
Datasheet summary
Titromat TH
Engineering summary from PDF text extraction for Titromat TH. Verify every value with the OEM datasheet.
Summary
Product identification
Titromat® TH is used for automatically determining and monitoring the carbonate hardness for high hardness measuring ranges.
Application
- drinking water production and supply
- raw water monitoring
Operating limits
Measuring range
- 2.5–50.0 °dH (resolution: 2.5)
Feed water
Operating pressure
- 1 to 8 bar (15 to 116 psi)
- 0.3 to 1 bar (5 to 15 psi), after removing of the valve body out of the regulator/filter housing
Water inlet
- Opaque hose with 6 mm external diameter / 4 mm internal diameter
Water outlet
- Hose with 6 mm external diameter / 4 mm internal diameter
Water temperature
- 10 to 40 °C (50 to 104 °F)
Electrical
- Power supply: 230–240 VAC, 115 VAC, 24 VAC (all 50–60 Hz)
- Power consumption: max. 30 VA
- Protection class: I
- Degree of protection: IP 65
Mechanical / hydraulic
- Dimensions (W x H x D): 380 x 480 x 280 mm
- Weight: approx. 9.5 kg
- Ambient temperature: 10–45 °C (50 - 104 °F)
- Menu languages: German, English, French, Italian (others upon request)
Disclaimer: Extraction may miss figures, footnotes, or revisions; contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.