- Switching Cycles: > 10,000,000
- Range of Adjustment:
- Switch point (SP) and switchback point (RSP) in 0.1 °C (0.18 °F) increments. Minimum difference between SP and RSP is 0.5 °C (0.8 °F).
- Lower Range Value (LRV) and Upper Range Value (URV) for analog output configurable within the sensor range.
- Damping: Configurable from 0 to 40 s in 0.1 s increments.
Power Supply
- Supply Voltage: 12 to 30 VDC (reverse polarity protection).
- Current Consumption: < 60 mA (without load, with reverse polarity protection).
Performance Characteristics
- Reference Operating Conditions: As per DIN IEC 60770 or DIN IEC 61003 at T = 25 °C (77 °F).
- Maximum Measured Error (Switch Point & Display):
- Electronics: 0.2 K (0.36 °F)
- Sensor: Class A as per IEC 60751. Maximum error = ± 0.15 + 0.002 · |T| °C.
- Total Error:
- –50 to +75 °C: ≤ 0.5 K (0.9 °F)
- +75 to +200 °C: ≤ 0.75 K (1.35 °F)
- Switch Point Non-Reproducibility: 0.1 K (0.18 °F) as per EN 61298-2.
- Long-Term Drift: ≤ 0.1 K (0.18 °F) per year under reference conditions.
- Sensor Response Time:
- t₅₀: 100 ms
- t<0xE2><0x82><0x90>₀: < 1.0 s
- Switch Output Response Time: 100 ms
- Analog Output Rise Time (t<0xE2><0x82><0x90>₀): ≤ 200 ms
- Analog Output Settling Time (t<0xE2><0x82><0x99>₉): ≤ 500 ms
- Long-Term Reliability: Mean Time Between Failure (MTBF) > 100 years.
Environmental Limits
- Ambient Temperature Range: –40 to +85 °C (–40 to +185 °F)
- Storage Temperature: –40 to +85 °C (–40 to +185 °F)
- Operating Altitude: Up to 4,000 m (13,123.36 ft) above sea level.
- Degree of Protection:
- IP65 (M16 x 1.5 or NPT ½" valve connector)
- IP66 (M12 x 1 connector)
- Shock Resistance: 50 g as per DIN IEC 68-2-27 (11 ms).
- Vibration Resistance: 20 g as per DIN IEC 68-2-6 (10-2000 Hz); 4 g as per marine approval.
- Electromagnetic Compatibility (EMC): In accordance with IEC/EN 61326 series and NAMUR Recommendation EMC (NE21). Interference emission Class B.
Process Limits
- Process Temperature Range: –50 to +150 °C (–58 to +302 °F), or –50 to +200 °C (–58 to +392 °F) with extension neck. Restrictions apply based on ambient temperature and process connection.
- Process Pressure Range: Maximum permitted process pressure depends on insertion length. See the diagram provided. For the conical metal-metal hygienic process connection (MB option), the maximum pressure is 1.6 MPa = 16 bar (232 psi).
- Permitted Flow Velocity: Depends on insertion length. See the diagram provided.
Mechanical Construction
- Materials:
- Process connection: AISI 316L
- Surfaces in contact with the process (hygienic version): Ra ≤ 0.76 µm (30 µin).
- Coupling nut: AISI 304
- Housing: AISI 316L
- O-rings: EPDM, FKM
- Electrical connection components: Polyamide (PA), Polycarbonate (PC-FR), Polyurethane (PUR).
- Weight: Approximately 300 g (10.58 oz), depending on process connection and sensor length.
Operability
- Local Operation: Menu-guided operation via keys. Functions include unit selection, zero point adjustment, damping configuration, display settings, switch output configuration (hysteresis/window, NC/NO), analog output configuration, and service functions (reset, lock, error display, simulation).
- Remote Operation: Operation, visualization, and maintenance can be performed via PC using ReadWin 2000 or FieldCare configuration software.
Certificates and Approvals
- CE Mark: Conforms to EU directives.
- Other Standards: IEC 60529 (IP code), IEC/EN 61010-1, IEC/EN 61326 series, NAMUR, NEMA.
- UL Approval: More information available via UL Product iq™ (keyword: E225237).
- Hygiene Standards:
- EHEDG certification (Type EL CLASS I).
- 3-A Authorization (No. 1144, 3-A Sanitary Standard 74-07).
- FDA-compliant materials.
- Materials in Contact with Food/Product (FCM): Comply with relevant European regulations ((EC) No. 1935/2004, (EC) No. 2023/2006, (EC) No. 10/2011). Free from materials derived from bovine animals or other livestock (ADI/TSE).
- Material Certification: Material certificate 3.1 (EN 10204) can be requested separately.
Accessories
- Device-Specific: Welding boss, compression fitting.
- Communication-Specific: M12x1 couplings (straight, elbowed), connecting cables (PVC), configuration kits (TXU10-AA, FXA291).
- System Components: Easy Analog RNB130 power supply, Process Indicator RIA452.
Disclaimer: Extraction may miss figures, footnotes, or revisions; contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.