Summary

Product Identification

The AQM 60 is an integrated multi-gas monitor capable of delivering high quality data for up to six gases in ambient air environments.

General Specifications

Gas Sensors

  • Ozone (Ultra-low)
    • Range: 0 - 150 ppb
    • Resolution: 1 ppb
  • Ozone (Low)
    • Range: 0 - 500 ppb
    • Resolution: 1 ppb
  • Nitrogen dioxide
    • Range: 0 - 200 ppb
    • Resolution: 1 ppb
  • Carbon monoxide
    • Range: 0 - 100 ppm
    • Resolution: 0.1 ppm
  • Sulphur dioxide
    • Range: 0 - 10 ppm
    • Resolution: 0.01 ppm
  • VOC (Non-Methane Hydrocarbon)
    • Range: 0 - 25 ppm
    • Resolution: 0.1 ppm
  • VOC (Toluene)
    • Range: 0 - 500 ppm
    • Resolution: 1 ppm
  • Hydrogen sulphide
    • Range: 0 - 10 ppm
    • Resolution: 0.01 ppm
  • Ammonia
    • Range: 0 - 100 ppm
    • Resolution: 1 ppm
  • Halogenated hydrocarbons
    • Range: 0 - 500 ppm
    • Resolution: 1 ppm
  • Carbon dioxide (NDIR)
    • Range: 0 - 2000 ppm
    • Resolution: 10 ppm

Contact Aeroqual for other calibrations.

Zero Air Scrubber

  • Type: Triple media (Hopcalite, activated carbon and alumina)
  • Zero calibration: Programmable or external activation

Pump

  • Type: Brushless rotary vane

Sample Gas Line Materials

  • Materials: PFA Teflon, PTFE, Kynar

Connections

  • Air inlet / exhaust: 3 mm Kynar barb
  • Communications: 4-way M12 female

Communications

  • Protocol: RS232 or RS485 (analog 0-5 V outputs optional)
  • Data transfer: Polling or pushing
  • Data sampling rate: 2 minutes

Power Requirements

  • Voltage: 24VDC / 1A

Enclosure (Internal)

  • Material: Fibre Reinforced Polycarbonate (FRP)
  • Dimensions: 361 x 254 x 165 mm
  • Weight: < 10 Kg

Approvals

  • Part 15 of FCC Rules
  • EN 61000-6-3: 2001
  • EN 61000-6-1: 2001

Optional Modules

Temperature & Humidity

  • Temperature sensor: -20°C - 100°C, 0.01°C resolution
  • Relative humidity sensor: 0 - 100% RH, 1% resolution

Data Logger

  • Storage: Removable flashcard (1.0 GB)
  • Reader: USB

Display

  • Type: Vacuum Florescent Display (VFD)
  • Configuration: 4-line / 20-column

Power Module

  • Input: Switch mode power input, 100 - 260 VAC

Sonic Anemometer

  • Wind speed: 0 - 60 m/s, 0.01 m/s resolution
  • Wind direction: 0 - 359°, 1° resolution

Outdoor Enclosure

  • Material: Fibre Reinforced Polycarbonate (FRP)
  • Dimensions: 515 x 415 x 230 mm + mountings
  • Rating: IP66 (NEMA type 4)

Communication Module Options

  • GSM modem: Dualband 900/1800 MHz (excludes SIM)
  • RF modem: 433, 900, 1800, 2400 MHz
  • Wireless LAN: 802.11

Other Options

  • Enclosure heating / cooling modules
  • Programmable Logic Controller
  • Particulate monitor integration
  • Solar power system

Contact Aeroqual for specifications on other options.


Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.