Datasheet summary
DULCOTEST DO
Engineering summary from PDF text extraction for DULCOTEST DO. Verify every value with the OEM datasheet.
Summary
Product identification
- Product line: DULCOTEST® sensors for dissolved oxygen
- Models: DO 3-mA, DO 2-mA
Operating limits
DO 3-mA
- Temperature: 0 … 50 °C
- Max. pressure: 2.0 bar
- Supply voltage: 18...30 V DC
DO 2-mA
- Temperature: 0 … 50 °C
- Max. pressure: 1.0 bar
- Supply voltage: 12...30 V DC
- Intake flow: Minimum: 0.05 m/s
Feed water
DO 3-mA
- Measuring principle: Optical (measurement of the relaxation time of a pulsed fluorescence beam)
- Measuring ranges: 0.10…20.0 mg/l (Order no. 1094609)
- Measured variable: Dissolved oxygen
- Calibration: On atmospheric oxygen or by reference measurement in the process water
- Measuring accuracy: ±0.1 mg/l
- Response time sensor t90: < 60 s at 25 °C from air to nitrogen
- Temperature correction: Integrated Pt1000, fed to the outside
- Resistance to: Carbon dioxide (CO₂), hydrogen sulfide (H₂S), sulfur dioxide (SO₂), ethylene oxide, gamma sterilization, contaminated water.
- Interference by: Oxidants (e.g., chlorine, chlorine dioxide, ozone) and organic solvents (e.g., chloroform, toluene, acetone).
DO 2-mA
- Measuring principle: Amperometric, 2 electrodes, membrane-covered, encapsulated transducer integrated in ball float
- Measuring ranges: 0.05…10.0 mg/l (Order no. 1020533)
- Measured variable: Dissolved oxygen
- Calibration: On oxygen or by reference measurement in the process water
- Measuring accuracy: ±0.05 mg/l
- Response time sensor t90: 22 s
- Temperature correction: Not specified (integrated temperature measurement compensates for influence)
- Resistance to: Contaminated water.
- Interference by: Oxidants (e.g., chlorine, chlorine dioxide, ozone), organic solvents (e.g., chloroform, toluene, acetone), and hydrogen sulfide (H₂S).
Product water
DO 3-mA
- Output signal: 4…20 mA assigned to the measuring range, temperature-corrected, calibrated and galvanically isolated.
- Displayed units: [ppm] and [% oxygen saturation] (with compatible measuring and control equipment)
DO 2-mA
- Output signal: 4…20 mA measuring range calibrated, temperature-corrected and electrically isolated.
Electrical
DO 3-mA
- Electrical connection: Fixed cable, 10 m
- Enclosure rating: IP 68
DO 2-mA
- Electrical connection: Fixed lead, 10 m
- Enclosure rating: IP 68
Mechanical / hydraulic
DO 3-mA
- Construction: Rod-shaped
- Process integration:
- Immersion by immersion pipe (customer-provided PVC, d40/DN 32) using immersion pipe adapter and 45° angle (included).
- Installation into ProMinent bypass fittings, type DGMa or DLG III (with specific mounting kits).
DO 2-mA
- Process integration: Integrated in a floating ball with a Venturi cleaning function. Supplied with adapter for connection to PVC pipes (outside diameter: 50 mm) and railing bracket.
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.