Summary

Product identification

DULCOTEST® sensors for bromine measurement are available for various applications.

Sensor types

  • BCR 1-mA: For total available bromine from BCDMH and other oxidative-acting bromine organic disinfectants, and total chlorine. Suitable for contaminated water and high pH values (up to 9.5). Designed for controllers with mA input.
  • BRE 3-CAN-P: For free and combined bromine, also for use with slightly contaminated water. For use on controllers with CAN-bus connection.
  • CBR 1-mA: For free chlorine and bromine, and combined bromine (bromamines). Suitable for contaminated water and high pH values (up to 9.5). For use with controllers with 4-20 mA input.
  • CBR 1-CAN-P: For free chlorine and bromine, and combined bromine (bromamines). Suitable for contaminated water and high pH values (up to 9.5). For use on controllers with CAN-bus connection.

Operating limits

General

  • Temperature: 5 to 45 °C (BCR 1-mA, BRE 3-CAN-P) or 1 to 40 °C (CBR 1-mA, CBR 1-CAN-P).
  • Max. pressure: 1.0 bar (BCR 1-mA, CBR 1-mA, CBR 1-CAN-P) or 3.0 bar (BRE 3-CAN-P).
  • pH range: 5.0 to 9.5 (BCR 1-mA) or 5 to 9.5 (CBR 1-mA, CBR 1-CAN-P). BRE 3-CAN-P notes pH dependence; sensitivity is reduced if pH changes from 7 to 8 by approx. 10% for DBDMH/free bromine and approx. 25% for BCDMH.
  • Intake flow: 30 to 60 l/h.

Feed water

Resistance

Sensors are designed to resist:

  • Dirt films, biofilms, surfactants
  • Salts, acids, alkalis

Product water

Measured variables

  • BCR 1-mA: Total available bromine from BCDMH (1-bromo-3-chloro-5,5-dimethylhydantoin) and N-bromamido-sulphonate, total chlorine.
  • BRE 3-CAN-P: Total available bromine from DBDMH (1,3-dibromo-5,5-dimethyl-hydantoin), BCDMH (1-bromo-3-chloro-5,5-dimethyl-hydantoin), free bromine (HOBr, OBr⁻).
  • CBR 1-mA & CBR 1-CAN-P: Free chlorine, free bromine, combined bromine (bromamines), DBDMH (1,3-dibrom-5,5-dimethyl-hydantoin).
  • For CBR 1-mA and CBR 1-CAN-P: Measuring range is based on chlorine. When measuring bromine, the lower and upper limit of the measuring range are increased by the factor 2.25.

Reference methods

  • DPD4 (BCR 1-mA)
  • DPD1 for DBDMH and free bromine; DPD4 for BCDMH (BRE 3-CAN-P)
  • DPD1 (CBR 1-mA, CBR 1-CAN-P)

Electrical

Supply voltage

  • BCR 1-mA & CBR 1-mA: 16 to 24 V DC (two-wire)
  • BRE 3-CAN-P & CBR 1-CAN-P: Via CAN interface (11 to 30 V or 11–30 V DC).

Output signal

  • BCR 1-mA & CBR 1-mA: 4 to 20 mA (measuring range, temperature-compensated, uncalibrated, not electrically isolated).
  • BRE 3-CAN-P & CBR 1-CAN-P: Digital (CANopen, uncalibrated, temperature-compensated, galvanically isolated for CBR 1-CAN-P).

Mechanical / hydraulic

Sensor fitting

  • DGM, DLG III (or DLG II for CBR 1-mA and CBR 1-CAN-P).

Installation

  • Bypass: open sample water outlet.