Back to DuPont
DuPont logo

Datasheet summary

AmberChrom XT20

PDF datasheet mirror for AmberChrom XT20 (DuPont). Verify with OEM before design.

Summary

Product identification

AmberChrom™ XT20 Chromatography Resin

Description

AmberChrom™ XT20 is a macroporous, 20-µm, rigid, insoluble polystyrene-divinylbenzene polymer used for high-value reversed-phase chromatography (RPC). It is designed for the cost-effective separation of proteins, peptides, and oligonucleotides in downstream purification and polishing steps for pharmaceutical applications.

Applications

  • Capture, separation, and purification of proteins, peptides, and oligonucleotides.

Typical Properties

Physical Properties

  • Copolymer: Styrene-divinylbenzene
  • Matrix: Macroporous
  • Type: Adsorbent
  • Physical Form: White, opaque, spherical beads
  • Nitrogen BET Surface Area: 560 – 580 m²/g
  • Total Pore Volume: 0.61 mL/mL
  • Average Pore Diameter: 300 Å

Chemical Properties

  • Functional Group: None
  • Shipping Form: Dry
  • Chemical Resistance: Insoluble in dilute solutions of acids or bases and common solvents: IPA, ACN, MeOH

Particle Size

  • Particle Diameter, mean: 20 µm
  • Particle Size Distribution: ≥ 85% between 15 – 30 µm

Stability

  • Swelling (in solvent):
    • Water: 0%
    • Methanol: 1%
    • Isopropanol: 1%
    • Acetone: 2%
    • Toluene: 2%

Suggested Operating Conditions

  • Temperature Range: 4 – 60°C (39 – 140°F)
  • pH Range: 1 – 14
  • Pressure Range: ≤ 60 bar (870 psi)

Regulatory Status

DuPont can provide regulatory support for AmberChrom™ XT20 Chromatography Resin to end users under confidentiality, upon request.