Back to DuPont
DuPont logo

Datasheet summary

AmberLite FPA90RF Cl

PDF datasheet mirror for AmberLite FPA90RF Cl (DuPont). Verify with OEM before design.

Summary

Product identification

  • Product Name: AmberLite™ FPA90RF Cl Ion Exchange Resin
  • Description: Food-grade, Reduced Fines, Styrenic, Macroporous, Strong Base Anion Exchange Resin for Cane Sugar Decolorization
  • Copolymer: Styrene-divinylbenzene
  • Matrix: Macroporous
  • Type: Strong base anion, Type I
  • Functional Group: Trimethylammonium
  • Physical Form: Off-white, opaque, spherical beads
  • Ionic Form as Shipped: Cl⁻

Applications

  • Cane sugar decolorization

Chemical Properties

  • Total Exchange Capacity: ≥ 1.00 eq/L
  • Water Retention Capacity: 58 – 64%

Physical Properties

  • Particle Size:
    • Particle Diameter: 650 – 820 µm
    • Uniformity Coefficient: ≤ 1.5
    • < 300 µm: ≤ 0.1%
    • 1180 µm: ≤ 2.0%

  • Stability:
    • Swelling (Cl⁻ → OH⁻): ~25%
  • Density:
    • Particle Density: 1.050 – 1.080 g/mL
    • Shipping Weight: 700 g/L

Suggested Operating Conditions

  • Maximum Operating Temperature (Cl⁻ form): 80°C (176°F)
  • Bed Depth, min.: 1000 mm (3.3 ft)
  • Flowrates:
    • Service: 2 – 4 BV*/h (or up to 8 BV/h)
    • Sweeten-off: Service flowrate for 1.5 – 2 BV
    • Backwash: See Figure 1 (Hydraulic Characteristics)
    • Regeneration: 2 BV/h
    • Slow Rinse: 2 BV/h
    • Sweeten-on: Service flowrate for 1 BV
  • Contact Time:
    • Regeneration: ≥ 45 – 60 minutes
    • Displacement Rinse: ≥ 60 minutes
  • Total Rinse Requirement: 5 BV
  • Regenerant: NaCl + NaOH
    • Concentration: 10% NaCl | 0.2% NaOH
    • Level (100% basis):
      • Co-current: 180 – 200 kg/m³ (11.3 – 12.5 lb/ft³)
      • Counter-current: 150 kg/m³ (9.4 lb/ft³)
    • Temperature: 25 – 70°C (77 – 158°F)

* 1 BV (Bed Volume) = 1 m³ solution per m³ resin or 7.5 gal solution per ft³ resin

Hydraulic Characteristics

Bed expansion as a function of backwash flowrate and temperature is shown in Figure 1 (for temperatures 5 – 60°C or 41 – 140°F).

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.