Summary
Product Identification
The AQM 60 is an integrated multi-gas monitor capable of delivering high quality data for up to six gases in ambient air environments.
General Specifications
Gas Sensors
- Ozone (Ultra-low)
- Range: 0 - 150 ppb
- Resolution: 1 ppb
- Ozone (Low)
- Range: 0 - 500 ppb
- Resolution: 1 ppb
- Nitrogen dioxide
- Range: 0 - 200 ppb
- Resolution: 1 ppb
- Carbon monoxide
- Range: 0 - 100 ppm
- Resolution: 0.1 ppm
- Sulphur dioxide
- Range: 0 - 10 ppm
- Resolution: 0.01 ppm
- VOC (Non-Methane Hydrocarbon)
- Range: 0 - 25 ppm
- Resolution: 0.1 ppm
- VOC (Toluene)
- Range: 0 - 500 ppm
- Resolution: 1 ppm
- Hydrogen sulphide
- Range: 0 - 10 ppm
- Resolution: 0.01 ppm
- Ammonia
- Range: 0 - 100 ppm
- Resolution: 1 ppm
- Halogenated hydrocarbons
- Range: 0 - 500 ppm
- Resolution: 1 ppm
- Carbon dioxide (NDIR)
- Range: 0 - 2000 ppm
- Resolution: 10 ppm
Contact Aeroqual for other calibrations.
Zero Air Scrubber
- Type: Triple media (Hopcalite, activated carbon and alumina)
- Zero calibration: Programmable or external activation
Pump
- Type: Brushless rotary vane
Sample Gas Line Materials
- Materials: PFA Teflon, PTFE, Kynar
Connections
- Air inlet / exhaust: 3 mm Kynar barb
- Communications: 4-way M12 female
Communications
- Protocol: RS232 or RS485 (analog 0-5 V outputs optional)
- Data transfer: Polling or pushing
- Data sampling rate: 2 minutes
Power Requirements
- Voltage: 24VDC / 1A
Enclosure (Internal)
- Material: Fibre Reinforced Polycarbonate (FRP)
- Dimensions: 361 x 254 x 165 mm
- Weight: < 10 Kg
Approvals
- Part 15 of FCC Rules
- EN 61000-6-3: 2001
- EN 61000-6-1: 2001
Optional Modules
Temperature & Humidity
- Temperature sensor: -20°C - 100°C, 0.01°C resolution
- Relative humidity sensor: 0 - 100% RH, 1% resolution
Data Logger
- Storage: Removable flashcard (1.0 GB)
- Reader: USB
Display
- Type: Vacuum Florescent Display (VFD)
- Configuration: 4-line / 20-column
Power Module
- Input: Switch mode power input, 100 - 260 VAC
Sonic Anemometer
- Wind speed: 0 - 60 m/s, 0.01 m/s resolution
- Wind direction: 0 - 359°, 1° resolution
Outdoor Enclosure
- Material: Fibre Reinforced Polycarbonate (FRP)
- Dimensions: 515 x 415 x 230 mm + mountings
- Rating: IP66 (NEMA type 4)
Communication Module Options
- GSM modem: Dualband 900/1800 MHz (excludes SIM)
- RF modem: 433, 900, 1800, 2400 MHz
- Wireless LAN: 802.11
Other Options
- Enclosure heating / cooling modules
- Programmable Logic Controller
- Particulate monitor integration
- Solar power system
Contact Aeroqual for specifications on other options.