RTD TR15, TC15

Engineering summary from PDF text extraction for RTD TR15, TC15. Verify every value with the OEM datasheet.

Summary

Product Identification

  • TR15: Resistance Thermometer (RTD)
  • TC15: Thermometer with Thermocouple (TC)

Application

  • Universal range of application
  • Suitable for steam and gas applications with high process pressures and temperatures
  • Static pressure range up to 400 bar (5 800 psi)
  • Degree of protection up to IP68

Measuring Range

  • Resistance Insert (RTD): –200 to 600 °C (–328 to 1 112 °F)
  • Thermocouple (TC): –40 to 1 100 °C (–40 to 2 012 °F)

Input Sensor Specific Ranges

  • Pt100 thin-film: –50 to +400 °C (–58 to +752 °F)
  • Pt100 thin-film, iTHERM StrongSens: –50 to +500 °C (–58 to +932 °F)
  • Pt100 wire wound, extended: –200 to +600 °C (–328 to +1 112 °F)
  • Thermocouple TC, type J: –40 to +750 °C (–40 to +1 382 °F)
  • Thermocouple TC, type K: –40 to +1 100 °C (–40 to +2 012 °F)

Output

  • Directly-wired sensors: Sensor values forwarded without a transmitter.
  • Head transmitters:
    • Analog output 4 to 20 mA
    • HART®
    • PROFIBUS® PA
    • FOUNDATION Fieldbus™
    • PROFINET® and Ethernet-APL

Operating Conditions

Ambient Temperature Range

  • Terminal head without mounted head transmitter: Depends on terminal head and cable gland/fieldbus connector.
  • Terminal head with mounted head transmitter: –40 to 85 °C (–40 to 185 °F)
  • Terminal head with mounted head transmitter and display: –20 to 70 °C (–4 to 158 °F)

Process Pressure (Static)

  • Weld-in version: Max. 400 bar (5 800 psi)
  • Flange (EN1092-1 or ISO 7005-1): 20, 40, 50, or 100 bar depending on flange pressure rating.
  • Flange (ANSI B16.5): 150 or 300 psi depending on flange pressure rating.
  • Flange (JIS B 2220): 20K, 25K or 40K depending on flange pressure rating.

Mechanical / Hydraulic

Materials

  • Extension neck and thermowell materials: AISI 316L/1.4404, 1.4435, AISI 316Ti/1.4571, AISI A105/1.0460, Duplex SAF2205/1.4462, Inconel 600/2.4816, Hastelloy C276/2.4819, AISI A182 F11/1.7335, Titanium/3.7035, 1.5415 (16Mo3).
  • Recommended max. temperature for continuous use in air: Varies by material, from 300 °C (572 °F) for Duplex to 1 100 °C (2 012 °F) for Inconel and Hastelloy.

Terminal Heads

  • TA30A: IP66/68, –50 to +150 °C (–58 to +302 °F), Aluminum.
  • TA30A with display window: IP66/68, –50 to +150 °C (–58 to +302 °F), Aluminum.
  • TA30D: IP66/68, –50 to +150 °C (–58 to +302 °F), Aluminum. Can mount two head transmitters.
  • TA30P: IP65, –40 to +120 °C (–40 to +248 °F), Polyamide. Intrinsically safe (Ex ia).
  • TA20B: IP65, –40 to +80 °C (–40 to +176 °F), Polyamide.
  • TA21E: IP65, –40 to 130 °C (–40 to 266 °F), Aluminum alloy.
  • TA20J: IP66/67, –40 to 70 °C (–40 to 158 °F), Stainless steel (316L). Features LC display.
  • TA20R: IP66/67, –40 to +100 °C (–40 to +212 °F), Stainless steel (316L).

Thermowell Diameters

  • 18 mm (0.71 in), 24 mm (0.94 in), or 26 mm (1.02 in).

Insert Diameters

  • 3 mm (0.12 in) or 6 mm (0.24 in).

Electrical

  • Output Signals: 4 to 20 mA, HART®, PROFIBUS® PA, FOUNDATION Fieldbus™, PROFINET®.

Accuracy

  • Thermocouple Accuracy: Refer to IEC 60584 and ASTM E230/ANSI MC96.1 for standard and special tolerances.
  • RTD Accuracy: Refer to IEC 60751 for Class A, AA, and B tolerances.

Response Time

  • Calculated at approx. 23 °C in running water (0.4 m/s flow rate, 10 K excess temperature). Specific values vary based on thermowell diameter, tip length, and sensor type (RTD/TC).
  • Example for RTD, 18 mm thermowell, U=65 mm: t50 = 22 s, t90 = 60 s.
  • Example for TC, 18 mm thermowell, U=65 mm, grounded: t50 = 7 s, t90 = 18 s.
  • Insert response times: Faster values are provided for the insert alone, tested in flowing water.

Insulation Resistance

  • RTD: > 100 MΩ at 25 °C (100 V DC).
  • TC: > 1 GΩ at 20 °C and > 5 MΩ at 500 °C (500 V DC).

Dielectric Strength

  • Ø6 mm: ≥ 1 000 V DC between terminals and sheath.
  • Ø3 mm: ≥ 250 V DC between terminals and sheath.

Calibration

  • Endress+Hauser provides comparison temperature calibration from –80 to +1 400 °C (–110 to +2 552 °F) based on ITS90. Calibrations are traceable to national/international standards.