Summary

Product identification

AmberLite™ FPA22 Ion Exchange Resins are macroporous, Type II strong base anion resins designed for mixed bed polishing in sweetener applications.

Applications

  • Sweetener mixed bed polishing

Typical Properties

Physical Properties

  • Copolymer: Styrene-divinylbenzene
  • Matrix: Macroporous
  • Type: Strong base anion, Type II
  • Functional Group: Dimethylethanolamine
  • Physical Form: White to yellow, opaque, spherical beads

Chemical Properties

  • Ionic Form as Shipped:
    • OH⁻
    • Cl⁻
  • Total Exchange Capacity: ≥ 1.2 eq/L (Cl⁻ form)
  • Water Retention Capacity:
    • 46 – 56% (Cl⁻ form)
    • 48 – 56%
  • Particle Size:
    • < 300 µm: ≤ 2% (OH⁻ form), ≤ 1% (Cl⁻ form)
    • 1180 µm: ≤ 5% (OH⁻ form), ≤ 2% (Cl⁻ form)

  • Stability (Whole Beads): ≥ 95%
  • Swelling (Cl⁻ → OH⁻): 12%
  • Density:
    • Particle Density: 1.1 g/mL
    • Shipping Weight: 800 g/L

Suggested Operating Conditions

  • Maximum Operating Temperature (OH⁻ form): 46°C (115°F)
  • pH Range: 0 – 14
  • Bed Depth, min.: 910 mm (3.0 ft)
  • Flowrates:
    • Service: 3 – 5 BV*/h
    • Fast Rinse (if applicable): 2 – 10 BV/h
  • Contact Time:
    • Regeneration: ≥ 30 – 45 minutes
    • Displacement Rinse: ≥ 30 – 45 minutes
  • Total Rinse Requirement: 3 – 6 BV
  • Regenerant:
    • NaOH†:
      • Concentration: 4%
      • Level: 64 – 80 kg/m³ (4 – 5 lb/ft³)
      • Temperature, max.: 46°C (115°F)
    • Na₂CO₃:
      • Concentration: 7%
      • Level: 80 – 96 kg/m³ (5 – 6 lb/ft³)
      • Temperature, max.: 46°C (115°F)

* 1 BV (Bed Volume) = 1 m³ solution per m³ resin or 7.5 gal per ft³ resin † NaOH is recommended.

Hydraulic Characteristics

  • Backwash expansion is shown in Figure 1 as a function of backwash flowrate at 25°C (77°F).
  • Pressure drop data as a function of service flowrate and viscosity is shown in Figure 2.