Datasheet summary
IQM 60
Engineering summary from PDF text extraction for IQM 60. Verify every value with the OEM datasheet.
Summary
Product identification
The IQM 60 is an integrated multi-gas indoor air quality monitor.
Features
- Analytic GSS Technology® / PID / NDIR
- Multi-gas monitoring (up to six gases)
- Temperature and humidity sensing
- Integrated particle monitor (PM 2.5 & PM 10) option
- Active air sampling
- High quality data in real-time
- RS 232 / USB serial communications
- On-board & remote data logging
- Wireless communication options
- PC data logging software
- User-defined calibration
- Quiet operation
- Low maintenance
- Portable
Applications
- Office environments
- Commercial buildings
- School buildings
- Airports
- Shopping malls
- Domestic monitoring
- Air quality engineering analysis
General Specifications
Sensors
| Sensor Type | Range | Resolution |
|---|---|---|
| Ozone | 0 - 500 ppb | 1 ppb |
| Carbon monoxide | 0 - 100 ppm | 0.1 ppm |
| VOC (Non-Methane Hydrocarbon) | 0 - 25 ppm | 0.1 ppm |
| VOC (Isobutylene) | 0 - 500 ppm | 1 ppm |
| Carbon dioxide (NDIR) | 0 - 5000 ppm | 10 ppm |
| PID (Isobutylene) | 0.01 - 20 ppm | 10 ppb |
| Temperature | -20 ºC - 100 ºC | 0.01ºC |
| Relative Humidity | 0 - 100% | 1.0% |
Contact Aeroqual for other calibrations.
Particulate Monitoring Option
- Technology: Light scattering
- Options: PM 2.5 or PM 10
- Calibration: Zero and span calibration using provided software
- Sampling: Active via fan
Communications
- RS232: DB 9 female
- USB: Mini USB
- Data sampling rate: User defined
Power requirements
- 12VDC
Enclosure
- Materials: Aluminium and powder coated steel
- Dimensions: 236mm W x 132mm H x 278 mm D
- Weight: 2.1 Kg (IQM 60 Monitor)
Data logger module
- Storage: Removable flashcard
- Capacity: 1.0 GB
- Interface: USB (Flashcard reader)
Display
- Type: Vacuum Florescent Display (VFD)
- Configuration: 4-line / 20-column
12VDC Power supply
- Type: Switch mode power input
- Input voltage: 100 - 260 VAC
Communication module options
- GSM modem: Dualband 900/1800 MHz (excludes SIM)
- Wireless LAN: 802.11
Approvals
- Part 15 of FCC Rules
- EN 61000-6-3: 2001
- EN 61000-6-1: 2001
Accessories
- Calibration Kit
- Calibration gas humidifier
Contact Aeroqual for details.
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.